Interim Deficiency Rept Re Rod Drop Analysis.Westinghouse Notified NRC of Deficiency on 791115.Meeting Held by NRC & Westinghouse.Forwards Westinghouse 791115 Ltr.Final Rept Will Be Issued When Westinghouse Relays Corrective Action
Date released: 09/27/2019 Download: ML19256G241


Confirms Westinghouse 791115 Telephone Notification Re Rod Drop Analysis.Sar Analysis May Not Represent Most Limiting Assumption for Credible Single Failure.Forwards Info Identifying Affected Westinghouse Plants.W/O Encl
ML19256G243
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 11/15/1979
From: Anderson T
WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP.
To: STELLO V
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE)
References
Download: ML19256G243 (2)
Interim Deficiency Rept Re Rod Drop Analysis.Westinghouse Notified NRC of Deficiency on 791115.Meeting Held by NRC & Westinghouse.Forwards Westinghouse 791115 Ltr.Final Rept Will Be Issued When Westinghouse Relays Corrective Action
ML19256G240
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 12/19/1979
From: Crews E
SOUTH CAROLINA ELECTRIC & GAS CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML19256G240 (2)