MONTHYEARNOC-AE-08002378, License Amendment Request for Proposed One-time Exigent Change to Technical Specification 3.7.1.7, Main Feedwater System.2008-12-19019 December 2008 License Amendment Request for Proposed One-time Exigent Change to Technical Specification 3.7.1.7, Main Feedwater System. Project stage: Request ML0835704862008-12-23023 December 2008 Individual Notice of Consideration of Issuance of Amendment, 14-day Exigent Circumstances, Revise TS 3.7.1.7, Main Feedwater System, to Allow One-Time Allowed Outage Time Project stage: Other ML0835704642008-12-23023 December 2008 Letter, Individual Notice of Consideration of Issuance of Amendment, 14-day Exigent Circumstances, Revise TS 3.7.1.7, Main Feedwater System, to Allow One-Time Allowed Outage Time Project stage: Other ML0835902212008-12-24024 December 2008 Acceptance Review E-Mail, One-Time Exigent Change, Extension to Allowed Outage Time for Technical Specification 3.7.1.7, Main Feedwater System Project stage: Acceptance Review ML0900805122008-12-31031 December 2008 E-mail #1, Licensee'S Response to Request for Additional Information, Exigent License Amendment Request, Revise Technical Specification 3.7.1.7, Main Feedwater System, to Allow One-Time Allowed Outage Time (TAC No. ME0271 Project stage: Response to RAI ML0900804872008-12-31031 December 2008 E-mail #2, Licensee'S Response to Request for Additional Information, Exigent License Amendment Request, Revise Technical Specification 3.7.1.7, Main Feedwater System, to Allow One-Time Allowed Outage Time Project stage: Response to RAI NOC-AE-09002379, Response to Request for Additional Information Regarding a Proposed One-Time Exigent Change to Technical Specification 3.7.1.7, Main Feedwater System2009-01-0707 January 2009 Response to Request for Additional Information Regarding a Proposed One-Time Exigent Change to Technical Specification 3.7.1.7, Main Feedwater System Project stage: Response to RAI ML0900706922009-01-16016 January 2009 Issuance of Exigent Amendment No. 176, Revise Technical Specification 3.7.1.7, Main Feedwater System, to Allow One-Time Allowed Outage Time Project stage: Approval 2008-12-24
[Table View] |
|
---|
Category:Letter type:NOC
MONTHYEARNOC-AE-230040, Supplement to Proposed Alternate Frequency to Containment Unbonded Post-Tensioning System Inservice Inspection (Relief Request RR-ENG-4-06)2023-12-14014 December 2023 Supplement to Proposed Alternate Frequency to Containment Unbonded Post-Tensioning System Inservice Inspection (Relief Request RR-ENG-4-06) NOC-AE-230039, Docket Nos. Stn 50-498, Stn 50-499 - Reply to a Notice of Violation, NRC Inspection Report 05000498/2023003 and 05000499/20230032023-12-12012 December 2023 Docket Nos. Stn 50-498, Stn 50-499 - Reply to a Notice of Violation, NRC Inspection Report 05000498/2023003 and 05000499/2023003 NOC-AE-230039, Submittal of Update Foreign Ownership, Control or Influence (FOCI)2023-07-11011 July 2023 Submittal of Update Foreign Ownership, Control or Influence (FOCI) NOC-AE-220039, Physical Security Plan, Training and Qualification Plan, Safeguards Contingency Plan, and Independent Spent Fuel Storage Installation Security Program Revision 252023-02-0606 February 2023 Physical Security Plan, Training and Qualification Plan, Safeguards Contingency Plan, and Independent Spent Fuel Storage Installation Security Program Revision 25 NOC-AE-220038, Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Cask2022-06-23023 June 2022 Independent Spent Fuel Storage Installation Registration of Dry Spent Fuel Storage Cask NOC-AE-210038, Submittal of Operations Quality Assurance Plan Changes QA-089, QA-091, and Revision 252022-01-0404 January 2022 Submittal of Operations Quality Assurance Plan Changes QA-089, QA-091, and Revision 25 NOC-AE-21003858, 10 CFR 50.46 Thirty-Day Report of Significant ECCS Model Changes2021-12-0606 December 2021 10 CFR 50.46 Thirty-Day Report of Significant ECCS Model Changes NOC-AE-21003853, Revised Response to End of Enforcement Discretion and Request for Approval of Alternate Disposal