ML19210D670

From kanterella
Revision as of 03:10, 24 January 2020 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Forwards LERs 79-138/01T-0 & 79-143/01T-0
Date released: 08/12/2019 Download: ML19210D670


LER 79-143/01T-0:on 791109,fuel Vendor Identified Potential Problem Affecting Temp of Large Break LOCA-ECCS Evaluation Model.Caused by Erroneous Fuel Burst Calculations.Study in Progress for Peak Clad Temp
ML19210D687
Person / Time
Site: North Anna Dominion icon.png
Issue date: 11/21/1979
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19210D687 (2)
LER 79-138/01T-0:on 791108,Westinghouse Identified Potential Failure in Circuit Reactor Trip Breaker for P-4 Permissive W/Engineered Safety Features Actuation.Caused by Design Failure.Reanalysis in Progress
ML19210D677
Person / Time
Site: North Anna Dominion icon.png
Issue date: 11/21/1979
From: Cartwright W
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19210D677 (2)
Forwards LERs 79-138/01T-0 & 79-143/01T-0
ML19210D668
Person / Time
Site: North Anna Dominion icon.png
Issue date: 11/21/1979
From: Stallings C
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19210D668 (1)