Enclosure 1 Certificate of Compliance No. 9371, Revision No. 3 [Letter to L. Podolak Renewal of Certificate of Compliance No. 9371 for the Model No. 360 Series]
ML18240A405
Person / Time
Site: 07109371
Issue date: 08/27/2018
From: McKirgan J B
Spent Fuel Licensing Branch
To: Podolak L
QSA Global
Garcia-Santos N G
Shared Package
ML18240A402 List:
References
EPID L-2018-RNW-0008
Download: ML18240A405 (4)


Text

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.a. CERTIFICATE NUMBERb.REVISION NUMBERc. DOCKET NUMBERd.PACKAGE IDENTIFICATION NUMBERPAGE PAGES 937 1 3 71-9371USA/9371/B(U)

-96 1 OF 4 2.PREAMBLE a.This certificate is issued to certify that the package (packaging and contents) described in Item 5 below meets the applicable safety standards setforth in Title 10, Code of Federal Regulations, Part 71, "Packaging and Transportation of Radioactive Material."

b.This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation orother applicable regulatory agencies, including the government of any country through or into which the package will be transported.

3.THIS CERTIFICATE IS ISSUED ON THE BASIS OF A SAFETY ANALYSIS REPORT OF THE PACKAGE DESIGN OR APPLICATION a.ISSUED TO (Name and Address) b.TITLE AND IDENTIFICATION OF REPORT OR APPLICATIONQSA Glob al , Inc.40 North AvenueBurlington, MA 01803QSA Global , Inc., application dated April 25, 2018

.4.CONDITIONSThis certificate is conditional upon fulfilling the requirements of 10 CFR Part 71, as applicable, and the conditions specified below.

5. (a)Packaging (1)Model No.:

360 (2)Description The Model No. 360 series of packages consist of a family of five package configurationsused to transport Ir

-192, Yb-169, and Se

-75 source assemblies that meet t he requirements for special form material. These five packages are the Model Nos. 360-2 , 360-4, 360-4W, 360-10, and 360

-10W. The external dimensions of all models ar e identical and are approximately: 15 inches

[38 centimeters (cm)] long, 13.5 inches (34 cm)wide, and 15.9 inches (40 cm) tall.

The major components of the package include: (i) the container assembly, (ii) the shield assembly, (iii) the shield retainer, (iv) the source securing assembly, (v) the cover assembly, and (vi) the source assemblies. Shielding is provided by either all tungsten or a combination of tungsten and depleted uranium shields. Models with the "W" designation use all tungsten shielding. An optional adapter tungsten shield can also be added to the top side of the Model No. 360 for additional shielding. Depending on the source assembly to be transported, the source capsule will be attached to either a flexible steel wire or will be incorporated into a segment of a source chain. Each source securing mechanism incorporates a locking mechanism to secure the source inside the package and a source dust cap to further protect the end of the source assembly during transport. A lock assembly will secure the various lengths of the source assembles in the Model Nos. 360

-2, 360-4, and 360

-4W. Those models have NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.a. CERTIFICATE NUMBERb.REVISION NUMBERc. DOCKET NUMBERd.PACKAGE IDENTIFICATION NUMBERPAGE PAGES 937 1 3 71-9371USA/9371/B(U)

-96 2 OF 4 5.(a)(2)Description (continued) the option of three loading positions: bottom, middle, or top. For the Model Nos. 360

-1 0 and 360-10W, chain assemblies, which are shorter in length, will be secured to thelocking assembly via stainless steel jumper extensions.

The maximum weight of the package varies depending on the configuration. T he maximum package weights are listed in the table below:

Model No. Package Weight 360-2110 lbs. (50 kg) 360-4130 lbs. (59 kg) 360-4W155 lbs. (70.3 kg) 360-10170 lbs. (77 kg) 360-10W180 lbs. (82 kg) (3)Drawings The package is constructed in accordance with QSA Global, Inc., Drawing No. R36000 ,Rev. G , sheets 1-10.The package user should reference QSA Global, Inc., Drawing No. R 360-User, Revision C , s heets 1-2.(b)Contents (1)Type and form of material Iridium-192 (Ir-192), Selenium-75 (Se-75), and Ytterbium-159 (Yb-159), as seal ed sources, which meet the requirements of special form radioactive material.

All source wire assemblies consist of the source capsule attached to either a flexibl e steel wire or incorporated into a segment of a source chain

.(2)Maximum quantity of material per package:The maximum quantity of Se

-75 and Yb-169 is 5,000 curies (Ci) for all variations of t he Model No. 360 transportation package. For Ir

-192, the values may depend on t he location of the package and are listed in Table 1 below.

NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.a. CERTIFICATE NUMBERb.REVISION NUMBERc. DOCKET NUMBERd.PACKAGE IDENTIFICATION NUMBERPAGE PAGES 937 1 3 71-9371USA/9371/B(U)

-96 3 OF 4 5.(b)(2)Maximum quantity of material per package (continued):Table 1 Output curies for Ir-192 are determined by measuring the source output at 1 meter and expressing its activity in curies derived from the following: 0.48 R/(hr-Ci) (Ref: American National Standards Institute N432

-1980, "Radiological Safety for the Design and Construction of Apparatus for Gamma Radiography"). (3)Maximum weight of contents:

0.3 lbs. (138 grams) for the Model No.

360-2 package. 0.6 lbs. (276 grams) for the Model Nos. 360

-4 and 360-4W packages. 1.5 lbs. (690 grams) for the Model Nos.

360-10 and 3 60-10W packages. The maximum content weight includes the mass of radioactive material and the source capsule handling wire assembly for a shipment containing the maximum number of source wire assemblies that can be transported in a package (i.e., 2 source assemblies for the Model No. 360-2 , 4 source assemblies for the Model No

s. 360-4 and 360-4W packages, and 10 source assemblies for the Model Nos.

360-10 and 3 60-10W packages). (4)Maximum decay heat:

21 watts 6.In addition to the requirements of Subpart G of 10 CFR Part 71:

(a)The package shall be prepared for shipment and operated in accordance with the Operatin g Procedures in Section No. 7 of the application; (b)The package must meet the Acceptance Tests and Maintenance Program of Section No. 8.0 ofthe application

.7.The package authorized by this certificate is hereby approved for use under the general licens e provisions of 10 CFR 71.17.Model No. Activity Shield Location Maximum Package Capacity Maximum Number of Sources 360-2Bottom 300 Ci 2 Top or Middle 270 Ci 360-4Bottom 600 Ci 4 Top of Middle 540 Ci 360-4WAny 260 Ci 4 360-10Any 1,500 Ci 10 369-10WAny 170 Ci 10 NRC FORM 618 (8-2000) 10 CFR 71 U.S. NUCLEAR REGULATORY COMMISSION CERTIFICATE OF COMPLIANCE FOR RADIOACTIVE MATERIAL PACKAGES 1.a. CERTIFICATE NUMBERb.REVISION NUMBERc. DOCKET NUMBERd.PACKAGE IDENTIFICATION NUMBERPAGE PAGES 937 1 3 71-9371USA/9371/B(U)

-96 4 OF 4 8.Revision No. 2 of this certificate may be used until August 31, 2020

.9.Expiration date: August 31 , 2023.REFERENCES Q SA Global, Inc., application dated April 25, 2018. FO R THE U.S. NUCL EAR REGULATORY C OMMISSION John McKirgan, Chief Spent Fuel Licensing Branch Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards Date: