{{#Wiki_filter:NRC REGION III INITIAL LICENSE EXAM JOB PERFORMANCE MEASURE JPM:         RO/SRO ADMIN 1a TITLE:       DETERMINE QUADRANT POWER TILT PER PO-3 CANDIDATE: _____________________________________________
{{#Wiki_filter:NRC REGION III INITIAL LICENSE EXAM JOB PERFORMANCE MEASURE JPM:
EXAMINER: _____________________________________________
RO/SRO ADMIN 1a TITLE:
DETERMINE QUADRANT POWER TILT PER PO-3 CANDIDATE:
EXAMINER:  


JPM RO SRO ADMIN 1a JOB PERFORMANCE MEASURE DATA PAGE Task: Determine Quadrant Power Tilt PER PO-3 Alternate Path: N/A Facility JPM #: PL-OPS-ENG-014J K/A: G2.1.7       Importance: RO: 4.4 SRO: 4.7 K/A Statement: Ability to evaluate plant performance and make operational judgments based on operating characteristics, reactor behavior, and instrument interpretation.
JPM RO SRO ADMIN 1a PALISADES NUCLEAR PLANT Page 2 of 9 July 2008 JOB PERFORMANCE MEASURE DATA PAGE Task: Determine Quadrant Power Tilt PER PO-3 Alternate Path: N/A Facility JPM #: PL-OPS-ENG-014J K/A: G2.1.7 Importance: RO: 4.4 SRO: 4.7 K/A Statement: Ability to evaluate plant performance and make operational judgments based on operating characteristics, reactor behavior, and instrument interpretation.
Task Standard: Correctly calculate a Quadrant Power Tilt Per PO-3 Preferred Evaluation Location: Simulator         __X__   In Plant   _____
Task Standard: Correctly calculate a Quadrant Power Tilt Per PO-3 Preferred Evaluation Location: Simulator
Preferred Evaluation Method:       Perform     __X__   Simulate   _____
__X__
In Plant Preferred Evaluation Method:
Perform
__X__
Simulate  


==References:==
==References:==
PO-3, Alternate Incore and Excore Applications Validation Time:12 minutes         Time Critical:     NO Candidate: ________________________________________________
PO-3, Alternate Incore and Excore Applications Validation Time: 12 minutes Time Critical:
Time Start: ________         Time Finish:       ________
NO Candidate: ________________________________________________
Performance Time:       ________ minutes Performance Rating:     SAT______         UNSAT ______
Time Start: ________
Time Finish:
Performance Time:
________ minutes Performance Rating:
SAT______
UNSAT ______
Comments:
Comments:
Examiner: _______________________________                 Date:   ______________
Examiner: _______________________________
Signature PALISADES NUCLEAR PLANT                    Page 2 of 9                          July 2008
Date:
Signature  


JPM RO SRO ADMIN 1a EXAMINER COPY ONLY Tools/Equipment/Procedures Needed:
JPM RO SRO ADMIN 1a PALISADES NUCLEAR PLANT Page 3 of 9 July 2008 EXAMINER COPY ONLY Tools/Equipment/Procedures Needed:
PO-3, Attachment 2, Rev. 2 Also see Simulator Operator Instructions (last page of this document).
PO-3, Attachment 2, Rev. 2 Also see Simulator Operator Instructions (last page of this document).
READ TO CANDIDATE DIRECTION TO CANDIDATE:
READ TO CANDIDATE DIRECTION TO CANDIDATE:
Line 40: Line 52:
* CRD #11 has dropped into the core.
* CRD #11 has dropped into the core.
INITIATING CUES:
INITIATING CUES:
* During performance of PO-3, Alternate Incore and Excore Applications, the Control Room Supervisor directs you to calculate Excore Quadrant Power Tilt utilizing Power Range NI Channels on Panel C-06.
* During performance of PO-3, Alternate Incore and Excore Applications, the Control Room Supervisor directs you to calculate Excore Quadrant Power Tilt utilizing Power Range NI Channels on Panel C-06.  
PALISADES NUCLEAR PLANT                      Page 3 of 9                              July 2008


