CY-04-155, Registration of Spent Fuel Dry Cask in Use at the Plant Independent Spent Fuel Storage Installation (ISFSI): Difference between revisions
StriderTol (talk | contribs) (StriderTol Bot insert) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
| Line 16: | Line 16: | ||
=Text= | =Text= | ||
{{#Wiki_filter:CONNECTICUT | {{#Wiki_filter:CONNECTICUT YANKEE ATOMIC POWER COMPANY HADDAM NECK PLANT 362 INJUN HOLLOW ROAD | ||
* EAST HAMPTON, CT 06424-3099 CY-04-155 Licenseth.DPR-61 Docket No. 50-213 Docket No. 72-0039 Re: 10 CFR 72.212 Director, Spent Fuel Project Office, | * EAST HAMPTON, CT 06424-3099 CY-04-155 Licenseth.DPR-61 Docket No. 50-213 Docket No. 72-0039 Re: 10 CFR 72.212 Director, Spent Fuel Project Office, | ||
-~~--Office of Nuclear Material-Safety and Safeguards------------______ | -~~--Office of Nuclear Material-Safety and Safeguards------------______ | ||
U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555 Haddam Neck Plant Registration of Spent Fuel Drv Cask in use at the Haddam Neck Plant (HNP) Independent Spent Fuel Storaae Installation (ISFSI) c.d | U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555 Haddam Neck Plant Registration of Spent Fuel Drv Cask in use at the Haddam Neck Plant (HNP) Independent Spent Fuel Storaae Installation (ISFSI) a c.d i c | ||
.it.. | |||
In accordance0'with10 CFR72.21 2(b)(1 )(ii), Connecticut Yankee Atomic Power Company (CYAPCO) is registering the use of a spent fuel dry cask to store spent fuel under a 10 CFR Part 72 general license at the HNP ISFSI. | In accordance0'with10 CFR72.21 2(b)(1 )(ii), Connecticut Yankee Atomic Power Company (CYAPCO) is registering the use of a spent fuel dry cask to store spent fuel under a 10 CFR Part 72 general license at the HNP ISFSI. | ||
Licensee's Name: Connecticut Yankee Atomic Power Company Licensee's Address: Haddam Neck Plant 362 Injun Hollow Road East Hampton, CT 06424-3099 Reactor License Number: DPR-61 Reactor Docket No.: 50-213 ISFSI Docket No.: 72-0039 Contact-Name and | Licensee's Name: Connecticut Yankee Atomic Power Company Licensee's Address: Haddam Neck Plant 362 Injun Hollow Road East Hampton, CT 06424-3099 Reactor License Number: DPR-61 Reactor Docket No.: 50-213 ISFSI Docket No.: 72-0039 Contact-Name and | ||
| Line 26: | Line 26: | ||
==Title:== | ==Title:== | ||
G. P. van Noordennen; Regulatory Affairs Manager Cask Certification No.' Cerificdtae of Compliance 1025; Amendment 'No:3, October 1, 2003 | G. P. van Noordennen; Regulatory Affairs Manager Cask Certification No.' Cerificdtae of Compliance 1025; Amendment 'No:3, October 1, 2003 | ||
.'-t. | |||
.':'I a.={.f.Bt5 | |||
Document Control Center CY-04-155/ Page 2 Cask Model No.: NAC-MPC Cask Identification Nos.: Transportable storage canister (TSC) Identification No. | Document Control Center CY-04-155/ Page 2 Cask Model No.: NAC-MPC Cask Identification Nos.: Transportable storage canister (TSC) Identification No. | ||
CY-MPC-TSC-414-23 Vertical Concrete Cask (VCC) Identification No.: CY-VCC-23 Date in Service: July 22, 2004 There are no regulatory commitments contained in this letter. | CY-MPC-TSC-414-23 Vertical Concrete Cask (VCC) Identification No.: CY-VCC-23 Date in Service: July 22, 2004 There are no regulatory commitments contained in this letter. | ||
If you should have any questions regarding this submittal, please contact me at (860) 267-3938. | If you should have any questions regarding this submittal, please contact me at (860) 267-3938. | ||
Sincerely, Gary | Sincerely, Gary ouca Date Director Nuclear Safety/Regulatory Affairs cc: | ||
H. J. Miller, NRC Region 1 Administrator T. B. Smith, NRC Project Manager, Haddam Neck Plant R. R. Bellamy, Chief, Decommissioning and Laboratory Branch, NRC Region 1 E. L. Wilds, Jr., Director, CT DEP, Monitoring and Radiation Division}} | |||
Latest revision as of 01:56, 16 January 2025
| ML042170155 | |
| Person / Time | |
|---|---|
| Site: | Haddam Neck, 07201025 File:Connecticut Yankee Atomic Power Co icon.png |
| Issue date: | 07/28/2004 |
| From: | Bouchard G Connecticut Yankee Atomic Power Co |
| To: | Document Control Desk, NRC/NMSS/SFPO |
| References | |
| -RFPFR, CY-04-155 | |
| Download: ML042170155 (2) | |
Text
CONNECTICUT YANKEE ATOMIC POWER COMPANY HADDAM NECK PLANT 362 INJUN HOLLOW ROAD
- EAST HAMPTON, CT 06424-3099 CY-04-155 Licenseth.DPR-61 Docket No. 50-213 Docket No. 72-0039 Re: 10 CFR 72.212 Director, Spent Fuel Project Office,
-~~--Office of Nuclear Material-Safety and Safeguards------------______
U.S. Nuclear Regulatory Commission Attention: Document Control Desk Washington, DC 20555 Haddam Neck Plant Registration of Spent Fuel Drv Cask in use at the Haddam Neck Plant (HNP) Independent Spent Fuel Storaae Installation (ISFSI) a c.d i c
.it..
In accordance0'with10 CFR72.21 2(b)(1 )(ii), Connecticut Yankee Atomic Power Company (CYAPCO) is registering the use of a spent fuel dry cask to store spent fuel under a 10 CFR Part 72 general license at the HNP ISFSI.
Licensee's Name: Connecticut Yankee Atomic Power Company Licensee's Address: Haddam Neck Plant 362 Injun Hollow Road East Hampton, CT 06424-3099 Reactor License Number: DPR-61 Reactor Docket No.: 50-213 ISFSI Docket No.: 72-0039 Contact-Name and
Title:
G. P. van Noordennen; Regulatory Affairs Manager Cask Certification No.' Cerificdtae of Compliance 1025; Amendment 'No:3, October 1, 2003
.'-t.
.':'I a.={.f.Bt5
Document Control Center CY-04-155/ Page 2 Cask Model No.: NAC-MPC Cask Identification Nos.: Transportable storage canister (TSC) Identification No.
CY-MPC-TSC-414-23 Vertical Concrete Cask (VCC) Identification No.: CY-VCC-23 Date in Service: July 22, 2004 There are no regulatory commitments contained in this letter.
If you should have any questions regarding this submittal, please contact me at (860) 267-3938.
Sincerely, Gary ouca Date Director Nuclear Safety/Regulatory Affairs cc:
H. J. Miller, NRC Region 1 Administrator T. B. Smith, NRC Project Manager, Haddam Neck Plant R. R. Bellamy, Chief, Decommissioning and Laboratory Branch, NRC Region 1 E. L. Wilds, Jr., Director, CT DEP, Monitoring and Radiation Division