ML18156A171

From kanterella
Revision as of 14:33, 12 September 2018 by StriderTol (talk | contribs) (Created page by program invented by StriderTol)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
2018/06/05 Nuscale SMR TR RAIs - Request for Additional Information Letter No. 9158 (Erai No. 9158) Topical Report, Non-LOCA Analysis Methodology, 15.00.02, Srsb
ML18156A171
Person / Time
Site: PROJ0769
Issue date: 06/05/2018
From:
NRC
To:
NRC/NRO/DNRL/LB1
References
Download: ML18156A171 (7)


Text

"When the identification has been completed, the ranking process begins. The reason to numerically rank the processes and phenomena is based on the need to provide a systematic and consistent approach to all subsequent EMDAP activities."

oooo "A key feature of the adequacy assessment is the ability of the EM or its component devices to predict appropriate experimental behavior. Once again, the focus should be on the ability to predict key phenomena, as described in the first principle."

statement in TR Section 5.3.3.11 that "integral response is insensitive to the CPV temperature response"

d. Explain the basis for the statement that "integral response is insensitive to the CPV temperature response." In addition, p

3638, "Assessment of NRELAP5 Using SIET Fluid 2) Data," the purpose of which is to assess the NRELAP5 modeling of heat