JPM RO SRO ADMIN 1a Proc. Step             TASK ELEMENT 1                                       STANDARD                       Grade PO-3, Attachment 2, Excore Quadrant Power Correct Procedure located n/a                                                      Tilt, located.                                   S U Comment:
JPM RO SRO ADMIN 1a PALISADES NUCLEAR PLANT Page 4 of 9 July 2008 Proc. Step TASK ELEMENT 1 STANDARD Grade n/a Correct Procedure located PO-3, Attachment 2, Excore Quadrant Power Tilt, located.
Notes:     Evaluator provides candidate with a Working Copy.
S U Comment:
Proc. Step             TASK ELEMENT 2                                       STANDARD                       Grade Lower and upper excore readings from the PPC using NI5L, NI5U, NI6L, NI6U, NI7L, NI7U, NI8L Obtain lower and upper excore readings          and NI8U or from the Upper and Lower NI 5.2.1    as required. (SAL, SBL, SCL, SDL and SAU,      Detector meters on EC-06 are entered on PO-3,     S U SBU, SCU, SDU).                                Attachment 2, within +/-1% (0.01) of the answer key.
Notes:
Comment:
Evaluator provides candidate with a Working Copy.
CRITICAL STEP Proc. Step             TASK ELEMENT 3                                       STANDARD                       Grade Lower + Upper excore readings (SA, SB, SC, SD)
Proc. Step TASK ELEMENT 2 STANDARD Grade 5.2.1 Obtain lower and upper excore readings as required. (SAL, SBL, SCL, SDL and SAU, SBU, SCU, SDU).
Calculate the sum from the Lower + Upper summed and entered on PO-3, Attachment #2, 5.2.1    excore readings (SA, SB, SC, SD                                                                  S U within +/-1% (0.01) of the answer key.
Lower and upper excore readings from the PPC using NI5L, NI5U, NI6L, NI6U, NI7L, NI7U, NI8L and NI8U or from the Upper and Lower NI Detector meters on EC-06 are entered on PO-3,, within +/-1% (0.01) of the answer key.
Comment:
S U Comment:
CRITICAL STEP PALISADES NUCLEAR PLANT                          Page 4 of 9                                      July 2008
CRITICAL STEP Proc. Step TASK ELEMENT 3 STANDARD Grade 5.2.1 Calculate the sum from the Lower + Upper excore readings (SA, SB, SC, SD Lower + Upper excore readings (SA, SB, SC, SD) summed and entered on PO-3, Attachment #2, within +/-1% (0.01) of the answer key.
S U Comment:
CRITICAL STEP  


JPM RO SRO ADMIN 1a Proc. Step             TASK ELEMENT 4                                     STANDARD                       Grade
JPM RO SRO ADMIN 1a PALISADES NUCLEAR PLANT Page 5 of 9 July 2008 Proc. Step TASK ELEMENT 4 STANDARD Grade 5.2.1
: 1. Calculate the sum of all excore           Sum of all excores reading divided by 4 readings divided by 4:                  calculated and entered on PO-3, Attachment 2, 5.2.1    (S =  all detectors/4).                    within +/- 1% (0.01) of the answer key.               S U Comment:
: 1. Calculate the sum of all excore readings divided by 4:
CRITICAL STEP Proc. Step             TASK ELEMENT 5                                     STANDARD                       Grade Using the formula TEX = [(SX - S)/S], calculate the tilt for each Quadrant, within +/-1% (0.01) of 5.2.1    Calculate the Quadrant Tilt.                the answer key.                                     S U Comment:
(S = all detectors/4).
Evaluator: Acceptance criteria is all four Quadrant Tilts should add up to zero (0) +/- 0.01 CRITICAL STEP Proc. Step             TASK ELEMENT 6                                     STANDARD                       Grade Have another qualified individual verify the Have calculations verified.
Sum of all excores reading divided by 4 calculated and entered on PO-3, Attachment 2, within +/- 1% (0.01) of the answer key.
5.2.1                                                calculations.                                      S U Comment:
S U Comment:
Notes: Evaluator CUE: State to operator that someone else will verify the calculation.
CRITICAL STEP Proc. Step TASK ELEMENT 5 STANDARD Grade 5.2.1 Calculate the Quadrant Tilt.
PALISADES NUCLEAR PLANT                      Page 5 of 9                                        July 2008
Using the formula TEX
= [(SX - S)/S], calculate the tilt for each Quadrant, within +/-1% (0.01) of the answer key.
S U Comment:
Evaluator: Acceptance criteria is all four Quadrant Tilts should add up to zero (0) +/- 0.01 CRITICAL STEP Proc. Step TASK ELEMENT 6 STANDARD Grade 5.2.1 Have calculations verified.
Have another qualified individual verify the calculations.
S U Comment:
Notes: Evaluator CUE: State to operator that someone else will verify the calculation.  


JPM RO SRO ADMIN 1a Proc. Step             TASK ELEMENT 7                                     STANDARD                       Grade Notify the CRS that Excore Quadrant Operator notifies CRS of completion of PO-3, Power Tilt has been completed per PO-3, n/a                                                  Attachment 2, Excore Quadrant Power Tilt         S U Attachment 2.
JPM RO SRO ADMIN 1a PALISADES NUCLEAR PLANT Page 6 of 9 July 2008 Proc. Step TASK ELEMENT 7 STANDARD Grade n/a Notify the CRS that Excore Quadrant Power Tilt has been completed per PO-3,.
Comment:
Operator notifies CRS of completion of PO-3,, Excore Quadrant Power Tilt S U Comment:
END OF TASK PALISADES NUCLEAR PLANT                      Page 6 of 9                                      July 2008
END OF TASK  


JPM RO SRO ADMIN 1a CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER TO UPON COMPLETION OF TASK)
JPM RO SRO ADMIN 1a PALISADES NUCLEAR PLANT Page 7 of 9 July 2008 CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER TO UPON COMPLETION OF TASK)
INITIAL CONDITIONS:
INITIAL CONDITIONS:
* Plant was at full power.
* Plant was at full power.
Line 70: Line 89:
* CRD #11 has dropped into the core.
* CRD #11 has dropped into the core.
INITIATING CUES:
INITIATING CUES:
* During performance of PO-3, Alternate Incore and Excore Applications, the Control Room Supervisor directs you to calculate Excore Quadrant Power Tilt utilizing Power Range NI Channels on Panel C-06.
* During performance of PO-3, Alternate Incore and Excore Applications, the Control Room Supervisor directs you to calculate Excore Quadrant Power Tilt utilizing Power Range NI Channels on Panel C-06.  
PALISADES NUCLEAR PLANT              Page 7 of 9                              July 2008


JPM RO SRO ADMIN 1a SIMULATOR OPERATOR INSTRUCTIONS SIMULATOR SET UP:
JPM RO SRO ADMIN 1a PALISADES NUCLEAR PLANT Page 8 of 9 July 2008 SIMULATOR OPERATOR INSTRUCTIONS SIMULATOR SET UP:
Simulator Setup Instructions:
Simulator Setup Instructions:
* Full power IC
* Full power IC
Line 79: Line 97:
* When plant has stabilized, freeze the Simulator and SNAP. ***See NOTE #1 below.
* When plant has stabilized, freeze the Simulator and SNAP. ***See NOTE #1 below.
* Use PO-3, Attachment 2 and record/calculate from the Upper and Lower NI Detector meters on EC-06) and use as answer key.
* Use PO-3, Attachment 2 and record/calculate from the Upper and Lower NI Detector meters on EC-06) and use as answer key.
* Leave the Simulator in freeze during performance of this JPM to ensure that the conditions will not change PALISADES NUCLEAR PLANT              Page 8 of 9                            July 2008
* Leave the Simulator in freeze during performance of this JPM to ensure that the conditions will not change  


JPM RO SRO ADMIN 1a Excore       Lower Reading(%)       Upper Reading(%)        Lower + Upper      S = ( All Detectors)/4        Excore Quadrant Tilt SAL, SBL, SCL, SDL     SAU, SBU, SCU, SDU     SA, SB, SC, SD     = (SA + SB + SC + SD)/4       TEA, TEB, TEC, TED 5 (CH A)       SAL =                 SAU =                 SA = SAL + SAU                                     TEA = [(SA-S)/S]           QUAD 1 50.5                  50 100.5                                                  .0565 6 (CH B)       SBL =                 SBU =                 SB = SBL + SBU                                     TEB = [(SB-S)/S]           QUAD 3 95.125 40                    39 79                                                      -.1695 7 (CH C)       SCL =                 SCU =                 SC = SCL + SCU                                     TEC = [(SC-S)/S]           QUAD 4 50                    50 100                                                    .0512 8 (CH D)       SDL =                 SDU =                 SD = SDL + SDU                                     TED = [(SD-S)/S]           QUAD 2 52                    49 101                                                    .0618 NOTE:         The four QPTs should sum to approximately zero.
JPM RO SRO ADMIN 1a PALISADES NUCLEAR PLANT Page 9 of 9 July 2008 Excore Lower Reading(%)
SAL, SBL, SCL, SDL Upper Reading(%)
SAU, SBU, SCU, SDU Lower + Upper SA, SB, SC, SD S = ( All Detectors)/4
= (SA + SB + SC + SD)/4 Excore Quadrant Tilt TEA, TEB, TEC, TED 5 (CH A)
SAL =
50.5 SAU =
50 SA = SAL + SAU 100.5 95.125 TEA = [(SA-S)/S]  
.0565 QUAD 1 6 (CH B)
SBL =
40 SBU =
39 SB = SBL + SBU 79 TEB = [(SB-S)/S]  
-.1695 QUAD 3 7 (CH C)
SCL =
50 SCU =
50 SC = SCL + SCU 100 TEC = [(SC-S)/S]  
.0512 QUAD 4 8 (CH D)
SDL =
52 SDU =
49 SD = SDL + SDU 101 TED = [(SD-S)/S]  
.0618 QUAD 2 NOTE:
The four QPTs should sum to approximately zero.
Comments:
Comments:
Performed By: ____Pat Person_________________________________                           Date: _____Today__________           Time: _______Now______
Performed By: ____Pat Person_________________________________
Calculations Verified By: _____________________________________________________                                               Date: _______________
Date: _____Today__________ Time: _______Now______
Calculations Verified By: _____________________________________________________
Date: _______________
After calculations are verified, forward to Reactor Engineering Supervisor or designee for final review.
After calculations are verified, forward to Reactor Engineering Supervisor or designee for final review.
Reactor Engineering Supervisor or designee: _______________________________________                                           Date: _______________
Reactor Engineering Supervisor or designee: _______________________________________
ANSWER KEY                 ANSWER KEY               ANSWER KEY               ANSWER KEY                 ANSWER KEY           ANSWER KEY PALISADES NUCLEAR PLANT                            Page 9 of 9                                          July 2008}}
Date: _______________
ANSWER KEY ANSWER KEY ANSWER KEY ANSWER KEY ANSWER KEY ANSWER KEY}}

Latest revision as of 11:35, 14 January 2025

NRC Region III, Initial License Exam, Job Performance Measure, JPM: Ro/Sro Admin 1A, Title: Determine Quadrant Power Tilt Per PO-3
ML091520264
Person / Time
Site: Palisades Entergy icon.png
Issue date: 07/07/2008
From:
NRC/RGN-III
To:
Entergy Nuclear Palisades
Shared Package
ML082200311 List:
References
Download: ML091520264 (9)


