Response to NRC Generic Letter 2016-01: Monitoring of Neutron-Absorbing Materials in Spent Fuel Pools
ML16321A405
Person / Time
Site: South Texas  STP Nuclear Operating Company icon.png
Issue date: 11/02/2016
From: Connolly J
South Texas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
GL-16-001, NOC-AE-16003414
Download: ML16321A405 (2)


Text

.......

Nuclear Operating Company 111111". -

South Texas Project Electric Generating Station P.O. BOK 28fl Wadsworth, Texas 77483 November 2, 2016 NOC-AE-16003414 10 CFR 50.54(f)

U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001 South T exa,s Project Units 1 and 2 Docket Nos. STN 50-498, STN 50-499 Category 1 Response to NRG Generic Letter 2016-01:

Monitoring of Neutron-Absorbing Materials in Spent Fuel Pools

Reference:

NRG Generic Letter 2016-01: Monitoring of Neutron-Absorbing Materials in Spent Fuel Pools, April 7, 2016(ML1697A169)

On April 7, 2016, the NRG issued the above reference to all power reactor licensees except those that have permanently ceased operation with all power reactor fuel removed from onsite spent fuel pool storage. The purpose of this letter is to provide a response for South Texas Project Electric Generating Station (STPEGS), Units 1 and 2. STPEGS Units 1 and 2 fit the requirements of the Category 1 response category. As a Category 1 licensee, this letter confirms that no neutron absorbing materials are currently credited to meet NRG requirements in 10 CFR 50.68, "Criticality Accident Requirements".

There are no commitments in this letter.

If there are any questions regarding this letter, please contact Wendy Brost at (361) 972-8516 or me at (361) 972-7344.

I decla~e under penalty of perjury that the foregoing is true and correct.

Executed on ~ .:<. 1 ;LO/~

Date.

James Connolly Site Vice President web STI: 34370453

NOC-AE-16003414 Page 2 of 2 cc:

(Paper Copy) (Electronic Copy)

Regional Administrator, Region IV Morgan. Lewis & Beckius LLP U.S. Nuclear Regulatory Commission Steve Frantz, Esquire 1600 East Lamar Boulevard Arlington, TX 76011-4511 U.S. Nuclear Regulatory Commission Lisa M. Regner Lisa M. Regner Senior Project Manager NRG South Texas LP U.S. Nuclear Regulatory Commission Chris O'Hara One White Flint North (08H04) Jim von Suski!

11555 Rockville Pike Skip Zahn Rockville, MD 20852 CPS Energy NRC Resident Inspector Kevin Pollo U. S. Nuclear Regulatory Commission Cris Eugster P. 0. Box 289, Mail Code: MN116 L. D. Blaylock Wadsworth, TX 77 483 City of Austin Elaina Ball John Wester Texas Dept. of State Health Services Helen Watkins Robert Free

Text

.......

Nuclear Operating Company 111111". -

South Texas Project Electric Generating Station P.O. BOK 28fl Wadsworth, Texas 77483 November 2, 2016 NOC-AE-16003414 10 CFR 50.54(f)

U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555-0001 South T exa,s Project Units 1 and 2 Docket Nos. STN 50-498, STN 50-499 Category 1 Response to NRG Generic Letter 2016-01:

Monitoring of Neutron-Absorbing Materials in Spent Fuel Pools

Reference:

NRG Generic Letter 2016-01: Monitoring of Neutron-Absorbing Materials in Spent Fuel Pools, April 7, 2016(ML1697A169)

On April 7, 2016, the NRG issued the above reference to all power reactor licensees except those that have permanently ceased operation with all power reactor fuel removed from onsite spent fuel pool storage. The purpose of this letter is to provide a response for South Texas Project Electric Generating Station (STPEGS), Units 1 and 2. STPEGS Units 1 and 2 fit the requirements of the Category 1 response category. As a Category 1 licensee, this letter confirms that no neutron absorbing materials are currently credited to meet NRG requirements in 10 CFR 50.68, "Criticality Accident Requirements".

There are no commitments in this letter.

If there are any questions regarding this letter, please contact Wendy Brost at (361) 972-8516 or me at (361) 972-7344.

I decla~e under penalty of perjury that the foregoing is true and correct.

Executed on ~ .:<. 1 ;LO/~

Date.

James Connolly Site Vice President web STI: 34370453

NOC-AE-16003414 Page 2 of 2 cc:

(Paper Copy) (Electronic Copy)

Regional Administrator, Region IV Morgan. Lewis & Beckius LLP U.S. Nuclear Regulatory Commission Steve Frantz, Esquire 1600 East Lamar Boulevard Arlington, TX 76011-4511 U.S. Nuclear Regulatory Commission Lisa M. Regner Lisa M. Regner Senior Project Manager NRG South Texas LP U.S. Nuclear Regulatory Commission Chris O'Hara One White Flint North (08H04) Jim von Suski!

11555 Rockville Pike Skip Zahn Rockville, MD 20852 CPS Energy NRC Resident Inspector Kevin Pollo U. S. Nuclear Regulatory Commission Cris Eugster P. 0. Box 289, Mail Code: MN116 L. D. Blaylock Wadsworth, TX 77 483 City of Austin Elaina Ball John Wester Texas Dept. of State Health Services Helen Watkins Robert Free