The following was received from the Commonwealth of
Pennsylvania via fax:
On March 19, 2019, the licensee informed the Department [PA Department, Bureau of Radiation Protection] of a fixed gauge becoming disabled during routine source movement. It is reportable per 10 CFR 30.50(b)(2). Event location is Koppel, PA.
During the process of installing a Co-60 source rod and moving it from a transfer shield to a gauge and industrial process mold, the licensee observed difficulty in getting the source rod to insert into the mold. It is suspected that the rod is slightly bent. The rod was retracted into the fully shielded position in a spare transfer shield. The transfer shield containing the Co-60 rod was then taken to a designated storage area where it is secured from unauthorized access. A service provider has been contacted for possible repair or replacement. No exposures over regulatory limits occurred.
Radionuclide: Co-60
Manufacturer: Berthold Technologies
Source Model: P 2608-100
Gauge Model: LB 300 ML
Source Serial Number: unknown at this time
Activity: approximately 12 milliCuries
The rod has been securely stored and placed out of service until repairs or return can be accomplished by a licensed service provider. The Department has scheduled a reactive inspection. More information will be provided when available.
PA Event Report ID No: PA190009"