Issue date | Title | Topic | |
---|---|---|---|
IR 05000029/1973006 | 29 March 1974 | Ack Receipt of Re Discrepancies Found in 740121 Insp Rept 50-029/73-06.Info Re Monitoring or Routing Machine Shop Exhaust Air Waste Gas Loop Seal & Gravity Drain Tank Vent Under Review.Further Questions Examined at Next Insp | Loop seal |
IR 05000029/1974008 | 7 August 1974 | Forwards Insp Rept 50-029/74-08 on 740716-18.No Noncompliance Noted | |
IR 05000029/1974014 | 14 November 1974 | Insp Rept 50-029/74-14 on 741022-25.Noncompliance Noted: Approved Procedures Not Followed,Chloride Concentration Limit Exceeded, & Active Jumper & Bypass Request Review Not Documented | |
IR 05000029/1975006 | 27 May 1975 | IE Insp Rept 50-029/75-06 on 750506-07.No Noncompliance Noted.Major Areas Inspected:Nuclear Safety Audit & Review Committee Performance for Period May 1974-Apr 1975 | |
IR 05000029/1975015 | 11 November 1975 | IE Insp Rept 50-029/75-15 on 751023-24.No Noncompliance Noted.Major Areas Inspected:Activities Re Measurement of Steam Generator Tube Wall Thickness Using Eddy Current Techniques | Hydrostatic |
IR 05000029/1981020 | 30 June 1982 | Forwards IE Emergency Preparedness Appraisal Rept 50-029/81-20 on 811201-09.Emergency Preparedness Findings & Improvement Items Encl | |
IR 05000029/1982004 | 19 July 1982 | Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in IE Insp Rept 50-029/82-04 | |
IR 05000029/1982007 | 28 May 1982 | IE Insp Rept 50-029/82-07 on 820504-07.Noncompliance Noted: Ineffective Corrective Action Associated W/Licensee Identified QA Audit Findings | |
IR 05000029/1985001 | 13 June 1985 | Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-029/85-01. Corrective Actions Adequately Address Insp Concerns & Will Be Examined During Future Insp | |
IR 05000029/1985005 | 2 May 1985 | Insp Rept 50-029/85-05 on 850304-08.No Violation Noted.Major Areas Inspected:Implementation & Status of NUREG-0737 Task Actions,Including post-accident Sampling of Reactor Coolant & Containment Atmosphere & Effluent Monitoring | Grab sample |
IR 05000029/1985007 | 4 June 1985 | Insp Rept 50-029/85-07 on 850321-0426.Violation Noted: Failure to Provide Adequate Procedure for Conducting Required Surveillance of Meteorological Equipment | Boric Acid Packing leak Grab sample Fuel cladding |
IR 05000029/1985008 | 11 June 1985 | Insp Rept 50-029/85-08 on 850513-16.No Violation Noted. Major Areas Inspected:Annual Emergency Exercise Performed on 850515 | |
IR 05000029/1985009 | 13 June 1985 | Insp Rept 50-029/85-09 on 850506-10.No Noncompliance Noted. Major Areas Inspected:Radiation Protection Program, Status of Previously Identified Items,Dosimetry,Control of Work & Routine Radiological Surveys | High Radiation Area |
IR 05000029/1985010 | 3 July 1985 | Insp Rept 50-029/85-10 on 850528-31.No Violations Noted. Major Areas Inspected:Operational Radiological Environ Monitoring Program,Including Mgt Controls,Program for QC of Analytical Measurements & Meteorological Monitoring | Offsite Dose Calculation Manual Annual Radiological Environmental Operating Report |
IR 05000029/1985011 | 3 July 1985 | Insp Rept 50-029/85-11 on 850506-0610.No Violation Noted. Major Areas Inspected:Previous Findings,Operational Safety Verification Reviews,Bimonthly Safety Sys Walkdown,Plant Events & Emergency Planning Drill | Safe Shutdown Boric Acid High Radiation Area Fuel cladding |
IR 05000029/1985012 | 16 July 1985 | Insp Rept 50-029/85-12 on 850603-07.No Violation Noted. Unresolved Items Noted:Failure to Provide Documentary Evidence of Preventive Maint Activities for safety-related Equipment | |
IR 05000029/1985013 | 5 July 1985 | Insp Rept 50-029/85-13 on 850603-07.No Violations Noted. Major Areas Inspected:Licensee Requirements for Const of Safe Shutdown Sys (SSS) Bldg & Observation of SSS Bldg Concrete Const Activities & Soil Backfill | Safe Shutdown Earthquake Troxler |
IR 05000029/1985014 | 30 August 1985 | Insp Rept 50-029/85-14 on 850611-0729.No Violations Noted. Major Areas Inspected:Operational Safety Verification Reviews,Bimonthly Safety Sys Walkdown,Review of Radiological Controls & Maint Observations | Boric Acid Grab sample Fire Barrier Fuel cladding Fire Watch |