Text

NRC REGION III INITIAL LICENSE EXAM JOB PERFORMANCE MEASURE JPM:

RO/SRO ADMIN 1a TITLE:

DETERMINE QUADRANT POWER TILT PER PO-3 CANDIDATE:

EXAMINER:

JPM RO SRO ADMIN 1a PALISADES NUCLEAR PLANT Page 2 of 9 July 2008 JOB PERFORMANCE MEASURE DATA PAGE Task: Determine Quadrant Power Tilt PER PO-3 Alternate Path: N/A Facility JPM #: PL-OPS-ENG-014J K/A: G2.1.7 Importance: RO: 4.4 SRO: 4.7 K/A Statement: Ability to evaluate plant performance and make operational judgments based on operating characteristics, reactor behavior, and instrument interpretation.

Task Standard: Correctly calculate a Quadrant Power Tilt Per PO-3 Preferred Evaluation Location: Simulator

__X__

In Plant Preferred Evaluation Method:

Perform

__X__

Simulate

References:

PO-3, Alternate Incore and Excore Applications Validation Time: 12 minutes Time Critical:

NO Candidate: ________________________________________________

Time Start: ________

Time Finish:

Performance Time:

________ minutes Performance Rating:

SAT______

UNSAT ______

Comments:

Examiner: _______________________________

Date:

Signature

JPM RO SRO ADMIN 1a PALISADES NUCLEAR PLANT Page 3 of 9 July 2008 EXAMINER COPY ONLY Tools/Equipment/Procedures Needed:

PO-3, Attachment 2, Rev. 2 Also see Simulator Operator Instructions (last page of this document).

READ TO CANDIDATE DIRECTION TO CANDIDATE:

I will explain the initial conditions, and state the task to be performed. All control room steps shall be performed for this JPM, including any required communications. I will provide initiating cues and reports on other actions when directed by you. Ensure you indicate to me when you understand your assigned task. To indicate that you have completed your assigned task return the handout sheet I provided you.

INITIAL CONDITIONS:

  • Plant was at full power.
  • CRD #11 has dropped into the core.

INITIATING CUES:

  • During performance of PO-3, Alternate Incore and Excore Applications, the Control Room Supervisor directs you to calculate Excore Quadrant Power Tilt utilizing Power Range NI Channels on Panel C-06.

JPM RO SRO ADMIN 1a PALISADES NUCLEAR PLANT Page 4 of 9 July 2008 Proc. Step TASK ELEMENT 1 STANDARD Grade n/a Correct Procedure located PO-3, Attachment 2, Excore Quadrant Power Tilt, located.

S U Comment:

Notes:

Evaluator provides candidate with a Working Copy.

Proc. Step TASK ELEMENT 2 STANDARD Grade 5.2.1 Obtain lower and upper excore readings as required. (SAL, SBL, SCL, SDL and SAU, SBU, SCU, SDU).

Lower and upper excore readings from the PPC using NI5L, NI5U, NI6L, NI6U, NI7L, NI7U, NI8L and NI8U or from the Upper and Lower NI Detector meters on EC-06 are entered on PO-3,, within +/-1% (0.01) of the answer key.

S U Comment:

CRITICAL STEP Proc. Step TASK ELEMENT 3 STANDARD Grade 5.2.1 Calculate the sum from the Lower + Upper excore readings (SA, SB, SC, SD Lower + Upper excore readings (SA, SB, SC, SD) summed and entered on PO-3, Attachment #2, within +/-1% (0.01) of the answer key.

S U Comment:

CRITICAL STEP

JPM RO SRO ADMIN 1a PALISADES NUCLEAR PLANT Page 5 of 9 July 2008 Proc. Step TASK ELEMENT 4 STANDARD Grade 5.2.1

1. Calculate the sum of all excore readings divided by 4:

(S = all detectors/4).

Sum of all excores reading divided by 4 calculated and entered on PO-3, Attachment 2, within +/- 1% (0.01) of the answer key.

