SMR TR RAIs - Request for Additional Information Letter No. 9648 (Erai No. 9648) Topical Report, Thermal Hydraulics 15.06.05, SrsbML19014A091 |
Person / Time |
---|
Site: |
PROJ0769 |
---|
Issue date: |
01/14/2019 |
---|
From: |
NRC |
---|
To: |
NRC/NRO/DLSE/LB1 |
---|
References |
---|
Download: ML19014A091 (4) |
|
|
---|
Category:E-Mail
MONTHYEARML21361A2402022-01-0404 January 2022 Email Transmitting NRC Form 869 ML21361A1682021-12-29029 December 2021 Email Transmiting NRC 896 ML21361A1842021-12-27027 December 2021 Email Transmitting NRC Form 896 ML21116A1102021-04-26026 April 2021 SMR TR RAIs - FW: Request for Additional Information No.9828 (Erai No. 9828) ML21116A1572021-04-26026 April 2021 SMR TR RAIs - Request for Additional Information No. 9830 (Erai No. 9830) ML21117A3762021-04-22022 April 2021 SMR TR RAIs - Request for Additional Information No.9828 (Erai No. 9828) ML19178A4052019-06-27027 June 2019 SMR TR RAIs - Request for Additional Information Letter No. 9690 (Erai No. 9690) Topical Report, Design-Specific Methodology for Determining Appropriate Accidents to Be Evaluated Topical Report, 1.05, Rgrb ML19107A4982019-04-17017 April 2019 SMR TR RAIs - Request for Additional Information Letter No. 9676 (Erai No. 9676) Topical Report, Seismic System Analysis (SEB) ML19087A2862019-03-28028 March 2019 SMR TR RAIs - Request for Additional Information Letter No. 9666 (Erai No. 9666) Topical Report, Design-Specific Methodology for Determining Appropriate Accidents to Be Evaluated 1.05, SPRA ML19014A0912019-01-14014 January 2019 SMR TR RAIs - Request for Additional Information Letter No. 9648 (Erai No. 9648) Topical Report, Thermal Hydraulics 15.06.05, Srsb ML19011A0062019-01-11011 January 2019 SMR TR RAIs - Request for Additional Information Letter No. 9646 (Erai No. 9646) Topical Report, Thermal Hydraulics 1.05, SPRA ML18304A2372018-10-31031 October 2018 SMR TR RAIs - Request for Additional Information Letter No. 9580 (Erai No. 9580) Topical Report, Thermal Hydraulics 15.09, Srsb ML18295A6602018-10-22022 October 2018 SMR TR RAIs - Request for Additional Information Letter No. 9624 (Erai No. 9624) Topical Report Thermal Hydraulic Stability 15.9, Srsb ML18292A5812018-10-19019 October 2018 SMR TR RAIs - Request for Additional Information Letter No. 9578 (Erai No. 9578) Topical Report Thermal Hydraulic Stability 15.9, Srsb ML18292A5822018-10-19019 October 2018 SMR TR RAIs - Request for Additional Information Letter No. 9579 (Erai No. 9579) Topical Report Thermal Hydraulic Stability 15.9, Srsb ML18226A3282018-08-14014 August 2018 SMR TR RAIs - Request for Additional Information Letter No. 9575 (Erai No. 9575) Topical Report Thermal Hydraulic Stability 15.9, Srsb ML18226A3292018-08-14014 August 2018 SMR TR RAIs - Request for Additional Information Letter No. 9576 (Erai No. 9576) Topical Report Thermal Hydraulic Stability 15.9, Srsb ML18199A1932018-07-18018 July 2018 SMR TR RAIs - Request for Additional Information Letter No. 9492 (Erai No. 9492) Topical Report LOCA 15.6.5, Srsb ML18171A3292018-06-20020 June 2018 SMR TR RAIs - Request for Additional Information Letter No. 9351 (Erai No. 9351) Transient Analysis, 15, Srsb ML18171A3272018-06-20020 June 2018 SMR TR RAIs - Request for Additional Information Letter No. 9158 (Erai No. 9158) Topical Report, Transient and Accident Analysis, 15.00.02, Srsb ML18169A4212018-06-18018 June 2018 SMR TR RAIs - Request for Additional Information Letter No. 9444 (Erai No. 9444) Topical Report Thermal Hydraulic, 15.9, Srsb R1 ML18156A1772018-06-0505 June 2018 SMR TR RAIs - Request for Additional Information Letter No. 9351 (Erai No. 9351) Transient Analysis Methodology, 15, Srsb ML18156A1712018-06-0505 June 2018 SMR TR RAIs - Request for Additional Information Letter No. 9158 (Erai No. 9158) Topical Report, Non-LOCA Analysis Methodology, 15.00.02, Srsb ML18148A0032018-05-28028 May 2018 SMR TR RAIs - Request for Additional Information Letter No. 9475 (Erai No. 9475) Topical Report, LOCA, 15.6.5, Srsb ML18148A0022018-05-28028 