1CAN041301

April 10, 2013

U.S. Nuclear Regulatory Commission

Attn: Document Control Desk

Washington, DC 20555

Subject:

Response to Request for Additional Information Related to 10 CFR 50.46 30-Day Report

Arkansas Nuclear One - Unit 1

Docket No. 50-313

License No. DPR-51

References:

1. Entergy letter dated March 20, 2012, "10 CFR 50.46 Report -

Significant Change in Peak Cladding Temperature" (1CAN031202)

(ML12080A120)

2. NRC email dated November 8, 2012, "RAI on the Review of 10 CFR 50.46 30-day Report" (ML12313A440)
3. AREVA letter dated December 6, 2012, "Generic RAI Response to a 30-Day 10 CFR 50.46 Report of Significant PCT Change,"

(AREVA Letter NRC:12:062) (ML12342A381)

4. Entergy letter dated December 17, 2012, "Response to Request for Additional Information Related to 10 CFR 50.46 30 Day Report"

(1CAN121203) (ML12353A489)

5. NRC email dated March 21, 2013, "Request for Additional Information - TAC No. ME9719" (ML13080A350)
6. AREVA letter dated March 28, 2013, "Generic RAI Response to a 30-Day 10 CFR 50.46 Report of Significant PCT Change,"

(AREVA Letter NRC:13:014)

Dear Sir or Madam:

Entergy Operations, Inc. (Entergy) submitted a 30-day report to inform the NRC of two errors in the Arkansas Nuclear One, Unit 1 (ANO

-1) Emergency Core Cooling System evaluation model (Reference 1). The errors resulted in no net changes to the Peak Clad Temperature

calculated for the Large Break Loss-of-Coolant Accident. Each individual error as well as the

sum of the absolute values of the two errors is greater than the requirement of

10 CFR 50.46. Entergy Operations, Inc.

1448 S.R. 333 Russellville, AR 72802

Tel 479-858-4704 Stephenie L. Pyle Manager, Licensing A rkansas Nuclear One 1CAN041301 Page 2 of 2

On reviewing the submittal, the NRC staff requested additional information (RAI) to continue

the review and issued Reference 2. References 3 and 4 provided the responses to the

request.

Reference 5 provided the NRC's subsequent RAI. In response to this RAI, AREVA has

prepared a generic response to address these questions. This response is provided by

Reference 6.

This submittal contains no regulatory commitments.

Should you have any questions, please contact me.

Sincerely, Original signed by Stephenie L. Pyle SLP/rwc

cc: Mr. Arthur T. Howell Regional Administrator U. S. Nuclear Regulatory Commission Region IV 1600 East Lamar Boulevard Arlington, TX 76011-4511

NRC Senior Resident Inspector Arkansas Nuclear One P. O. Box 310

London, AR 72847 U. S. Nuclear Regulatory Commission

Attn: Mr. Kaly Kalyanam

MS O-8 B1

One White Flint North

11555 Rockville Pike

Rockville, MD 20852