ML052500242
From kanterella
Revision as of 15:49, 8 December 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Letter Sequence Other | |
---|---|
TAC:MC6955, (Open) | |
Initiation
Administration Questions
| |
MONTHYEARML0525002422005-09-0606 September 2005
[Table View]Technical Specifications, Revises the TSs in Response to an Application Requesting a One-Time Extension of the Surveillance Interval for the Reactor Vessel Internal Vent Valves Project stage: Other ML0519303402005-09-0606 September 2005 License Amendment, Revises the TSs in Response to an Application Requesting a One-Time Extension of the Surveillance Interval for the Reactor Vessel Internal Vent Valves Project stage: Other 2005-09-06 |
ML052500242 | |
Person / Time | |
---|---|
Site: | Davis Besse |
Issue date: | 09/06/2005 |
From: | Macon W NRC/NRR/DLPM/LPD3 |
To: | Bezilla M FirstEnergy Nuclear Operating Co |
Macon W, NRR/DLPM,415-3965 | |
References | |
TAC MC6955 | |
Download: ML052500242 (1) | |
Similar Documents at Davis Besse | |
---|---|
Category:Technical Specifications
MONTHYEARML22210A0102022-09-16016 September 2022
[Table view]Energy Harbor Fleet- Issuance of Amendments Regarding Adoption of TSTF 554, Revise Reactor Coolant Leakage Requirements ML21075A1132021-04-16016 April 2021 Issuance of Amendment Nos. 311, 200, and 302 to Incorporate the Applicable Standard Technical Specification 5.2.2, Unit Staff, Into the Technical Specifications ML20280A8272020-11-0303 November 2020 Issuance of Amendment No. 301 to Relocate Specific Surveillance Frequencies to a Licensee-Controlled Program ML20213C7262020-08-24024 August 2020 Issuance of Amendment No. 300 to Revise the Containment Leakage Rate Testing Program ML19100A3062019-06-21021 June 2019 Issuance of Amendment No. 298 to Adopt National Fire Protection Association Standard 805 ML16342C9462017-01-12012 January 2017 Issuance of Amendment Revising Emergency Action Level Scheme ML16040A0842016-06-0707 June 2016 FENOC, Beaver Valley Power Station, Unit Nos. 1 and 2; and Davis-Besse Nuclear Power Station, Unit No. 1 - Issuance of Amendments Revision to Technical Specification 5.3.1, Unit Staff Qualifications ML16083A4812016-04-27027 April 2016 Issuance of Amendment Revising Emergency Diesel Generator Minimum Voltage and Frequency Acceptance Criteria ML15251A0462015-10-20020 October 2015 Issuance of Amendment Revising Containment Spray Nozzle Surveillance Requirement L-14-407, Request to Amend Technical Specification 5.5.15, Containment Leakage Rate Testing Program2014-12-19019 December 2014 Request to Amend Technical Specification 5.5.15, Containment Leakage Rate Testing Program ML14023A7662014-03-31031 March 2014 Issuance of Amendment Related to Steam Generator Inventory Change (TAC No. MF0536)(L-13-040) L-13-040, License Amendment Request for Proposed Revision of Technical Specification (TS) 3.4.17, Steam Generator (SG) Tube Integrity; TS 3.7.18, Steam Generator Level; TS 5.5.8, Steam Generator Program; and TS 5.6.6..2013-01-18018 January 2013 License Amendment Request for Proposed Revision of Technical Specification (TS) 3.4.17, Steam Generator (SG) Tube Integrity; TS 3.7.18, Steam Generator Level; TS 5.5.8, Steam Generator Program; and TS 5.6.6.. L-12-070, License Amendment Request to Revise Emergency Diesel Generator Minimum Voltage Surveillance Requirements, and Add Figure Axis Labels2012-05-23023 May 2012 License Amendment Request to Revise Emergency Diesel Generator Minimum Voltage Surveillance Requirements, and Add Figure Axis Labels ML1208604472012-04-18018 April 2012 Issuance of Amendment Modification of the Special Visual Inspection Requirement of TS 5.5.8 Steam Generator Program L-11-097, License Amendment Request to Modify the Special Visual Inspection Requirements of Technical