Text

Nuclear Operating Company South Texas Pro/ect Electric Generating Station P. Bo 289 Wadsworth.

Texas 77483 October 20, 2011 NOC-AE-1 1002738 1 OCFR73.22 STI: 32959429 U. S. Nuclear Regulatory Commission Attention:

Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738 South Texas Project Units 1 & 2 Docket Nos. STN 50-498 & 50-499 Request For Approval Of Secure Voice Communications CCORE Module By Cellcrypt Limited

Reference:

National Institute of Standards and Technology (NIST) Cryptographic Module Validation Program (CMVP)Pursuant to 1OCFR73.22(f)(3), STP Nuclear Operating Company hereby requests approval to utilize mobile telephone devices to transmit Safeguards information with the Cellcrypt Mobile application and the CCORE Cryptographic Module by Cellcrypt Limited. The module meets the requirements of Federal Information Processing Standard (FIPS) 140-2 approved by the Nuclear Regulatory Commission per the latest validation list of the above reference.

Enclosed is Validation certificate No. 1310 for subject module.There are no commitments in this letter.If you have any questions on this matter, please contact Marilyn Kistler at (361) 972-8385 or me at (361) 972-4534.G. 0. Hildebrandt Manager, Plant Protection

Enclosure:

Validation certificate No. 1310 cc: (paper copy)(electronic copy)Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 612 East Lamar Blvd, Suite 400 Arlington, Texas 76011-4125 Balwant K. Singal Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North (MS 8 B1)11555 Rockville Pike Rockville, MD 20852 Senior Resident Inspector U. S. Nuclear Regulatory Commission P. O. Box 289, Mail Code: MNl 16 Wadsworth, TX 77483 C. M. Canady City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704 U. S. Nuclear Regulatory Commission Attention:

Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738 A. H. Gutterman, Esquire Morgan, Lewis & Bockius LLP Balwant K. Singal U. S. Nuclear Regulatory Commission John Ragan Chris O'Hara Jim von Suskil NRG South Texas LP Kevin Polio Richard Pena City Public Service Peter Nemeth Crain Caton & James, P.C.C. Mele City of Austin Richard A. Ratliff Texas Department of State Health Services Alice Rogers Texas Department of State Health Services FIPS 140-2 Validation Certificate A moi Tubeob"of*

O gitkis GIAmuift 11.1 usmiO Certificate No. 1310 The National Institute of Standards and Technology, as the United States FIPS 140-2 Cryptographic Module Validation Authority; and the Communications Security Establishment, as the Canadian FIPS 140-2 Cryptographic Module Validation Authority; hereby validate the FIPS 140-2 testing results of the Cryptographic Module identified as: CCORE Module by Cellcrypt Limited in accordance with the Derived Test Requirements for FIPS 140-2, Security Requirements for Cryptographic Modules.FIPS 140-2 specifies the security requirements that are to be satisfied by a cryptographic module utilized within a security system protecting Swmsvv Inkiemion (United States) or Protected Information (Canada) within computer and telecommunications systems (ncluding voice systems).Products which use the above kdentified cryptographic module may be labeled as complying with the requirements of FIPS 140-2 so long as the product, toughout its life cycle, contiue to use the validated version of the crytographic module as specified in this cerUficate.

The valdation report contains additional details concering test results. No relability test has been performed and no warranty of the products by both agencies is either expressed or implied.This certificate includes details on the scope of conformance and validation authority signatures on the reverse.Itt ACI -NST. dsin ~ U U.S~. w COsvmmse FIPS 140-2 provides four increasing, qualitative levels of security:

Level 1, Level 2, Level 3, and Level 4. These levels are intended to cover the wide range and potential applications and environments in which cryptographic modules may be employed.

The security requirements cover eleven areas related to the secure design and implementation of a cryptographic module. The scope of conformance achieved by the cryptographic modules as tested in the product identified as: CCORE Module by Cellcrypt Limited (Software Version: 0.6.0-rc3; Software)CEAL: a CygnaComn Solutions Laboratory, NVLAP Lab Code 200002-0 CRYPTIK Version 7.0 and tested by the Cryptographic Module Testing accredited laboratory:

is as follow: Cryptographic Module Specification:

Roles, Services, and Authentication:

Physical Security: (Mufti-Chip Standalone)

EMIWAC: Design Assurance:

Operational Environment:

Level 1 Level 1 Level NIA Cryptographic Module Ports and Interfaces:

Finite State Model: Cryptographic Key Management:

Level 1 Level 1 Level 1 Level 1 Level 1 Level 1 Self-Tests:

Mitigation of Other Attacks: tested in the following configuration(s):

Ubuntu Server Level 1 Level N/A The following FIPS approved Cryptographic Algorithms are used: AES (Cert. #1089); RSA (Cert. #514); SHS (Cert. #1022); HMAC (Cert. #612);RNG (Cert. #611)The cryptographic module also contains the following non-FIPS approved algorithms:

RSA (key wrapping; key establishment methodology provides 112 bits of encryption strength);

RC4; MD5;EC Diffie-Hellman (non-compliant);

ECDSA (non-compliant)

Overall Level Achieved:

1 Signed on behalf of the Government of the United States Signature: ( i),,L t.-...Signed on behalf of the Government of Canada Signature:

Dated:ý mcml- i a- I ?-D 1-0 Dated: M'&-" 110 P -1 Chief, Computer Scurity Division National Institute of Standards and Technology Director, Industry Program Group Communications Security Establishment Canada