Procedures for Very Low-Level Radioactive Material2021-12-0303 December 2021 Revised Response to End of Enforcement Discretion and Request for Approval of Alternate Disposal Procedures for Very Low-Level Radioactive Material NOC-AE-21003848, Unit 1 Cycle 24 Core Operating Limits Report2021-11-18018 November 2021 Unit 1 Cycle 24 Core Operating Limits Report NOC-AE-21003846, Response to End of Enforcement Discretion and Request for Approval of Alternate Disposal Procedures for Very Low-Level Radioactive Material2021-11-0404 November 2021 Response to End of Enforcement Discretion and Request for Approval of Alternate Disposal Procedures for Very Low-Level Radioactive Material NOC-AE-21003842, 10 CFR 50.59 Summary Report2021-09-23023 September 2021 10 CFR 50.59 Summary Report NOC-AE-21003841, Request for Relief from ASME Section Xl Code Requirements for Weld Examinations (Relief Request RR-ENG-3-25)2021-09-23023 September 2021 Request for Relief from ASME Section Xl Code Requirements for Weld Examinations (Relief Request RR-ENG-3-25) NOC-AE-21003832, Supplement to License Amendment Request to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections2021-09-0909 September 2021 Supplement to License Amendment Request to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections NOC-AE-21003812, Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections2021-08-10010 August 2021 Application to Revise Technical Specifications to Adopt TSTF-577, Revised Frequencies for Steam Generator Tube Inspections NOC-AE-21003825, Update of Foreign Ownership, Control, or Influence Information (FOCI)2021-08-0505 August 2021 Update of Foreign Ownership, Control, or Influence Information (FOCI) NOC-AE-21003824, Update Foreign Ownership, Control, or Influence (FOCI)2021-07-29029 July 2021 Update Foreign Ownership, Control, or Influence (FOCI) NOC-AE-21003823, Update Foreign Ownership Control or Influence (FOCI)2021-07-28028 July 2021 Update Foreign Ownership Control or Influence (FOCI) NOC-AE-21003820, Nuclear Insurance Protection2021-07-20020 July 2021 Nuclear Insurance Protection NOC-AE-21003819, Inservice Inspection Summary Report - 2RE212021-07-15015 July 2021 Inservice Inspection Summary Report - 2RE21 NOC-AE-21003816, Commitment Change Summary Report2021-06-30030 June 2021 Commitment Change Summary Report NOC-AE-21003814, Technical Specification Bases Control Program2021-06-24024 June 2021 Technical Specification Bases Control Program NOC-AE-21003810, Update Foreign Ownership, Control, or Influence (FOCI)- CPS Energy2021-06-17017 June 2021 Update Foreign Ownership, Control, or Influence (FOCI)- CPS Energy NOC-AE-21003811, Update Foreign Ownership, Control, or Influence (FOCI)- Nrg Energy2021-06-17017 June 2021 Update Foreign Ownership, Control, or Influence (FOCI)- Nrg Energy NOC-AE-21003806, Inservice Inspection Program Plan and Inservice Testing Program Snubber Inservice Test Plan for the Fourth Ten-Year Interval2021-05-20020 May 2021 Inservice Inspection Program Plan and Inservice Testing Program Snubber Inservice Test Plan for the Fourth Ten-Year Interval NOC-AE-21003801, Annual Dose Report for 20202021-04-26026 April 2021 Annual Dose Report for 2020 NOC-AE-21003802, 2020 South Texas Project Electric Generating Station Annual Environmental Operating Report2021-04-26026 April 2021 2020 South Texas Project Electric Generating Station Annual Environmental Operating Report NOC-AE-21003804, Operator Licensing Examination Schedule2021-04-21021 April 2021 Operator Licensing Examination Schedule NOC-AE-21003800, Radioactive Effluent Release Report2021-04-19019 April 2021 Radioactive Effluent Release Report NOC-AE-21003799, Changes to South Texas Project Electric Generating Station (STPEGS) Emergency Plan2021-04-15015 April 2021 Changes to South Texas Project Electric Generating Station (STPEGS) Emergency Plan NOC-AE-21003795, Cycle 22 Core Operating Limits Report2021-04-15015 April 2021 Cycle 22 Core Operating Limits Report NOC-AE-21003796, Update Foreign Ownership, Control, or Influence (FOCI)2021-04-15015 