ML18046B053: Difference between revisions

From kanterella
Jump to navigation Jump to search
Created page by program invented by StriderTol
Created page by program invented by StriderTol
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:r ,-1\ ., ' .\ ' . -consumers Power company General Offices: 1945 W..;.t Parnall Road, Jackson, Ml 49201 * (517) 788-1636 November 12, 1981 Director, Nuclear Reactor Regulation Att Mr Dennis M Crutchfield, Chief Operating Reactors Branch No 5 US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 -LICENSE DPR-20 I i David P Hoffman Nuclear Lic_ensing Administrator PALISADES PLANT PROPOSED TECHNICAL SPECIFICATIONS CHANGE REQUEST -NUREG-0737 ACTION ITEM III. D.1.1 Attached are three (3) originals and thirty seven (37) conformed copies of . a Request for Change to the Palisades Technical Specifications.
{{#Wiki_filter:r ,-1\
The requested i change provides specifications to reduce leakage from systems outside that would or could contain highly radioactive fluids during a serious transient or accident to as-low-as-practical levels in accordance with the requirements of NUREG-0737, Item III.D.1.1.
I
The proposed change involves a single safety issue, therefore, a check in the amount of $4,000.00 is attached pursuant to 10 CFR 170.22, Class III change. David P Hoffman Nuclear Licensing CC Director, Region III, USNRC NRC Resident Inspector-Palisades ( 81t1170290 011112':"'.
~~ ' .\ \~
I PDR ADOCK 0500025,5*
          ' .     -                                                                                                             i consumers Power                                                     David P Hoffman company                                                   Nuclear Lic_ensing Administrator General Offices: 1945 W..;.t Parnall Road, Jackson, Ml 49201 * (517) 788-1636 November 12, 1981 Director, Nuclear Reactor Regulation Att Mr Dennis M Crutchfield, Chief Operating Reactors Branch No 5 US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 - LICENSE DPR-20 PALISADES PLANT             PROPOSED TECHNICAL SPECIFICATIONS CHANGE REQUEST -
P PDR}}
NUREG-0737 ACTION ITEM III. D.1.1 Attached are three (3) originals and thirty seven (37) conformed copies of
              . a Request for Change to the Palisades Technical Specifications. The requested                                 i change provides specifications to reduce leakage from systems outside containment~
that would or could contain highly radioactive fluids during a serious transient or accident to as-low-as-practical levels in accordance with the requirements of NUREG-0737, Item III.D.1.1.
The proposed change involves a single safety issue, therefore, a check in the amount of $4,000.00 is attached pursuant to 10 CFR 170.22, Class III change.
David P Hoffman Nuclear Licensing           Administrate~
CC   Director, Region III, USNRC NRC Resident Inspector-Palisades
( 81t1170290 011112':"'.
I PDR P
ADOCK 0500025,5*
PDR}}

Revision as of 20:26, 21 October 2019

Forwards Request for Change to Tech Specs to Reduce Leakage from Sys Outside Containment That Could Contain Highly Radioactive Fluids During Serious Accident
ML18046B053
Person / Time
Site: Palisades 
Issue date: 11/12/1981
From: Hoffman D
CONSUMERS ENERGY CO. (FORMERLY CONSUMERS POWER CO.)
To: Crutchfield D
Office of Nuclear Reactor Regulation
Shared Package
ML18046B054 List:
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-3.D.1.1, TASK-TM NUDOCS 8111170290
Download: ML18046B053 (1)


Text

r ,-1\

I

~~ ' .\ \~

' . - i consumers Power David P Hoffman company Nuclear Lic_ensing Administrator General Offices: 1945 W..;.t Parnall Road, Jackson, Ml 49201 * (517) 788-1636 November 12, 1981 Director, Nuclear Reactor Regulation Att Mr Dennis M Crutchfield, Chief Operating Reactors Branch No 5 US Nuclear Regulatory Commission Washington, DC 20555 DOCKET 50-255 - LICENSE DPR-20 PALISADES PLANT PROPOSED TECHNICAL SPECIFICATIONS CHANGE REQUEST -

NUREG-0737 ACTION ITEM III. D.1.1 Attached are three (3) originals and thirty seven (37) conformed copies of

. a Request for Change to the Palisades Technical Specifications. The requested i change provides specifications to reduce leakage from systems outside containment~

that would or could contain highly radioactive fluids during a serious transient or accident to as-low-as-practical levels in accordance with the requirements of NUREG-0737, Item III.D.1.1.

The proposed change involves a single safety issue, therefore, a check in the amount of $4,000.00 is attached pursuant to 10 CFR 170.22, Class III change.

David P Hoffman Nuclear Licensing Administrate~

CC Director, Region III, USNRC NRC Resident Inspector-Palisades

( 81t1170290 011112':"'.

I PDR P

ADOCK 0500025,5*

PDR