ENS 44492: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 09/16/2008 07:34 EDT
| event date = 09/16/2008 07:34 EDT
| last update date = 09/16/2008
| last update date = 09/16/2008
| title = Loss Of Shutdown Cooling Capability
| title = Loss of Shutdown Cooling Capability
| event text = On September 16, 2008 at 0734 the James A, FitzPatrick Nuclear Power Plant was shutdown and operating in the refueling mode (Mode 5), when shutdown cooling was lost. Shutdown cooling was lost while hanging a tagout on the Reactor Protection System (RPS). When removing fuses as directed by the tagout, isolation logic for Shutdown Cooling suction salve 10MOV-18 was actuated. This Suction Valve isolates the common shutdown cooling suction line to all Residual Heat Removal (RHR) Pumps. At the time of the isolation cavity flood-up was in progress and the time to boil was greater than 5.5 hours. The appropriate Technical Specification LCO Actions were entered and shutdown cooling was restored at 08:27.
| event text = On September 16, 2008 at 0734 the James A, FitzPatrick Nuclear Power Plant was shutdown and operating in the refueling mode (Mode 5), when shutdown cooling was lost. Shutdown cooling was lost while hanging a tagout on the Reactor Protection System (RPS). When removing fuses as directed by the tagout, isolation logic for Shutdown Cooling suction salve 10MOV-18 was actuated. This Suction Valve isolates the common shutdown cooling suction line to all Residual Heat Removal (RHR) Pumps. At the time of the isolation cavity flood-up was in progress and the time to boil was greater than 5.5 hours. The appropriate Technical Specification LCO Actions were entered and shutdown cooling was restored at 08:27.
Power was restored to RPS and work in that system has been suspended pending the results our investigation into the cause of the event.  Also additional controls have been established to review any electrical jumper/ protective tagging interactions prior to installation.
Power was restored to RPS and work in that system has been suspended pending the results our investigation into the cause of the event.  Also additional controls have been established to review any electrical jumper/ protective tagging interactions prior to installation.

Latest revision as of 21:13, 1 March 2018

ENS 44492 +/-
Where
Fitzpatrick Constellation icon.png
New York (NRC Region 1)
Reporting
10 CFR 50.72(b)(3)(v)(B), Loss of Safety Function - Remove Residual Heat
LER: 05000333/LER-2008-001
Time - Person (Reporting Time:+1.58 h0.0658 days <br />0.0094 weeks <br />0.00216 months <br />)
Opened: Eugene Dorman
13:09 Sep 16, 2008
NRC Officer: Jason Kozal
Last Updated: Sep 16, 2008
44492 - NRC Website
Loading map...