April 2021 Update Foreign Ownership, Control, or Influence (FOCI) NOC-AE-21003791, Financial Assurance for Decommissioning - 2021 Update2021-03-31031 March 2021 Financial Assurance for Decommissioning - 2021 Update NOC-AE-21003790, Response to Apparent Violations in NRC Inspection Report 05000498/2020401 and 05000499/2020401: (EA-20-122) (Letter)2021-03-31031 March 2021 Response to Apparent Violations in NRC Inspection Report 05000498/2020401 and 05000499/2020401: (EA-20-122) (Letter) NOC-AE-210037, STP Fire Hazards Analysis Report, Amendment 26 (Redacted)2021-03-30030 March 2021 STP Fire Hazards Analysis Report, Amendment 26 (Redacted) NOC-AE-21003792, STP Fire Hazards Analysis Report, Amendment 26 (Redacted)2021-03-30030 March 2021 STP Fire Hazards Analysis Report, Amendment 26 (Redacted) NOC-AE-200037, License Amendment Request to Revise Technical Specification 3.6.3 to Append a Note and Remove the Index from Technical Specifications2021-03-11011 March 2021 License Amendment Request to Revise Technical Specification 3.6.3 to Append a Note and Remove the Index from Technical Specifications NOC-AE-21003784, Response to Request for Additional Information Regarding 1RE22 Inspection Summary Report for Steam Generator Tubing2021-03-0808 March 2021 Response to Request for Additional Information Regarding 1RE22 Inspection Summary Report for Steam Generator Tubing NOC-AE-21003786, Annual Fitness for Duty Performance Report for 20202021-03-0101 March 2021 Annual Fitness for Duty Performance Report for 2020 NOC-AE-21003785, Evidence of Financial Protection2021-02-23023 February 2021 Evidence of Financial Protection NOC-AE-21003781, Notice Regarding Withdrawal of Funds from Nuclear Decommissioning Trust Subaccounts2021-01-27027 January 2021 Notice Regarding Withdrawal of Funds from Nuclear Decommissioning Trust Subaccounts NOC-AE-21003780, Submittal of Update Foreign Ownership, Control, or Influence (FOCI)2021-01-0707 January 2021 Submittal of Update Foreign Ownership, Control, or Influence (FOCI) NOC-AE-20003778, Changes to South Texas Project Electric Generating Station Emergency Plan2020-12-17017 December 2020 Changes to South Texas Project Electric Generating Station Emergency Plan NOC-AE-20003777, STPNOC Concerns Regarding the Proposed Change to the Evaluated Force-on-Force Inspection Guidance During the COVID-19 Public Health Emergency2020-12-10010 December 2020 STPNOC Concerns Regarding the Proposed Change to the Evaluated Force-on-Force Inspection Guidance During the COVID-19 Public Health Emergency NOC-AE-20003766, Supplement to Change Implementation Date for License Amendment Request to Revise the STPEGS Emergency Plan2020-12-0202 December 2020 Supplement to Change Implementation Date for License Amendment Request to Revise the STPEGS Emergency Plan NOC-AE-20003767, Request for a One-Time Exemption from 10 CFR 73, Appendix 8, Section VI, Subsection C.3.(1)(1) Regarding Annual Force-on-Force (FOF) Exercises, Due to Covid 19 Pandemic2020-11-16016 November 2020 Request for a One-Time Exemption from 10 CFR 73, Appendix 8, Section VI, Subsection C.3.(1)(1) Regarding Annual Force-on-Force (FOF) Exercises, Due to Covid 19 Pandemic NOC-AE-20003765, Inservice Testing Program Description for the Fourth Ten-Year Interval2020-10-28028 October 2020 Inservice Testing Program Description for the Fourth Ten-Year Interval NOC-AE-20003764, 1 RE22 Inspection Summary Report for Steam Generator Tubing2020-10-0707 October 2020 1 RE22 Inspection Summary Report for Steam Generator Tubing NOC-AE-20003762, Supplement to License Amendment Request to Revise Technical Specifications to Adopt TSTF-374, Revision 0, Revision to TS 5.5.13 and Associated TS Bases for Diesel Fuel Oil Using the Consolidated Line Item Improvemen2020-09-22022 September 2020 Supplement to License Amendment Request to Revise Technical Specifications to Adopt TSTF-374, Revision 0, Revision to TS 5.5.13 and Associated TS Bases for Diesel Fuel Oil Using the Consolidated Line Item Improvemen NOC-AE-20003761, Supplement to Exemption Request from 10 CFR 50 Appendix E Due to COVID-19 Pandemic2020-09-10010 September 2020 Supplement to Exemption Request from 10 CFR 50 Appendix E Due to COVID-19 Pandemic NOC-AE-20003760, Update Foreign Ownership. Control. or Influence(FOCI)- Transmittal2020-09-0808 September 2020 Update Foreign Ownership. Control. or Influence(FOCI)- Transmittal 2023-07-11
