ML20206D867

From kanterella
Revision as of 09:32, 11 December 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards Insp Rept 99901085/87-01 on 870309-11 & Notice of Nonconformance.Descriptions & Dates of Actions Taken, Underway or Planned to Correct Failures,Including Absence of Complete Qualification Records for NDE Personnel Requested
ML20206D867
Person / Time
Issue date: 04/08/1987
From: Merschoff E
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
To: Basile G
UNITED STATES TESTING CO., INC.
Shared Package
ML20206D872 List:
References
REF-QA-99901085 NUDOCS 8704130448
Download: ML20206D867 (4)


Text

.

/ 'o UNITED STATES

-  ! o NUCLEAR REGULATORY COMMISSION g i WASHINGTON, D, C. 20006

\ *****

/

April 8, 1987 Docket No. 99901085/87-01 United States Testing Company, Incorporated Unitech Services Group ATTN: Mr. Gene Basile President 1415 Park Avenue Hoboken, New Jersey 07030 Gentlemen:

This refers to the inspection conducted by Mr. James T. Conway of this office on March 9-11, 1987, of your facility at Hoboken, New Jersey and to the discussions of our findings with Mr. William Coles and members of your staff at the conclu-sion of the inspection.

The purpose of this inspection was to conduct an evaluation of the implementation of your 0A program in the areas of reporting of defects and nondestructive examination (NDE). Areas examined during the inspection and our findings are discussed in the enclosed report. Within these areas, the inspection consisted of an examination of procedures and representative records, interviews with personnel, and observations by the inspector.

Durino the inspection it was found that the implementation of your 0A procram failed to meet certain NRC requirements. Significant items included failures to have complete qualification records for NDE personnel and to use a Level III individual or a designated representative to administer and grade examinations.

The specific findings and references to the pertinent requirements are identified in the enclosures to this letter.

Please provide us within 30 days from the date of this letter a written statement containing: (1) a description of steps that have been or will be taken to correct these items; (2) a description of steps that have been or will be taken to prevent recurrence; and (3) the dates your corrective actions and preventive measures were or will be completed. Consideration may be given to extending your response time for good cause shown.

The response requested by this letter is not subject to the clearance procedures of the Office of Management and Budget as reauired by the Paperwork Reduction Act of 1980, PL 96-511. In accordance with 10 CFR 2.790 of the Connission's regulations, a copy of this letter and the enclosed inspection report will be placed in the NRC's Public Document Room.

8704130448 870408 PDR GA999 EECUSTES 99901085 PDR

-United States Tssting Company, April 8, 1987 Incorporated Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely,

$$ gird! Signad by Ellis W. Uhr::110E Ellis W. Merschoff, Acting Chief Vendor Program Branch Division of Quality Assurance, Vendor and Technical Training Center Programs Office of Inspection and Enforcement

Enclosures:

1. Appendix A-Notice of Nonconformance
2. Appendix B-Inspection Report No. 99901085/87-01 DISTRIBUTION:

RIOS: Code:IEiO99 VPB'Rsading DQAVT Reading JTaylor BGrimes EMerschoff EBaker JStone JConway (2)

LParker(2)

RScarano, RV GSjoblom JJoyner, RI  ;

l ,

1 i

  • See previous pa e ,o concurre .

)

VPB:DQAVT SC VP :DQAVT PB:DQAVT JConway:tt* Egaker tWerschoff 04/01/87 ///7/87 4 / 7/87 i

.i s

United States Testing Company. April 8, 1987 Incorporated Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely, y( -: - - - ,

E:2. .?.

Ellis W. Merschoff, Acting Chief Vendor Program Branch Division of Quality Assurance, Vendor and Technical Training Center Programs Office of Inspection and Enforcement

Enclosures:

1. Appendix A-Notice of Nonconformance
2. Appendix B-Inspection Report No. 99901085/87-01 DISTRIBUTION:

RIDS Code IE:09 VPB Reading 00AVT Reading JTaylor BGrimes EMerschoff EBaker JStone JConway LParker 2)((2)

RScarano, RV GSjoblom JJoyner, RI

  • See previous pa e f concurre VPB:D0AVT C/VPB:00AVT i PB:DOAVT JConway:tt* EQaker EPerschoff 04/01/87 y/]/87 4/f/87

United States Testing Company, April 8,1987 Incorporated Should you have any questions concerning this inspection, we will be pleased to discuss them with you.

Sincerely, EllisW.Nerschoff cting Chief Vendor Program Br ch Division of Qual y Assurance, Vendor and Technical Training Center Programs Office of Inspection and Enforcement

Enclosures:

1. Appendix A-Notice of Nonconformance
2. Appendix B-Inspection Report No. 99901085/87-01 J

$