ML18067A221

From kanterella
Revision as of 17:16, 13 September 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Enclosure 1:Proposed Changes to FSAR Section 2.1.2 [03/08/2018 E-Mail from Y. Chen to N. Royston Question on Irradiated Dummy Rods Analysis]
ML18067A221
Person / Time
Site: Holtec
Issue date: 03/08/2018
From: Chen Y J
Spent Fuel Licensing Branch
To: Ngwayah R
HolTech
Chen Y J
Shared Package
ML18067A220 List:
References
Download: ML18067A221 (1)


Text

2.1.2 Intact SNF Specifications Intact fuel assemblies are defined as fuel assemblies without known or su spected cladding defects greater than pinhole leaks and hairline cracks, and which can be handled by normal means. The design payload for the HI-STORM 100 System is intact ZR or stainless steel (SS) clad fuel assemblies with the characteristics listed in Tables 2.1.17 through 2.1.24.

Intact fuel assemblies without fuel rods in fuel rod locations cannot be loaded into the HI-STORM 100 unless dummy fuel rods, which occupy a volume greater than or equal to the original fuel rods, replace the missing rods prior to loading. Any intact fuel assembly that falls within the geometric, thermal, and nuclear limits established for the design basis intact fuel assembly, as defined in Section 2.1.9 can be safely stored in the HI-STORM 100 System. If irradiated dummy rods are present in the fuel assembly, the site specific dose and dose rate analyses performed under 10CFR72.212 should include c onsiderations for the pr esence of such rods.