Interim Deficiency Rept Re Defective Scram Accumulators on Control Rod Drive in Hydraulic Control Units.Initially Reported on 821117.Accumulator Assemblies Sent to GE for Exam & Replacement.Next Rept Scheduled for 830415
ML20064K851
Person / Time
Site: Fermi 
Issue date: 01/28/1983
From: Wells D
DETROIT EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
10CFR-050.55E, 10CFR-50.55E, EF2-61206, NUDOCS 8302150029
Download: ML20064K851 (1)


Text