Specification 5.5.8, Steam Generator (SG) Program.2011-05-20020 May 2011 License Amendment Request to Modify the Special Visual Inspection Requirements of Technical Specification 5.5.8, Steam Generator (SG) Program. L-09-025, ISFSI, and Perry, Application for Technical Specification (TS) Change for Adoption of TSTF-511 Revision 0, Eliminate Working Hour Restrictions from TS 5.2.2 to Support Compliance with 10 CFR Part 26.2009-03-25025 March 2009 ISFSI, and Perry, Application for Technical Specification (TS) Change for Adoption of TSTF-511 Revision 0, Eliminate Working Hour Restrictions from TS 5.2.2 to Support Compliance with 10 CFR Part 26. ML0822706662008-08-0707 August 2008 Improved Technical Specification Conversion License Amendment Request, Volume 10, Revision 1, ITS Section 3.5, Emergency Core Cooling Systems L-08-240, Improved Technical Specification Conversion License Amendment Request, Volume 14, Revision 1, ITS Section 3.9, Refueling Operations2008-08-0707 August 2008 Improved Technical Specification Conversion License Amendment Request, Volume 14, Revision 1, ITS Section 3.9, Refueling Operations ML0822706612008-08-0707 August 2008 Improved Technical Specification Conversion License Amendment Request, Volume 1, Revision 1, Application of Selection Criteria to the Dbnps Technical Specifications ML0822706622008-08-0707 August 2008 Improved Technical Specification Conversion License Amendment Request, Volume 2, Revision 1, Generic Determination of No Significant Hazards Consideration and Environmental Assessment ML0822706672008-08-0707 August 2008 Improved Technical Specification Conversion License Amendment Request, Volume 16, Revision 1, ITS Chapter 5.0, Administrative Controls ML0822706702008-08-0707 August 2008 Improved Technical Specification Conversion License Amendment Request, Volume 13, Revision 1, ITS Section 3.8, Electrical Power Systems ML0822706692008-08-0707 August 2008 Improved Technical Specification Conversion License Amendment Request, Volume 12, Revision 1, ITS Section 3.7, Plant Systems ML0822706652008-08-0707 August 2008 Improved Technical Specification Conversion License Amendment Request, Volume 8, Revision 1, Section 3.3 - Instrumentation ML0822706642008-08-0707 August 2008 Improved Technical Specification Conversion License Amendment Request, Volume 4, Revision 1, ITS Chapter 2.0, Safety Limits ML0822706632008-08-0707 August 2008 Improved Technical Specification Conversion License Amendment Request Volume 3, Revision 1, ITS Chapter 1.0, Use and Application ML0822706582008-08-0707 August 2008 Supplement to License Amendment Request: Conversion of Current Technical Specifications to Improved Technical Specifications - Volumes 1, 2, 3, 4, 8, 10, 12, 13, 14, and 16 ML0818306382008-06-30030 June 2008 Tech Spec Pages for Amendment 278 Regarding Measurement Uncertainty Recapture Power Uprate ML0826005772008-05-30030 May 2008 Attachment 1, Applicable Portions of the U.S. Nuclear Regulatory Commission (NRC) and Davis-Besse Nuclear Power Station (DBNPS) Improved. Technical Specification (ITS) Conversion Website ML0814804672008-05-16016 May 2008 Improved Technical Specification Conversion License Amendment Request, Volume 7, (Revision 1), Section 3.2 - Power Distribution Limits ML0814804652008-05-16016 May 2008 Improved Technical Specification Conversion License Amendment Request, Volume 5, (Revision 1), Section 3.0 - LCO and SR Applicability ML0814804662008-05-16016 May 2008 Improved Technical Specification Conversion License Amendment Request, Volume 6, (Revision 1), Section 3.1 - Reactivity Control Systems ML0814804682008-05-16016 May 2008 Improved Technical Specification Conversion License Amendment Request, Volume 9, (Revision 1), Section 3.4 - Reactor Coolant System (RCS) ML0814804692008-05-16016 May 2008 Improved Technical Specification Conversion License Amendment Request, Volume 11, (Revision 1), Section 3.6 - Containment Systems ML0814804712008-05-16016 May 2008 Improved Technical Specification Conversion License Amendment Request, Volume 15, (Revision 1), Chapter 4.0 - Design Features L-08-065, Response to Request for Additional Information Regarding Application for License Amendment for Measurement Uncertainty Recapture Power Uprate2008-02-20020 February 2008 Response to Request for Additional Information Regarding Application for License Amendment for Measurement Uncertainty Recapture Power Uprate ML0729601812007-10-17017 October 2007 Technical Specifications, Issuance of Amendment Administrative Control of Penetrations During Refueling ML0722004632007-08-0303 August 2007 Volume 5, Revision 0, Davis-Besse, Unit 1 - Improved Technical Specifications Conversion, ITS Section 3.0 LCO and SR Applicability. ML0722004512007-08-0303 August 2007 Submittal of License Amendment Request No. 06-0003 to Revise Current Technical Specifications to the Improved Technical Specifications ML0722004862007-08-0303 August 2007 Volume 17, Revision 0, Davis-Besse, Unit 1 - Improved Technical Specifications Conversion, Current Technical Specification Markup in CTS Order. ML0722004852007-08-0303 August 2007 Volume 16, Revision 0, Davis-Besse, Unit 1 - Improved Technical Specifications Conversion, ITS Chapter 5.0 Administrative Controls. ML0722004542007-08-0303 August 2007 Volume 1, Revision 0, Davis-Besse, Unit 1 - Improved Technical Specifications Conversion, Application of Selection Criteria. ML0722004562007-08-0303 August 2007 Volume 2, Revision 0, Davis-Besse, Unit 1 - Improved Technical Specifications Conversion, Generic Determination of No Significant Hazards Consideration and Environmental Assessment. ML0722004592007-08-0303 August 2007 Volume 3, Revision 0, Davis-Besse, Unit 1 - Improved Technical Specifications Conversion, ITS Chapter 1.0 Use and Application. ML0722004612007-08-0303 August 2007 Volume 4, Revision 0, Davis-Besse, Unit 1 - Improved Technical Specifications Conversion, ITS Chapter 2.0 Safety Limits. ML0722004832007-08-0303 August 2007 Volume 15, Revision 0, Davis-Besse, Unit 1 - Improved Technical Specifications Conversion, ITS Chapter 4.0 Design Features. ML0722004662007-08-0303 August 2007 Volume 6, Revision 0, Davis-Besse, Unit 1 - Improved Technical Specifications Conversion, ITS Chapter 3.1 Reactivity Control Systems. ML0722004682007-08-0303 August 2007 Volume 7, Revision 0, Davis-Besse, Unit 1 - Improved Technical Specifications Conversion, ITS Section 3.2 Power Distribution Limits. ML0722004702007-08-0303 August 2007 Volume 8, Revision 0, Davis-Besse, Unit 1 - Improved Technical Specifications Conversion, ITS Section 3.3 Instrumentation. ML0722004722007-08-0303 August 2007 Volume 9, Revision 0, Davis-Besse, Unit 1 - Improved Technical Specifications Conversion, ITS Section 3.4 Reactor Coolant System. 2022-09-16 |
Text
REACTOR COOLANT SYSTEM SURVEILLANCE REQUIREMENTS (Continued)
- b. Each internals vent valve shall be demonstrated OPERABLE at least once per 24 months* during shutdown by: I
- 1. Verifying through visual inspection that the valve body and valve disc exhibit no abnormal degradation,
- 2. Verifying the valve is not stuck in an open position, and
- 3. Verifying through manual actuation that the valve is fully open when a force of
< 400 lbs. is applied vertically upward.
- An exception applies for the interval following the March 2003 verification completed during the Thirteenth Refueling Outage. Under this exception, the next performance of this surveillance requirement may be delayed until March 25, 2006.
DAVIS-BESSE, UNIT I 3/4 4-3 1 Amendment No. 23, 95, 165,268