May 2018 SMR TR RAIs - Request for Additional Information Letter No. 8930 (Erai No. 8930) Topical Report, Transient and Accident Analysis, 15, Srsb ML18129A4072018-05-0909 May 2018 SMR TR RAIs - Request for Additional Information Letter No. 9374 (Erai No. 9374) Topical Report, Non-LOCA Analysis Methodology, 15.00.02, Srsb ML18128A3432018-05-0808 May 2018 SMR TR RAIs - Request for Additional Information Letter No. 9085 (Erai No. 9085) Topical Report, LOCA, 15.06.05, Srsb ML18128A3892018-05-0808 May 2018 SMR TR RAIs - Request for Additional Information Letter No. 9513 (Erai No. 9513) Topical Report, Non-LOCA Analysis Methodology, 15.00.02, Srsb ML18128A3882018-05-0808 May 2018 SMR TR RAIs - Request for Additional Information Letter No. 9476 (Erai No. 9476) Topical Report, LOCA, 15.06.05, Srsb ML18128A3412018-05-0808 May 2018 SMR TR RAIs - Request for Additional Information Letter No. 9466 (Erai No. 9466) Topical Report, Non-LOCA Analysis Methodology, 15.00.02, Srsb ML18094A9802018-04-0404 April 2018 SMR TR RAIs - Request for Additional Information Letter No. 9306 (Erai No. 9306) Topical Report, Rod Ejection Accident Methodology, 15.04.08, Srsb ML18094A9662018-04-0303 April 2018 SMR TR RAIs - Request for Additional Information Letter No. 9441 (Erai No. 9441) Topical Report, Thermal Hydraulic Stability, 15.09, Srsb ML18090A0112018-03-31031 March 2018 SMR TR RAIs - Request for Additional Information Letter No. 9438 (Erai No. 9438) Topical Report, Thermal Hydraulic Stability, 15.09, Srsb ML18090A0122018-03-31031 March 2018 SMR TR RAIs - Request for Additional Information Letter No. 9439 (Erai No. 9439) Topical Report, Thermal Hydraulic Stability, 15.09, Srsb ML18086B7892018-03-27027 March 2018 SMR TR RAIs - Request for Additional Information Letter No. 9417 (Erai No. 9417) Topical Report, Thermal Hydraulic Stability, 15.09, Srsb ML18079A4592018-03-20020 March 2018 SMR TR RAIs - Request for Additional Information Letter No. 9443 (Erai No. 9443) Topical Report, Thermal Hydraulic Stability, 15.09, Srsb ML18078B3162018-03-19019 March 2018 SMR TR RAIs - Request for Additional Information Letter No. 9440 (Erai No. 9440) Topical Report Thermal Hydraulic Stability, 15.09, Srsb ML18054A2802018-02-23023 February 2018 SMR TR RAIs - Request for Additional Information Letter No. 9388 (Erai No. 9388) Topical Report TR-0516-49417-P (Stability Analysis) ML18039A0122018-02-0808 February 2018 SMR TR RAIs - Request for Additional Information Letter No. 9173 (Erai No. 9173) Topical Report Thermal Hydraulic ML18038B0602018-02-0707 February 2018 SMR TR RAIs - Request for Additional Information Letter No. 9173 (Erai No. 9173) Topical Report Thermal Hydraulic ML18038B4712018-02-0707 February 2018 SMR TR RAIs - Request for Additional Information Letter No. 9173 (Erai No. 9173) Topical Report Thermal Hydraulic ML18033B7432018-02-0202 February 2018 SMR TR RAIs - Request for Additional Information Letter No. 9333 (Erai No. 9333) Topical Report Thermal Hydraulic ML18028A0112018-01-28028 January 2018 SMR TR RAIs - Request for Additional Information Letter No. 9190 (Erai No. 9190) Topical Report LOCA ML17252A6882017-09-0909 September 2017 SMR TR RAIs - Request for Additional Information Letter No. 9086 (Erai No. 9086) Topical Report Thermal Hydraulic Design 2022-01-04
[Table view] |
Text
NuScaleTRRaisPEm Resource From: Cranston, Gregory Sent: Monday, January 14, 2019 10:27 AM To: NuScaleTRRaisPEm Resource Cc: Lee, Samuel; Karas, Rebecca; Thurston, Carl; Franovich, Rani; Bavol, Bruce; Chowdhury, Prosanta
Subject:
Request for Additional Information Letter No. 9648 (eRAI No. 9648) Topical Report, Thermal Hydraulics , 15.06.05, SRSB Attachments: Request for Additional Information No. 9648 (eRAI No.9648).pdf Attached please find NRC staffs request for additional information (RAI) concerning review of the NuScale Topical Report.
Please submit your technically correct and complete response by March 8, 2019, to the NRC Document Control Desk.
If you have any questions, please contact me.
Thank you.
