ML20203K555

From kanterella
Revision as of 11:43, 31 December 2020 by StriderTol (talk | contribs) (StriderTol Bot change)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
Notice of Violation from Insp on 860728-29
ML20203K555
Person / Time
Issue date: 08/14/1986
From: Wiedeman D
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
To:
Shared Package
ML20203K530 List:
References
99990003-86-01, 99990003-86-1, NUDOCS 8608200337
Download: ML20203K555 (1)


Text

. .

5 NOTICE OF VIOLATION Scientific Measurement Systems, Inc. License No. Texas 6-2696 As a result of the inspection conducted on July 28-29, 1986, and in accordance with 10 CFR Part 2, Appendix C - General Statement of Policy and Procedure for NRC Enforcement Actions (1985), the following violation was identified:

10 CFR 71.12(a)(c)(1)(3) requires each licensee who transports Type B quantities of licensed material in NRC approved containers to register in writing with the Director, Office of Nuclear Safety and Safeguards, U.S. Nuclear Regulatory Commission, Washington, D.C. 20555, as a user of the NRC approved containers.

Contrary to this requirement, the licensee failed to register in writing with the Commission as a user of a container approved by the NRC used to transoort Type B quantities of cobalt-60 to a facility located in Defiance, Ohio on July 15, 1986.

This is a Severity Level IV violation (Supplement V).

Pursuant to the provisions of 10 CFR 2.201, you are required to submit to this office within thirty days of the date of this Notice a written statement or explanation in reply, including for each violation: (1) corrective action taken and the -asults achieved; (2) corrective action to be taken to avoid further violations; and (3) the date when full compliance will be achieved.

Consideration may be given to extending your response time for good cause shown.

/

s' AUG 141986 ./. ph Dated U.'G. Wiedeman, Chief Nuclear Materials Safety Section 1 860E2OO337 860814 IE GA999 EMV*****

99990003 PDR