IR 05000029/1985015 | 31 October 1985 | Insp Rept 50-029/85-15 on 850730-0919.No Violation Noted. Major Areas Inspected:Operational Safety Verification Reviews,Radiological Controls,Plant Events,Maint, Surveillance & Emergency Preparedness Activities | Boric Acid Loop seal Packing leak Fire Barrier Fire Watch Coast down Siren |
IR 05000029/1985016 | 25 September 1985 | Insp Rept 50-029/85-16 on 850812-16.No Noncompliance Noted. Major Areas Inspected:Radiation Protection Program,Including Respiratory Protection,Spent Resin Shipment,Alara & Radiation Protection Procedures Upgrade Project | Systematic Assessment of Licensee Performance |
IR 05000029/1985017 | 13 December 1985 | Physical Security Insp Rept 50-029/85-17 on 850909-12. Licensee in Compliance.Major Areas Inspected:Security Plan & Implementing Procedures,Mgt Effectiveness & Personnel Training.Portions Deleted (Ref 10CFR73.21 & 2.790) | Safeguards Contingency Plan |
IR 05000029/1985018 | 10 January 1986 | Insp Rept 50-029/85-18 on 850926-1125.No Violations Noted. Major Areas Inspected:Review of Licensee Action on Previous Findings,Radiological Controls & Maint Observations. Inadequacies Re Fire Barriers Noted | Boric Acid Fire Barrier Excess Flow Check Valve Fuel cladding Fire Protection Program Fire Watch Overexposure |
IR 05000029/1985019 | 13 November 1985 | Insp Rept 50-029/85-19 on 851007-08.No Violations Noted. Major Areas Inspected:Licensee Action to Address Proposed Changes to Tech Spec Re Main Coolant Sys Structural Integrity Surveillance Requirements | |
IR 05000029/1985020 | 14 November 1985 | Insp Rept 50-029/85-20 on 851021-25.No Violation Noted.Major Areas Inspected:Maint Program | Systematic Assessment of Licensee Performance |
IR 05000029/1985021 | 13 December 1985 | Insp Rept 50-029/85-21 on 851105-07.No Violation Noted. Major Areas Inspected:Nonradiological Chemistry Program, Including Training,Measurement Control & Analytical Procedure Evaluations | |
IR 05000029/1985022 | 31 January 1986 | Exam Rept 50-029/85-22 on 851029-31.Exam Results:All Candidates Failed Written Exam.One Reactor Operator Candidate Also Failed Oral Operational Exam | Boric Acid Power change |
IR 05000029/1985023 | 27 November 1985 | Insp Rept 50-029/85-23 on 851028-1101.No Noncompliance Noted.Major Areas Inspected:Radiation Protection Program, Including ALARA Implementation During Outage,Control of Work & Frisking | Overexposure |
IR 05000029/1985024 | 12 February 1986 | Insp Rept 50-029/85-24 on 851126-860106.No Violation Noted. Deficiency Noted:Setpoint for Main Coolant Sys Low Set Code Safety Valve Exceeded Tech Spec Requirement | Safe Shutdown Boric Acid |
IR 05000029/1985025 | 10 April 1986 | Ack Receipt of Informing NRC of Steps Taken to Correct Violations Noted in Insp Rept 50-029/85-25. Corrective & Preventive Actions Will Be Examined During Future Insp | |
IR 05000029/1985098 | 9 March 1987 | Forwards SALP Rept 50-029/85-98 for 850201-861006.Attendees List for 870106 Meeting W/Util Also Encl.Informs That Util Selected for Reduced Level Insp Effort by Region 1 Due to Continuing Superior Performance Record | Safe Shutdown Fire Barrier Systematic Assessment of Licensee Performance |
IR 05000029/1985099 | 31 May 1985 | Final SALP Rept 50-029/85-99 for Sept 1983 - Jan 1985 | Hydrostatic Coatings Process Control Program Systematic Assessment of Licensee Performance Exemption Request Fuel cladding Fire Watch Backfit |
IR 05000029/1986001 | 11 March 1986 | Insp Rept 50-029/86-01 on 860113-17.No Noncompliance or Deviation Noted.Major Areas Inspected:Cycle 17/18 Refueling/ Startup Test,Including Precritical Tests,Power Escalation Tests & Administrative Controls of Test Procedures | Shutdown Margin |
IR 05000029/1986002 | 24 March 1986 | Insp Rept 50-029/86-02 on 860107-0214.Violation Noted: Failure to Provide Adequate Procedure for Conducting Tech Spec Required Surveillance of Process Radiation Monitoring Sys | Safe Shutdown Boric Acid Fire Barrier Hydrostatic |
IR 05000029/1986003 | 23 April 1986 | Discusses 860307 Meeting in Region I Ofc Re Results of Recent Operator Licensing Exams & Findings of Insp Rept 50-029/86-03.Meeting Improved Understanding of Position on Util Appeal of Oct 1985 Licensing Exams | |
