Text
(
consumers Power POWERINli MICHlliAN'S PROliRESS General Offices: 1945 West Parnall Road, Jackson, Ml 49201 * (517) 788-0550 October 4, 1988 Nuclear Regulatory Connnission Document Control Desk Washington, DC 20555 DOCKET 50-255 - LICENSE DPR PALISADES PLANT -
SUPPLEMENTARY INFORMATION SUPPORTING TECHNICAL SPECIFICATIONS CHANGE REQUEST -
SECONDARY SAFETY VALVES Consumers Power Company's Technical Specifications Change Request, of August 4, 1988, contained a typographical error in the discussion pertaining to supplemental sampling of the secondary safety valves.
In accordance with ASME B&PV Code,Section XI, IWV 3513, 1983 edition, the correct formula should be: [(N + 12)/60]Z.
We also confirm that, although an as found +/- 3% tolerance is being adopted for the safety valve setpoint, following testing the valves will be adjusted to within +/- 1% tolerance.
Another typographical error is in change "B".
"XJ" should be Roman numeral "XI".
/.~a.-~~
Kuemin S
icensing Engineer CC Administrator, Region III, NRC NRC Resident Inspector - Palisades
- 88101102:24 :381004'
- PDR ADOCK 05000255 P
_, _t=:PC\\
OC0988-0158-NL04