ML20064K851

From kanterella
Jump to navigation Jump to search
Interim Deficiency Rept Re Defective Scram Accumulators on Control Rod Drive in Hydraulic Control Units.Initially Reported on 821117.Accumulator Assemblies Sent to GE for Exam & Replacement.Next Rept Scheduled for 830415
ML20064K851
Person / Time
Site: Fermi 
Issue date: 01/28/1983
From: Wells D
DETROIT EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
10CFR-050.55E, 10CFR-50.55E, EF2-61206, NUDOCS 8302150029
Download: ML20064K851 (1)


Text

Donald A. Wetts w nacc oaa W An u a f 31 h 237 MU Edison Edis!"=

January 28, 1983 EF2-61206 k3tl Mr. James G. Keppler, Regional Administrator Region III U.S. Nuclear Regulatory Comnission 799 Roosevelt Road Glen Ellyn, Illinois 60137

Subject:

Report of 10CFR50.55(e) Item on Control Rod Drive - Hydraulic Con-trol Units - Scram Accumulators (#80)

Dear Mr. Keppler:

On November 17, 1982, Detroit Edison's Mr. D. Ferencz, Acting Supervisor -

Construction Quality Assurance, telephoned Mr. P.M. Byron of NRC Region III to report a potential problem with the Control Rod Drive (CAD) - Hydraulic Control Units (HCU) - Scram Accumulators at the Fermi 2 site.

Daring disassembly of the accumulators, cracks and pitting of the chrome plating were found in the end caps. Corrosion products were also found in the accumulators. All one hundred and eighty five (185) accumulator assem-blies have been sent to General Electric's facility in Wilmington, North Carolina, for further examination and possible replacement of defective ccxn-ponents.

Another report on this item, either interim or final, is scheduled to be sent on or before April 15, 1983. If you have questions concerning this matter, please contact Mr. G.M. Trahey, Assistant Director - Project Qual-ity Assurance.

Very truly yours, p Y

DAW /DF/pn cc: Mr. Richard DeYoung, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Ccxunission Washington, D.C.

20555 Mr. Bruce Little, Senior Resident Inspector bI r

D ghway Newport, Michigan 48166

,/ )

8302150029 830128 gDRADOCK05000 7g 1.