Semantic search

Jump to navigation Jump to search
Condition
Printout selection
Options
Parameters [
limit:

The maximum number of results to return
offset:

The offset of the first result
link:

Show values as links
headers:

Display the headers/property names
mainlabel:

The label to give to the main page name
intro:

The text to display before the query results, if there are any
outro:

The text to display after the query results, if there are any
searchlabel:

Text for continuing the search
default:

The text to display if there are no query results
class:

An additional CSS class to set for the table
transpose:

Display table headers vertically and results horizontally
sep:

The separator between results
prefix:

Control display of namespace in printouts
Sort options
Delete
Add sorting condition
 Start dateReporting criterionTitleEvent descriptionSystemLER
ENS 539783 April 2019 04:00:00Agreement StateAgreement State Report - Fixed Gauge Missing ShutterThe following report was received via e-mail: On 4/3/19, during preparation to conduct maintenance on a coal chute, workers prepared to isolate a gauge from service to prevent worker exposure to the beam. It was discovered that the gauge was missing its isolation shutter. The RSO (Radiation Safety Officer) and plant personnel conducted an extensive search and investigation of the missing shutter, but it could not be located. A six-month physical inventory of the facilities devices was conducted on 3/26/19 and 3/27/19 and there was no notation of any problems with this gauge on the inventory sheets. The gauge involved is a Texas Nuclear Model 5189 with a 20 mCi Cesium-137 source. The RSO and job supervisor held a discussion and decided that they could use the shutter from another Model 5189 gauge in the vicinity. The second gauge is used in a continuously operating process line and would have the shutter open for operations. The area around the second gauge will have signage and barricades installed to safely mark the area if future work activities will take place in that location. The shutter from the second gauge was placed on the first gauge and it was tagged out for maintenance of the coal chute. The second gauge remains in the open position during operation of the second process line. The RSO contacted ThermoFisher Scientific and discovered that because of the age of the gauge, replacement parts could not be obtained. They were provided with a list of third-party service providers to assist with proper repair or removal and disposal of the gauge. The licensee will explore options and inform ODH (Ohio Department of Health) of the actions to be taken. Ohio Item Number: OH190005