Submits Supplementary Info Supporting 880804 Tech Spec Change Request Re Secondary Safety Valves.Confirms That, Following Testing,Valves Will Be Adjusted to Plus or Minus 1% Tolerance
ML18053A646
Person / Time
Site: Palisades 
Issue date: 10/04/1988
From: KUEMIN J L
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NUDOCS 8810110224
Download: ML18053A646 (1)


Text

( consumers Power POWERINli MICHlliAN'S PROliRESS General Offices: 1945 West Parnall Road, Jackson, Ml 49201 * (517) 788-0550 October 4, 1988 Nuclear Regulatory Connnission Document Control Desk Washington, DC 20555 DOCKET 50-255 -LICENSE DPR-20 -PALISADES PLANT -SUPPLEMENTARY INFORMATION SUPPORTING TECHNICAL SPECIFICATIONS CHANGE REQUEST -SECONDARY SAFETY VALVES Consumers Power Company's Technical Specifications Change Request, of August 4, 1988, contained a typographical error in the discussion pertaining to supplemental sampling of the secondary safety valves. In accordance with ASME B&PV Code,Section XI, IWV 3513, 1983 edition, the correct formula should be: [(N + 12)/60]Z.

We also confirm that, although an as found +/- 3% tolerance is being adopted for the safety valve setpoint, following testing the valves will be adjusted to within +/- 1% tolerance.

Another typographical error is in change "B". "XJ" should be Roman numeral "XI".

Kuemin

  • S icensing Engineer CC Administrator, Region III, NRC NRC Resident Inspector

-Palisades

88101102:24