1
Hearing Identifier: NuScale_SMR_DC_TR_Public Email Number: 107 Mail Envelope Properties (BN8PR09MB36038E443BDE1D6A70F313F890800)
Subject:
Request for Additional Information Letter No. 9648 (eRAI No. 9648) Topical Report, Thermal Hydraulics , 15.06.05, SRSB Sent Date: 1/14/2019 10:27:20 AM Received Date: 1/14/2019 10:27:25 AM From: Cranston, Gregory Created By: Gregory.Cranston@nrc.gov Recipients:
"Lee, Samuel" <Samuel.Lee@nrc.gov>
Tracking Status: None "Karas, Rebecca" <Rebecca.Karas@nrc.gov>
Tracking Status: None "Thurston, Carl" <Carl.Thurston@nrc.gov>
Tracking Status: None "Franovich, Rani" <Rani.Franovich@nrc.gov>
Tracking Status: None "Bavol, Bruce" <Bruce.Bavol@nrc.gov>
Tracking Status: None "Chowdhury, Prosanta" <Prosanta.Chowdhury@nrc.gov>
Tracking Status: None "NuScaleTRRaisPEm Resource" <NuScaleTRRaisPEm.Resource@nrc.gov>
Tracking Status: None Post Office: BN8PR09MB3603.namprd09.prod.outlook.com Files Size Date & Time MESSAGE 329 1/14/2019 10:27:25 AM Request for Additional Information No. 9648 (eRAI No.9648).pdf 73253 Options Priority: Standard Return Notification: No Reply Requested: No Sensitivity: Normal Expiration Date:
Recipients Received:
Request for Additional Information No. 9648 (eRAI No.9648)
Issue Date: 01/14/2019 Application
Title:
NuScale Topical Report Operating Company: NuScale Docket No. PROJ0769 Review Section: 15.06.05 - Loss of Coolant Accidents Resulting From Spectrum of Postulated Piping Breaks Within the Reactor Coolant Pressure Boundary Application Section: 15.06.05 QUESTIONS 15.06.05-22 Title 10 of the COde of Federal Regulations (CFR) Part 50, Appendix K, II (Required Documentation) requires,
- 1. a. A description of each evaluation model shall be furnished. The description shall be sufficiently complete to permit technical review of the analytical approach including the equations used, their approximations in difference form, the assumptions made, and the values of all parameters or the procedure for their selection, as for example, in accordance with a specified physical law or empirical correlation.
- 1. b. A complete listing of each computer program, in the same form as used in the evaluation model, must be furnished to the Nuclear Regulatory Commission upon request.
By letter dated March 7, 2017 (ML17066A463), NuScale submitted supplemental information in support of multiple NuScale topical reports (TR), including the loss of coolant analysis (LOCA) methodology TR. Among the files submitted were those related to the NRELAP5 code executable, at the request of the staff in a public meeting held on March 2, 2017 (ML17061A569) in support of 10 CFR 50, Appendix K documentation requirements. The code executable was provided as an acceptable alternative to the requirement to furnish the source code, if requested.
The NRELAP5 version provided by NuScale was Version 1.3, which was the current version at the time. On July 17, 2018, NRC staff held a public meeting (ADAMS Accession # ML18141A735) with NuScale Power LLC and discussed various topics related to NuScales Topical Report, LOSS OF COOLANT ACCIDENT EVALUATION MODEL. During the meeting, NuScale informed NRC staff that a new version of NRELAP5 code has been developed and will be used to replace Version 1.3, which was the reference version submitted with the LOCA topical report submittal. In addition, NuScale indicated that all Final Safety Analysis Report (FSAR) Chapter 15 event analyses will be reanalyzed using Version 1.4.
After the public meeting, NRC staff audited the code development files related to the development of NRELAP5 Version 1.4 and found several code updates including the following major model updates:
- 1. Updated critical heat flux (CHF) model for the Extended Hench Levy and Chang implementation and modified-Zuber implementation;
- 2. Updated Windows executable to 64-bit version;
- 3. Real*16 precision is now default to replace Real*8 precision;
- 4. Correction to Moody/Henry-Fauske Choking model;
- 5. Shah Correlation Condensation model fixes and update.
The NRC staff must make a regulatory finding on whether the NRELAP5 code performs adequately to predict relevant figures of merit (FoM) in the licensing basis analysis, some of which have limited margin. To assess NRELAP5s ability to predict the important FoM, the staff must evaluate the evaluation model (EM). Evaluation of the EM involves review of user selectable options or inputs considered part of the EM. The selection of user options or inputs can affect the correlations used and/or the stability of the numerical results (i.e., numerical stability solution), and user selected modeling criteria can have potentially non-conservative impacts that might not be readily apparent when looking only at the FoM. To assess the EM, with what the staff considers a significantly modified version (from Version 1.3 to Version 1.4), the staff is requesting the following information be submitted:
- 1. Version 1.4 of NRELAP5 source code listing, or, as an alternate, Version 1.4 of NRELAP5 code executable (with staff access to the source code via audit);
- 2. All the necessary model update descriptions in the relevant theory manual;
- 3. Basemodel Rev1 NuScale Power Module' input model decks for the limiting LOCA core coverage and containment pressure cases. Provide both steady-state and transient model decks:
- 4. Basemodel Rev3 NIST-1 input model deck for HP-49 (or HP-43). Provide both steady-state and transient model decks.