m j VERMONT YANKEE NUCLEAR POWER STATION
} MONTHLY STATISTICAL REPORT 81-02 l
- FOR THE MONTH OF FEBRUARY, 1981 4
4 1
4 I
'8203240208 810309 PDR ADOCK 05000271 R PDR
, . ___ . . ~ ___.._ _
l .
OPERATING DATA REPORT DOCKET NO. 50-271 DATE R101oo COMPLETED BY D. Bernard-TELEPHONE 617-872-8100 Ext. 2390 OPERATING STATUS Notes
. Unit Name: Vermont Yankee
. Rzporting Period: February 1981
. Licensed Thermal Power (bMt): 1593
. Namsplate Rating (Gross >Me): 540
. Design Electrical Ratlng(Net SNe): 514 (onen) 504 (closed)
. Maximum Dependable Capacity (Gross FMe): 535
. Maximum Dependable Capacity (Net FMe): 504
. If Changes Occur in Capacity Ratings (Items Number 3 Through 7)Since Last Report, Give Reasons:
. Power Level to Which Restricted,If Any(Net >Me):
- i. Reasons For Restrictions, If Any:
This Month Yr -to-Date Cumulative
. Hours In Reporting Period 672.00 1416.00
. Number Of Hours Reactor Was Critical 672.00 1416.00 58.951.78
. Reactor Reserve Shutdown Hours 0.00 0.00 0.00
. Hours Generator On-Line 672.00 1366.60 56,968.18 l
.. Unit Reserve Shutdown Hours 0.00 0.00 0.00
. Gross Ther=al Energy Generated (FMH) 1.063.277.50 2,054,859.00 80.658.376.00 l
. Gross Electrical Energy Generated (MWH) 363.092.00 694.838.00 26.807.685.00
. Net Electrical Energy Generated (>MH) 348,721.00 666.753.00 25.414.332.00
). Unit Service Factor 100.00 96.51 .
76.94
. Unit Availability Factor 100.00 96.51 76.99
,. Unit Capacity Factor (Using MDC Net) 102.96 93.43 68.15 f.UnitCapacityFactor(UsingDERNet) 100.96 91.61 66.82 f.UnitForcedOutageRate 0.00 1.49 7 ??
. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):
I l
h.IfShut Down At End Of Report Period, Estimated Date of Startup:
f.UnitsInTestStatus(PriortoCo==ercialOperation): Forecast Achieved i INITIAL CRITICALITY
' INITIAL ELECTRICITY l COMMERCIAL OPERATION _ _
Y
/
AVERAGE DAILY UNIT ?OWER LEVEL 2
- .4 DOCKET NO. 50-271 UNIT Vermbnt Yankee DATE 810309 -
1 COMPLETED BY '" .F.J. Burger TELEPHONE' '802-257-7711 Ext. 137 i '.
MONTH February .-
DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net) (MWe-Net)' ,
- 1. 513 17, 522
- 2. 522 18. 522 -
- 3. 521 19. 521
- 4. 522 20. 522
- 5. 521 21. 521
- 6. 521 22, 495
- 7. 491 23. 521
- 8. 521 24. 522
- 9. 522 25. 522
- 10. 521 26. 522
- 11. 522 27. 523
- 12. 522 28. 522
- 13. 521 29.
- 14. 521 30.
- 15. 509 31. --
~
522- /
16.
INSTRUCTIONS:
On this for=at, list the average daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.
- t. .
s UNIT SilUTDOWNS AND POWER FEDUCTIONS. . DOCKET NO 50-271 UNIT NAME Vermont Yankee DATE 810309 REPORT MONTil February COMPLETED BY F.J. Burger TELEPllONE 802-257-7711 Ext. 137 S 12 m o $ $" Cause & Corrective No. ,
Date y ;j g g y 7j g Licen:-e g4 . Action to '
Rep t0 * " " " ' " " * '
x g u e
81-04 810207 S O B 4 N/A IIA TURBINE Power reduction for turbine generator ;
(Power RB CONROD and control rod surveillance. -
reduc-tion) 81-05 810222 F 0 A 4 N/A MB CKTBRK Power reduction due to a loss of control (Power power to the Augmented Off-Cas System reduc- caused by a blown fuse. Fuse replaced tion) and the circuit tested satisfactorily.
l l
/
l 1
F: Forced Reason: Method: Exhibit G- Instructions !
S: Scheduled A-Equipment Failure (Explain) 1- Manual for Preparation of Data B-Maintenance or Test 2- Manual Scram Entry Sheets for Licensee C-Refueling 3- Automatic Scram Event Report (LER) File !
D-Regulatory Restriction 4- Other (Explain) (NUREG 0161) -
E-Operator Training & Lic(nse Ixamination F-Administrative 5 Exhibit I - Same Source G-Operational Error (Explatn)
II-Other (Explain) 7/80
DOCKET NO. 50-271
- UNIT Vermont Tcnkee _
-e
~
DATE 810309 -
- COMT ETED BY F.J. Burger TELEPHONE 802-257-7711 Ext / 137 SAFETY RELATED MAINTENANCE.
NATURE OF MALFUNCTI0tt LER OR OUTAGE EQUIPMENT MAINTENANCE NUMBER CAUSE RESULT CORRECTIVE ACTION "B" SBGT Train lienter Corrective N/A Worn Parts IIcater Control- Replaced Controller MR 80-712 ler Required Frequent Reset-ting.
TIP Machine #3 Contain- Corrective N/A Normal Wear Leakage Replaced "O" Rings ment Penetration MR 80-1051 "A" Reactor Protection Corrective N/A Failed Parts Power Supply Replaced Power Supply System Analog Cabinet MR 81-202 Failure "B" SBGT Train Fan Corrective N/A Worn Parts' Fan Drive Belt Replaced Belt MR 81-222 -
Broken "A" SBGT Train Demister Corrective N/A ' Normal Operation Demister Exhib- Replaced Filter MR 81-227 ited High Diff-crential Press-ure.
ECIC EGR Corrective LER Broken Connector RCIC Inoperative Replaced Connector MR 81-230 81/08/3L Service Water Pump Corrective N/A Normal Wear Packing Leakage Repacked Pump P-71A MR 81-2,49
- o DOCKET NO. 50-271 UNIT Vermont Yankee DATE 810309.
COMPLETED BY F.J. Burger TELEPHONE 802-257-7711. Ext. 137 ,
REPORT MONTH February
SUMMARY
OF OPERATING EXPERIENCES Highlights Vermont Yankee operated at 99.3% of rated thermal power for the month.
Gross electrical generation was 363,092 MWH, or 100% of design electrical capacity.
Operating Summary The following is a chronological description of plant operations including other pertinent items of interest for the month:
2/1/81 At the beginning of the reporting period the plant ada operating at 90% of rated thermal power. Turbine generator surveillance was in progress.
2/7/81 At 0700 hrs, a power reduction was initiated for turbine generator and control rod surveillance. At 1200 hrs. a return to full power was initiated.
2/22/81 At 0020 hrs. a power reduction was initiated due to the loss of of the A0G System control power. Turbine generator surveillance was also completed.
At 0100 hrs. repairs were completed and a return to full power initiated.
2/28/81 At the end of the reporting period the plant was operating at 99.8% of rated thermal power.