ENS 46850
ENS Event | |
---|---|
05:00 May 11, 2011 | |
Title | Agreement State Report - Shutter Stuck Open On Nuclear Gauge |
Event Description | The following information from the State was received by email:
On May 12, 2011, the Agency [Texas Department of Health] was notified by the licensee that while performing a routine inspection of a Ohmart/Vega model SH-F2 nuclear gauge containing 200 milliCuries of Cesium (Cs) - 137 they found the shutter for the device stuck in the open position. The licensee believes the probable cause for the event is a buildup of debris in the operating mechanism of the gauge. The gauge is used for level detection on a vent stack in an area of the plant not routinely occupied. The licensee is lubricating and trying to cycle the shutter frequently. The licensee has contacted a service provider to assist them if needed. No exposure to any personnel has occurred due to this event. Additional information will be provided as it is received in accordance with SA-300. Texas Incident No: I-8849
On May 16, 2011, the licensee reported that the repeated lubrication of the shutter was successful and that the shutter was now working as designed. The report also stated that the event was discovered on May 11, 2011, not May 12, 2011, as first reported. Notified R4DO (Shannon) and FSME (McIntosh). |
Where | |
---|---|
Union Carbide Corporation Port Lavaca, Texas (NRC Region 4) | |
License number: | 00051 |
Organization: | Texas Department Of Health |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+51 h2.125 days <br />0.304 weeks <br />0.0699 months <br />) | |
Opened: | Art Tucker 08:00 May 13, 2011 |
NRC Officer: | John Knoke |
Last Updated: | May 18, 2011 |
46850 - NRC Website | |
Union Carbide Corporation with Agreement State | |
WEEKMONTHYEARENS 569172024-01-09T06:00:0009 January 2024 06:00:00
[Table view]Agreement State Agreement State - Shutter Stuck in Open Position ENS 566212023-07-12T05:00:00012 July 2023 05:00:00 Agreement State Stuck Open Shutter ENS 557012022-01-10T21:35:00010 January 2022 21:35:00 Agreement State Nuclear Gauge Holder Broken Handle ENS 509062015-03-17T05:00:00017 March 2015 05:00:00 Agreement State Agreement State Report - Ohmart Sh-F2 Gauge Shutter Handle Pin Sheared ENS 509052015-03-04T05:00:0004 March 2015 05:00:00 Agreement State Agreement State Report - Ohmart Shlm-Cr3 Cable Detached from Source ENS 502012014-06-16T05:00:00016 June 2014 05:00:00 Agreement State Agreement State Report - Stuck Shutters ENS 500352014-04-11T05:00:00011 April 2014 05:00:00 Agreement State Agreement State Report - Stuck Shutter ENS 468502011-05-11T05:00:00011 May 2011 05:00:00 Agreement State Agreement State Report - Shutter Stuck Open on Nuclear Gauge ENS 468102011-05-01T05:00:0001 May 2011 05:00:00 Agreement State Agreement State Report - Stuck Shutter on Ohmart/Vega Model Gauge ENS 449122009-03-17T05:00:00017 March 2009 05:00:00 Agreement State Agreement State Report - Process Gauge Shutter Handle Broke ENS 444522008-08-29T05:00:00029 August 2008 05:00:00 Agreement State Agreement State Report - Level Gauge Shutter Malfunction 2024-01-09T06:00:00 | |