Responds to NRC 840109 Ltr Re Violations Noted in IE Insp Rept 50-483/83-30.Corrective Actions:Revised Procedure GS-22, Radiological Environ Monitoring Program, Defining Program Mgt Responsibilities
ML20080G374
Person / Time
Site: Callaway Ameren icon.png
Issue date: 01/23/1984
From: Schnell D
UNION ELECTRIC CO.
To: Paperiello C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20080G369 List:
References
ULNRC-737, NUDOCS 8402130370
Download: ML20080G374 (1)


Text

C

4. N UNION ELECTRIC COM PANY

$ 908 GRATIOT STREET ST. LOUIS, MISSOURI o o ~,co ,. .c.,~ .u. January 23, 1984 "'R'"*.^o."/.**'

o.,.....

. . . . . . . . .r.too... m.. l Mr. C. J. Paperiello Emergency Preparedness and Radiological Safety Branch U.S. Nuclear Regulatory Commission Region III 799 Roosevelt Road. l Glen Ellyn, IL 60137 l

Dear Mr. Paperiello:

ULNRC-7 37 INSPECTION REPORT NO. 50-483/83-30 (DRMSP)

This reply is in response to your letter of January 9, 1984 which transmitted the report of the inspection conducted at Callaway Plant, Unit 1 during the period of December 13, 1983 to December 15, 1983. Our response to the open item listed within the body of Inspection Report Number 50-483/83-30 (DRMSP) is presented below.

None of the material in the inspection report or in this response is considered proprietary by Union Electric Company.

(50 483/83-07-05) OPEN ITEM Finalize procedure QS-22 defining REMP management responsibilities. This procedure is under review by the licensee's management and has not been approved as yet. This item will remain open, pending licensee approval of this procedure.

RESPONSE

Please find enclosed the approved procedure QS-22 titled

" Radiological Environmental Monitoring Program."

If you have any questions regarding this response or if additional information is r= quired, please let me know.

Very truly yours Mh & Ab Donald F. Schnell BFH/lw Enclosures cc: Dr. M. J. Oestmann, NRC Region III Mr. J. E. Konklin, NRC Region III NRC Resident Inspector, Callaway Plant g 3g Missouri Public Service Commission 8402130370 840200 PDR ADOCK 0500048,2