[Table view] |
Text
Nuclear Operating Company South Texas Pro/ect Electric Generating Station P.O Box 289 Wadsworth.
Texas 77483 -January 7, 2009 NOC-AE-09002379 10 CFR 50.90 10 CFR 50.91 U. S. Nuclear Regulatory Commission Attention:
Document Control Desk One White Flint North 11555 Rockville Pike Rockville, MD 20852-2738 South Texas Project Unit 2 Docket No. STN 50-499 Response to Request for Additional Information Regarding a Proposed One-Time Exigent Change to Technical Specification 3.7.1.7, "Main Feedwater System" (TAC No.' ME027 1)
Reference:
Letter from Charles T. Bowman, STPNOC, to NRC Document Control Desk dated December 19, 2008, "License Amendment Request Proposed One-Time Exigent Change to Technical Specification 3.7.1.7 "Main Feedwater System" (NOC-AE-08002378)
In the referenced letter, STP Nuclear Operating Company (STPNOC) submitted a license amendment request to support a one-time exigent change to Technical Specification 3.7.1.7,"Main Feedwater System". This submittal responds to NRC questions regarding this request received by phone conversation on December 31, 2008. The responses were previously provided by electronic mail on December 31, 2008.There are no new commitments in this submittal.
If you have any questions, please call Ken Taplett at 361-972-8416 or me at 361-972-7454.
I declare under penalty of perjury that the foregoing is true and correct.Executed on _4uc704 4 /Z-.Lc Charles T. Bowman General Manager, Oversight
Attachment:
STPNOC Response to Request for Additional Information STI: 32417990 NOC-AE-09002379 Page 2 cc: (paper copy)(electronic copy)Regional Administrator, Region IV U. S. Nuclear Regulatory Commission 612 East Lamar Blvd, Suite 400 Arlington, Texas 76011-4125 Senior Resident Inspector U. S. Nuclear Regulatory Commission P. 0. Box 289, Mail Code: MN116 Wadsworth, TX 77483 C. M. Canady City of Austin Electric Utility Department 721 Barton Springs Road Austin, TX 78704 Richard A. Ratliff Bureau of Radiation Control Texas Department of State Health Services 1100 West 49th Street Austin, TX 78756-3189 Mohan C. Thadani Senior Project Manager U.S. Nuclear Regulatory Commission One White Flint North (MS 7 D1)11555 Rockville Pike Rockville, MD 20852 A. H. Gutterman, Esquire Morgan, Lewis & Bockius LLP Mohan C. Thadani U. S. Nuclear Regulatory Commission Kevin Howell Catherine Callaway Jim von Suskil NRG South Texas LP Ed Alarcon J. J. Nesrsta R. K. Temple Kevin Pollo City Public Service Jon C. Wood Cox Smith Matthews C. Kirksey City of Austin STI:32417990 NOC-AE-09002379 Attachment Page 1 of 2 STPNOC RESPONSE TO REQUEST FOR ADDITIONAL INFORMATION South Texas Project Unit 2 Docket No. STN 50-499 Response to Request for Additional Information Regarding a Proposed One-Time Exigent Change to Technical Specification 3.7.1.7, "Main Feedwater System" (TAC No. ME0271)The following information was requested by Mohan Thadani, NRC, Senior Project Manager, during phone conversations conducted with Ken Taplett, STPNOC, on December 31, 2008. The responses below were provided by electronic mail on December 31, 2008.NRC Request for Information
- 1: Discuss the containment isolation valve function of the feedwater isolation valves (FWIV) and provide further justification of the one-time extension of the allowed outage time of an inoperable but open FWIV from 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />.STPNOC Response:
The feedwater isolation valves are containment isolation valves that meet General Design Criterion (GDC) 57 of Appendix A to 10 CFR 50. The feedwater isolation valves are in piping that is neither part of the reactor coolant pressure boundary nor connected directly to the containment atmosphere.
