- 05000325/LER-1982-017, Forwards LER 82-017/03L-0 (← links)
- 05000325/LER-1982-014, Forwards LER 82-014/03L-0 (← links)
- 05000325/LER-1982-138, Forwards LER 82-138/03L-0 (← links)
- 05000325/LER-1982-116, Forwards LER 82-116/03L-0 (← links)
- 05000325/LER-1982-111, Forwards LER 82-111/03L-0 (← links)
- 05000325/LER-1982-115, Forwards LER 82-115/03L-0 (← links)
- 05000325/LER-1982-114, Forwards LER 82-114/03L-0 (← links)
- 05000325/LER-1982-113, Forwards LER 82-113/03L-0 (← links)
- 05000325/LER-1982-136, Forwards LER 82-136/03L-0 (← links)
- 05000325/LER-1982-107, Forwards LER 82-107/03L-0 (← links)
- 05000325/LER-1982-112, Forwards LER 82-112/01T-0 (← links)
- 05000325/LER-1981-053, Updated LER 81-053/03L-1:on 810922,during Reactor Startup, Reactor Recirculation Pump 1B Tripped.Caused by Spurious Trip Signal from ATWS Low Water Level Instrument B21-LTM- NO24B-2.Instrument replaced.W/840329 Ltr (← links)
- 05000325/LER-1981-055, Updated LER 81-055/03L-1:on 820622,drywell Equipment Drain Flow Integrator 1-G16-FQ-K603 Continuously Indicated Dwed Sump Flow W/No Pumps Running.Caused by Water Being Introduced Into Pneumatic calibrator.W/840328 Ltr (← links)
- 05000325/LER-1995-016, Forwards LER 95-016 Re ESF Actuation Due to Malfunction of Reactor Protection Sys Electrical Protection Assembly Logic Card (← links)
- 05000325/LER-1995-014, Forwards LER 95-014 Re Unplanned Esfa (← links)
- 05000325/LER-1983-063, Updated LER 83-063/03L-1:on 831203,reactor Water Cleanup Sys (Rwcs) Differential Flow Indicator 1-G31-R615 Showed Erroneous Indication.On 831207,spurious Rwcs Alarm Annunciated.Caused by Air in Sensing lines.W/840222 Ltr (← links)
- 05000325/LER-1983-057, Updated LER 83-057/03L-1:on 831119,during Unit Power Performance,Temp Recorder TR-1258 Printed Erratically.Caused by Dirty Electrical Contacts in Control Board Timing Relay. Contacts Cleaned & Returned to svc.W/840222 Ltr (← links)
- 05000325/LER-1995-001, Forwards LER 95-001 Re Two Inoperable Control Rod Accumulators Result in Entry Into TS 3.0.3 (← links)
- 05000325/LER-1995-012, Forwards LER 95-012 Re Reactor Water Cleanup Sys Isolation Due to Filter Leakage (← links)
- 05000325/LER-1995-009, Forwards LER 95-009 Which Fulfills Requirement for Written Rept within 30 Days of Reportable Occurrence (← links)
- 05000325/LER-1995-010, Forwards LER 95-010 Re Loss of RPS Bus a Power & Associated ESF Actuations (← links)
- 05000325/LER-1995-007, Forwards LER 95-007 Re Safety Relief Valves Tested at Wyle Lab Exceeding TS Setpoint Limits (← links)
- 05000325/LER-1995-008, Forwards LER 95-008 Re Spurious Actuation of Primary Containment Isolation Sys Group 6 Valves (← links)
- 05000325/LER-1983-003, Forwards LER 83-003/03L-0 (← links)
- 05000325/LER-1982-044, Forwards Updated LER 82-044/03L-2 (← links)
- 05000325/LER-1982-143, Forwards Updated LER 82-143/03L-1 (← links)
- 05000325/LER-1982-152, Forwards LER 82-152/03L-0 (← links)
- 05000325/LER-1995-002, Forwards LER 95-002 Re Multiple Chlorine Sensors Used for Control Bldg Isolation Logic Found to Be Outside TS Tolerances During Routine Calibr (← links)
- 05000325/LER-1982-122, Supplemental LER 82-122/03L-1:on 821030 & 1104,reactor Recirculation Pump 1A Tripped.On 821101 & 04,reactor Recirculation Pump 1B Tripped.Caused by Spurious Action of ATWS Instrument B21-PS-N045C (← links)
- 05000325/LER-1978-085, Forwards LER 78-085/03L-0 (← links)
- 05000325/LER-1978-090, Forwards LER 78-090/03L-0 (← links)
- 05000325/LER-1995-004, Forwards LER 95-004 Re Plant Mod Wire Lift Results in Isolation of Sys Not Properly Separated from Mod Work (← links)
- 05000325/LER-1991-021, Forwards LER 91-021-00 Inadvertently Submitted W/O Date (← links)
- 05000325/LER-1983-034, Updated LER 83-034/01T-1:on 830811,following Extended Maint & Refueling Outage,Instrument Isolation Valves to 1CAC-PDS-4222 & 4223 Discovered Closed.Caused by Cancelation of Equipment Clearance.Valves Reopened (← links)
- 05000325/LER-1983-045, Updated LER 83-045/03L-2:on 830919 & 24,inboard PCIV Steam Supply Valve ES1-F007 to RCIC Sys Would Not Completely Reopen.Caused by Loose Limitorque Motor Operator Spring Pack (← links)
- 05000325/LER-1982-140, Forwards LER 82-140/03L-0 (← links)
- 05000325/LER-1982-139, Forwards LER 82-139/03L-0 (← links)
- 05000325/LER-1983-017, Updated LER 83-017/03L-1:on 830326-28 & 0402,listed Control Rods Had No Indications for Identified Positions.Caused by Loose Prototypic Inlet Piping Connectors Due to Undervessel Work.Connectors Will Be Properly Fastened (← links)
- 05000325/LER-1983-014, Forwards LER 83-014/03L-0 (← links)
- 05000325/LER-1983-012, Forwards LER 83-012/03L-0 (← links)
- 05000325/LER-1983-013, Forwards LER 83-013/03L-0 (← links)
- 05000325/LER-1983-011, Forwards LER 83-011/03L-0 (← links)
- 05000325/LER-1982-108, Updated LER 82-108/03L-1:on 821010 & 14,while Performing Automatic Depressurization Sys Valve Operability Test,Valves 1-B21-F013J & 1-B21-F013D & E Failed to Reclose.Caused by Faulty Spring.Valves Replaced (← links)
- 05000325/LER-1984-009, Informs That Rept on LER 84-009-01 Re 840613 Discovery of Potential for Core Spray Sys Pump Inoperability Will Be Submitted by 840727,not 840713 as Originally Indicated (← links)
- 05000325/LER-1983-015, Forwards LER 83-015/01T-0 (← links)
- 05000325/LER-1983-007, Forwards Updated LER 83-007/03L-1 (← links)
- 05000325/LER-1983-006, Forwards Updated LER 83-006/03L-1 (← links)
- 05000325/LER-1982-101, Forwards LER 82-101/03L-0 (← links)
- 05000325/LER-1982-068, Forwards LER 82-068/03L-0 (← links)
- 05000325/LER-1982-057, Forwards LER 82-057/03L-0 (← links)