| number = ML19208B199 | | number = ML19208B199 | ||
| issue date = 09/11/1979 | | issue date = 09/11/1979 | ||
| title = | | title = First Interim Deficiency Rept Re Ice Condenser Heat Loads Exceeding Design Heat Loads.Could Cause Degradation of Ice in Ice Condenser & Invalidate Safety Analyses.Reasons for Necessity to Operate Four Glycol Chillers Being Studied | ||
| author name = | | author name = | ||
| author affiliation = TENNESSEE VALLEY AUTHORITY | | author affiliation = TENNESSEE VALLEY AUTHORITY |
Latest revision as of 07:22, 24 January 2020
Date released: 08/10/2019 | Download: ML19208B194 |
---|---|
ML19208B199 | |
Person / Time | |
---|---|
Site: | Sequoyah |
Issue date: | 09/11/1979 |
From: | TENNESSEE VALLEY AUTHORITY |
To: | |
References | |
Download: ML19208B199 (1) | |
ML19208B193 | |
Person / Time | |
---|---|
Site: | Sequoyah |
Issue date: | 09/11/1979 |
From: | Mills L TENNESSEE VALLEY AUTHORITY |
To: | OREILLY J P NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II) |
References | |