IR 05000029/1986004 | 3 April 1986 | Insp Rept 50-029/86-04 on 860225-28.No Violation or Deviation Noted.Major Areas Inspected:Licensee Radwaste Mgt Program,Including Mgt Controls,Radioactive Effluent Release Records & Effluent Control Instrumentation | Offsite Dose Calculation Manual Process Control Program |
IR 05000029/1986005 | 18 July 1986 | Insp Rept 50-029/86-05 on 860312-0609.No Violation Noted. Inadequacy Noted:Failure to Comply W/Tech Specs Re Nuclear Instrumentation Channels.Major Areas Inspected:Maint & Surveillance Observations | Safe Shutdown Boric Acid Hydrostatic Fire Watch Power change |
IR 05000029/1986006 | 11 July 1986 | Insp Rept 50-029/86-06 on 860610-12.No Violations Noted. Major Areas inspected:860611 Annual Emergency Exercise. Deficiencies Noted:Overall Command & Control Not Provided by Single Individual & Protective Measures Deficient | |
IR 05000029/1986007 | 14 August 1986 | Exam Rept 50-029/86-07OL on 860521-22.Exam Results:One Reactor Operator Candidate & Two Senior Reactor Candidates Licensed & One Reactor Operator Candidate Failed Oral Exam. Sys Training Manuals Incomplete & Inaccurate | |
IR 05000029/1986008 | 24 October 1986 | Insp Rept 50-029/86-08 on 860610-1006.Violation Noted: Failure to Maintain & Verify Closed Main Coolant Bypass Valve in at Least One Loop in Operation.Inadequacy Noted: Failure to Provide Timely Emergency Notification | Safe Shutdown Boric Acid Fitness for Duty Offsite Dose Calculation Manual Fire Barrier Process Control Program Fuel cladding Biofouling |
IR 05000029/1986009 | 3 July 1986 | Insp Rept 50-029/86-09 on 860626-0702.Violations Noted:Rcs Vents & Emergency Feedwater Sys Inoperable from 851202-03 Until 860626 & Maint Support Dept Resources & Training Insufficient | |
IR 05000029/1986010 | 14 August 1986 | Insp Rept 50-029/86-10 on 860721-22.No Violations Noted. Major Areas Inspected:Emergency Preparedness Program & Previously Identified Insp Findings | |
IR 05000029/1986011 | 5 September 1986 | Insp Rept 50-029/86-11 on 860811-15.No Violation Noted.Major Areas Inspected:Surveillance Testing & Calibr Control Program for Instrumentation & Control Depts | |
IR 05000029/1986012 | 8 September 1986 | Insp Rept 50-029/86-12 on 860811-15.No Noncompliance Noted. Major Areas Inspected:Radiation Protection Program,Including Organization & Staffing,Procedures Rev Project,Inpo Audit, Recordkeeping & QC Program for Radwaste | |
IR 05000029/1986014 | 7 November 1986 | Partially Withheld Physical Security Insp Rept 50-029/86-14 on 860825-28 (Ref 10CFR73.21).No Violation Noted.Major Areas Inspected:Security Program Audit,Physical Barriers, Compensatory Measures & Alarm Stations | Safeguards Contingency Plan |
IR 05000029/1986016 | 31 October 1986 | Insp Rept 50-029/86-16 on 860929-1003.No Violations Noted. Major Areas Inspected:Radiochemical Measurements Program, Including QC of Analytical Measurements & Performance on Radiological Analyses of Split Actual Effluent Samples | |
IR 05000029/1986017 | 2 December 1986 | Insp Rept 50-029/86-17 on 860929-1003.Violation Noted: Failure to Follow Procedures W/Multiple Examples | |
IR 05000029/1986018 | 4 December 1986 | Insp Rept 50-029/86-18 on 861020-24.Major Areas Inspected: Review of Licensee Implementation Program to Establish & Maintain Qualification of Electric Equipment Per 10CFR50.49 | |
IR 05000029/1986019 | 19 March 1987 | Insp Rept 50-029/86-19 on 861007-870126.No Violations Noted. Two Inadequacies Involving Failure to Fully Review Emergency Plan & Insufficient Implementation Procedures for Offsite Dose Calculation Manual Noted | Boric Acid Offsite Dose Calculation Manual Systematic Assessment of Licensee Performance |
IR 05000029/1986020 | 23 June 1987 | Ack Receipt of Informing NRC of Steps Taken to Correct Violation Noted in Insp Rept 50-029/86-20.Meeting Planned for Wk of 870623 in King of Prussia,Pa to Formally Discuss Planned Corrective Actions | |
IR 05000029/1986099 | 23 June 1988 | SALP Rept 50-029/86-99 for 861007-880331 | Fitness for Duty Packing leak High Radiation Area Locked High Radiation Area Missed surveillance Systematic Assessment of Licensee Performance Fuel cladding Overexposure |