PLA-6119, Proposed Amendment No. 281 to License NPF-14 and No. 251 to License NPF-22: Application for License Amendment and Related Technical Specification Changes to Implement Full-Scope Alternative Source Term in Accordance with 10 CFR 50.67.

From kanterella
Revision as of 13:14, 23 November 2019 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
Jump to navigation Jump to search
Proposed Amendment No. 281 to License NPF-14 and No. 251 to License NPF-22: Application for License Amendment and Related Technical Specification Changes to Implement Full-Scope Alternative Source Term in Accordance with 10 CFR 50.67.
ML062850276
Person / Time
Site: Susquehanna  Talen Energy icon.png
Issue date: 09/29/2006
From: Mckinney B
Susquehanna
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
PLA-6119
Download: ML062850276 (4)


Text

Brltt T. MeKInney PPL Susquehanna, LLC t*"*, 010, Sr. Vice President & Chief Nuclear Officer 769 Salem Boulevard Berwick, PA 18603 Tel. 570.542.3149 Fax 570.542.1504 btmckinney@pplweb.com 1 M

SEP 2 9 2006 U. S. Nuclear Regulatory Commission Attn: Document Control Desk Mail Stop OP 1-17 Washington, DC 20555 SUSQUEHANNA STEAM ELECTRIC STATION PROPOSED AMENDMENT NO. 281 TO LICENSE NPF-14 AND PROPOSED AMENDMENT NO. 251 TO LICENSE NPF-22:

"APPLICATION FOR LICENSE AMENDMENT AND RELATED TECHNICAL SPECIFICATION CHANGES TO IMPLEMENT FULL-SCOPE ALTERNATIVE SOURCE TERM IN ACCORDANCE WITH 10 CFR 50.67 - FOLLOWUP TO REQUEST FOR ADDITIONAL INFORMATION (RAI)" Docket Nos. 50-387 PLA-6119 and 50-388

Reference:

1) PLA-6114, Mr. B. T. McKinney (PPL)to Document Control Desk (USNRC)

ProposedAmendment No. 281 to License NPF-14and ProposedAmendment No. 251 to License NPF-22: "Applicationfor License Amendment and Related Technical Specification Changes to inplement Full-Scope Alternative Source Term in Accordance with 10 CFR 50.67-Response to Requestfor AdditionalInformnation,"

dated September 15, 2006.

The purpose of this letter is to transmit the attached figure, inadvertently omitted from Reference 1, which provided PPL's response to the NRC RAI Question #7. This marked up floor plan drawing shows the two office spaces on elevation 729' that are adjacent to the main control room and two areas on elevation 741' that are adjacent to the Technical Support Center (TSC), identified as an area of concern in the RAI.

Please contact Mr. Michael H. Crowthers at (610) 774-7766 should you require any additional information.

Respectfully, Britt T. McKinney

,+Ooc

Document Control Desk PLA-6119 Attachment - Markup of Drawing E105023 Sht. 1 cc: NRC Region I Mr. A. Blarney, NRC Sr. Resident Inspector Mr. R. V. Guzman, NRC Project Manager Mr. R. Janati, DEP/BRP

I Attachment to PLA-6119 Markup of Drawing E105023 Sheet I