IA-86-127, Discusses Potential Shrinkage Flaws in Feedwater Check Valve Bodies.If Valve Body Insps Disclose That Internal Shrinkage Cracks Have Propagated to Either Surface,Valves Should Be Replaced Per NUREG-0991 (Ser).Related Info Encl

From kanterella
Revision as of 05:21, 14 December 2020 by StriderTol (talk | contribs) (StriderTol Bot insert)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Discusses Potential Shrinkage Flaws in Feedwater Check Valve Bodies.If Valve Body Insps Disclose That Internal Shrinkage Cracks Have Propagated to Either Surface,Valves Should Be Replaced Per NUREG-0991 (Ser).Related Info Encl
ML20203L541
Person / Time
Site:
Issue date: 03/21/1986
From: Rehm T
NRC OFFICE OF THE EXECUTIVE DIRECTOR FOR OPERATIONS (EDO)
To: Joseph Austin
Office of Nuclear Reactor Regulation
Shared Package
ML20203L508 List:
References
FOIA-86-126, FOIA-86-127, FOIA-86-131, FOIA-86-166, FOIA-86-201, FOIA-86-209, FOIA-86-263, FOIA-86-80, FOIA-86-82, RTR-NUREG-0991, RTR-NUREG-991 NUDOCS 8608270381
Download: ML20203L541 (7)


Text