| title = Agreement State - Source Unable | | title = Agreement State - Source Unable to Be Retrieved Into Shielded Device | ||
| event text = The following report was received from the Louisiana Department of Environmental Quality via email: | | event text = The following report was received from the Louisiana Department of Environmental Quality via email: | ||
[On] 05/15/2017, [at] 11:50 [CDT], the Radiation Safety Officer of Team Industrial Services, Inc. called the Radiation Section of LDEQ [Louisiana Department of Environmental Quality] to report a source retrieval that occurred on 05/14/2017 [at approximately] 18:00 [CDT] at the INDORAMA VENTURES OLEFINS Refinery is Sulphur, LA at 4300 Hwy 108, Westlake, LA 70669. The camera was being used on a gridded walkway to radiograph some construction material situated on a tripod. The tripod became unstable causing the material to fall and crimp the guide tube. The source was in the collimator and was unable to be retrieved into the shielded exposure device. A retrieval crew was assembled and they were able to retrieve the source and return it to the shielded position. Two radiographers and a site RSO [Radiation Safety Officer] conducted the retrieval activities. The retrieval process was safely completed at [approximately] 20:30 [CDT] on 05/14/2017. | [On] 05/15/2017, [at] 11:50 [CDT], the Radiation Safety Officer of Team Industrial Services, Inc. called the Radiation Section of LDEQ [Louisiana Department of Environmental Quality] to report a source retrieval that occurred on 05/14/2017 [at approximately] 18:00 [CDT] at the INDORAMA VENTURES OLEFINS Refinery is Sulphur, LA at 4300 Hwy 108, Westlake, LA 70669. The camera was being used on a gridded walkway to radiograph some construction material situated on a tripod. The tripod became unstable causing the material to fall and crimp the guide tube. The source was in the collimator and was unable to be retrieved into the shielded exposure device. A retrieval crew was assembled and they were able to retrieve the source and return it to the shielded position. Two radiographers and a site RSO [Radiation Safety Officer] conducted the retrieval activities. The retrieval process was safely completed at [approximately] 20:30 [CDT] on 05/14/2017. |
Revision as of 21:42, 1 March 2018
Where | |
---|---|
Team Industrial Services, Inc Gonzales, Louisiana (NRC Region 4) | |
License number: | La-9098-L01 |
Organization: | Louisiana Radiation Protection Div |
Reporting | |
Agreement State | |
Time - Person (Reporting Time:+0.57 h0.0238 days <br />0.00339 weeks <br />7.80786e-4 months <br />) | |
Opened: | Joseph Noble 17:24 May 15, 2017 |
NRC Officer: | Jeff Herrera |
Last Updated: | May 15, 2017 |
52755 - NRC Website | |