ML20203A778

From kanterella
Revision as of 05:43, 1 January 2021 by StriderTol (talk | contribs) (StriderTol Bot change)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards Insp Rept 99900824/86-01 on 860602-06
ML20203A778
Person / Time
Issue date: 07/15/1986
From: Heishman R
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To: Rachel Johnson
SOR, INC. (STATIC O-RING)
Shared Package
ML20203A783 List:
References
REF-QA-99900824 NUDOCS 8607170311
Download: ML20203A778 (2)


Text

^

j nuby UNITED STATES

& $ NUCLEAR REGULATORY COMMISSION y g L j WASHINGTON, D. C. 20555

\ ***#

/ July 15, 1986 Docket No. 9990082a86-01 Static 0 Ring ATTN: Mr. R. Johnson Vice President & General Manager 11705 Blackbob Road Olathe, Kansas 66061 Gentlemen:

This refers to the inspection conducted by K. R. Naidu of this office on June 2-6, 1986, of your facility at Olathe, Kansas and to the discussions of our findings with you and members of your staff at the conclusion of the inspection. The enclosed inspection report documents the observations made during the disassembly, on June 25, 1936, of one of the differential pres-sure switches which malfunctioned at the LaSalle County Station Unit 2.

The purpose of this inspection was to determine whether you have effectively itnplemented a quality assurance program meeting the requirements of 10 CFR 50 Appendix B with regard to the manufacture of pressure and level switches and if you have an effective procedure to report potential defects in accordance with the requirements of 10 CFR Part 21. Areas examined during the inspection and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.

In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room.

Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely, we -

8607170311 860715 Pobert F. Peishman, Chief PDR GA999 EMVSORNG Vendor Program Branch 99900826 PDR Division of Quality Assurance, Vendor and Technical Training Center Programs Office of Inspection and Enforcement

Enclosure:

Inspection Report No. 99900826/86-01

i r, .

Static 0 Ring July 15, 1986 DISTRIBU" ION:

ipre.TE 5Py

.VPB"Reiding DQAVT Reading JStone EMerschoff KNaidu LParker JTaylor BGrimes e

  • See previous page for concurrences. /

VPB:00AVT SC/VPB:00AVT BC/ . QAVT KNaidu:tt* EMerschof f* RFHeip'r.an 07/10/86 07/11/86 g//)/86 i\

.)