The proposed one-time 24-hour action completion time is reasonable, based on operating experience and the low probability of an event occurring during this time period that would require isolation of the main feedwater flow paths to the steam generators.
Although South Texas Project TS 3.6.3, "Containment Isolation Valves", is not applied to an inoperable feedwater isolation valve because this valve has its own TS, the one-time request to extend the allowed outage completion time to 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> is consistent with the Completion Time allowed in TS 3.6.3. South Texas Project TS 3.6.3 allows with one or more isolation valves inoperable, at least one isolation barrier must be maintained operable in the affected penetration that is open and within 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> (if the valve is not restored to an operable status) the affected penetration must be isolated by use of the deactivated automatic valve (in this case, the FWIV)secured in the isolation position.
A GDC 57 closed system meets the requirement of an isolation barrier. In addition, the proposed one-time 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> allowed outage time is more conservative than ITS Condition C of TS 3.6.3, "Containment Isolation Valves", for one or more penetrations inoperable (applicable to penetration flow paths with only one containment isolation valve and a closed system) that allows a 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> allowed outage time for an inoperable valve in this type of penetration.
NOC-AE-09002379 Attachment Page 2 of 2 NRC Request for Information
- 2: STP-2 relies upon stopping the SG Feedwater Pump and the feedwater control valve as compensatory action for a failure of the feedwater isolation valve.The accident analysis indicates the feedwater isolation valve is required to close in 13 seconds to limit the maximum containment pressure for a main steamline break in containment.
We cannot determine from the UFSAR whether the stopping time for the SG feedwater pumps and the closing of the feedwater control valve is within the 13 seconds assumed in the accident analysis.
If they are not, we cannot find any reference to a containment pressure accident analysis for a main steamline break in containment with feedwater isolation times based on the control valve and feedwater pump closing and stopping times. We would expect the analysis has already have been performed as part of their single failure analysis.Two questions:
- 1) Is the isolation of feedwater to the steam generators using the stopping of the steam generator feedwater pumps and the closing of the feedwater control valves within the 13 second closing time assumed for the feedwater isolation valve as used in the accident analysis discussed in UFSAR Section 6.2?2) If the isolation of feedwater to the steam generators by the stopping of the steam generator feedwater pumps and the closing of the feedwater control valves is greater than the 13 second closing time assumed for the feedwater isolation valve, what is the peak containment pressure for a main steamline break in containment?
Note: The 72 hour8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br /> AOT for containment isolation valves as listed in the WOG standard technical specifications appears to be based on minimizing radiological leakage from containment.
We haven't found any discussion in the bases on restricting feedwater inventory to the steam generators during a main steamline break in containment to limit maximum containment pressures.
STPNOC Response:
The accident analysis, discussed in UFSAR Section 6.2, credits feedwater isolation within 13 .seconds of feedwater isolation signal initiation to limit the maximum containment pressure for a main steamline break in containment.
The feedwater control valves receive a feedwater isolation signal and are designed to close in sufficient time to meet the 13 seconds assumed in the accident analysis.
The closure time of the feedwater control valves are verified every refueling cycle by plant surveillance procedures.
Therefore, the feedwater control valves function as a backup feature to limit the maximum containment pressure for a main steamline break in containment.
The accident analysis discussed in UFSAR Section 6.2 does not credit the stopping of the steam generator feedwater pumps.