S U Comment:

CRITICAL STEP Proc. Step TASK ELEMENT 5 STANDARD Grade 5.2.1 Calculate the Quadrant Tilt.

Using the formula TEX

= [(SX - S)/S], calculate the tilt for each Quadrant, within +/-1% (0.01) of the answer key.

S U Comment:

Evaluator: Acceptance criteria is all four Quadrant Tilts should add up to zero (0) +/- 0.01 CRITICAL STEP Proc. Step TASK ELEMENT 6 STANDARD Grade 5.2.1 Have calculations verified.

Have another qualified individual verify the calculations.

S U Comment:

Notes: Evaluator CUE: State to operator that someone else will verify the calculation.

JPM RO SRO ADMIN 1a PALISADES NUCLEAR PLANT Page 6 of 9 July 2008 Proc. Step TASK ELEMENT 7 STANDARD Grade n/a Notify the CRS that Excore Quadrant Power Tilt has been completed per PO-3,.

Operator notifies CRS of completion of PO-3,, Excore Quadrant Power Tilt S U Comment:

END OF TASK

JPM RO SRO ADMIN 1a PALISADES NUCLEAR PLANT Page 7 of 9 July 2008 CANDIDATE CUE SHEET (TO BE RETURNED TO EXAMINER TO UPON COMPLETION OF TASK)

INITIAL CONDITIONS:

  • Plant was at full power.
  • CRD #11 has dropped into the core.

INITIATING CUES:

  • During performance of PO-3, Alternate Incore and Excore Applications, the Control Room Supervisor directs you to calculate Excore Quadrant Power Tilt utilizing Power Range NI Channels on Panel C-06.

JPM RO SRO ADMIN 1a PALISADES NUCLEAR PLANT Page 8 of 9 July 2008 SIMULATOR OPERATOR INSTRUCTIONS SIMULATOR SET UP:

Simulator Setup Instructions:

  • Full power IC
  • Drop CRD #11 fully into the core with RD-11 (Final Value = 2) on PIDRD02
  • When plant has stabilized, freeze the Simulator and SNAP. ***See NOTE #1 below.
  • Use PO-3, Attachment 2 and record/calculate from the Upper and Lower NI Detector meters on EC-06) and use as answer key.
  • Leave the Simulator in freeze during performance of this JPM to ensure that the conditions will not change

JPM RO SRO ADMIN 1a PALISADES NUCLEAR PLANT Page 9 of 9 July 2008 Excore Lower Reading(%)

SAL, SBL, SCL, SDL Upper Reading(%)

SAU, SBU, SCU, SDU Lower + Upper SA, SB, SC, SD S = ( All Detectors)/4

= (SA + SB + SC + SD)/4 Excore Quadrant Tilt TEA, TEB, TEC, TED 5 (CH A)

SAL =

50.5 SAU =

50 SA = SAL + SAU 100.5 95.125 TEA = [(SA-S)/S]

.0565 QUAD 1 6 (CH B)

SBL =

40 SBU =

39 SB = SBL + SBU 79 TEB = [(SB-S)/S]

-.1695 QUAD 3 7 (CH C)

SCL =

50 SCU =

50 SC = SCL + SCU 100 TEC = [(SC-S)/S]

.0512 QUAD 4 8 (CH D)

SDL =

52 SDU =

49 SD = SDL + SDU 101 TED = [(SD-S)/S]

.0618 QUAD 2 NOTE:

The four QPTs should sum to approximately zero.

Comments:

Performed By: ____Pat Person_________________________________

Date: _____Today__________ Time: _______Now______

Calculations Verified By: _____________________________________________________

Date: _______________

After calculations are verified, forward to Reactor Engineering Supervisor or designee for final review.

Reactor Engineering Supervisor or designee: _______________________________________

Date: _______________

ANSWER KEY ANSWER KEY ANSWER KEY ANSWER KEY ANSWER KEY ANSWER KEY