{{#Wiki_filter:}} | {{#Wiki_filter:253<Date Entered: Apr 26, 2000 TO: TRANSMITAL NU B R 1433 PROCEDURE NUMBER: EI-4.2 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION TRANSMITTAL: | ||
LISTED BELOW ARE NEW/REVISED PROCEDURES WHICH MUST BE IMMEDIATELY INSERTED INTO OR DISCARDED FROM YOUR PROCEDURE MANUAL. Action Required Section or Description REMOVE AND DESTROY EI-4.2, R/14, ENTIRE PROCEDURE REPLACE WITH EI-4.2, R/14, ENTIRE PROCEDURE EDITORIAL SIGN, DATE, AND RETURN THE ACKNOWLEDGEMENT FORM WITHIN 10 DAYS TO THE PALISADES PLANT DOCUMENT CONTROL.SIGNATURE OR INITIALS DATE Procedure No EI-4.2 Revision 1.4 Issued Date 4/26/00 PALISADES NUCLEAR PLANT EMERGENCY IMPLEMENTING PROCEDURE TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION Protedure Sponsor i4 D-te NKBrott / 4/2/98 Technical Reviewer Date DAWatkins | |||
/ 4/6/98 Qa,,,ýv Date User Reviewer PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page i TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION Table of Contents PERSONNEL RESPONSIBILITY | |||
....................... | |||
1.1 OPERATIONAL SUPPORT CENTER (OSC) DIRECTOR PU RPO SE ..................................... | |||
REFERENCES | |||
,................................... | |||
3.1 SOURCE DOCUMENTS | |||
..................... | |||
3.2 REFERENCE DOCUMENTS | |||
................... | |||
INITIAL CONDITIONS AND/OR REQUIREMENTS | |||
.......... | |||
PROCEDURE | |||
................................... | |||
5.1 FACILITY DESCRIPTION | |||
..................... | |||
5.1.1 Facility Intent ..................... | |||
5.1.2 Physical Location .................. | |||
5.1.3 r ga i t n ...................... | |||
5.1.4 Equipment | |||
....................... | |||
ACTIVATION | |||
................. | |||
5.2.1 Assembly and Accountability 5.2.2 Physical Arrangement | |||
.... OSC PERSONNEL | |||
.............. | |||
5.3.1 OSC Directo .......... | |||
5.3.2 Maintenance Supervisor | |||
... 5.3.3 Health Physics Supervisor 5.3.4 Chemistry Supervisor | |||
..... 5.3.5 OSC/TSC Communicators (M Physics) ............ | |||
Technical Information Facilita Radio Communicator | |||
..... Emergency Maintenance Tear Chemistry Technicians | |||
....5.3.6 5.3.7 5.3.8 5.3.9 aintenance tor (TIF) .. ...=..and Health 1.0 2.0 3.0 4.0 5.0.I .I .I .I .1 .1 .2 .2 .2 .2 .3 .3 *3 .3 .3 .4 .4 .4 .5 *5 .7 .7 *8 .9 .9 10 5.2 5.3 Q 0 PALISADES NUCLEAR PLANT EMERGENCY IMPLEMENTING PROCEDURE Proc No EI-4.2 Revision 14 Page ii TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION Table of Contents 5.3.10 5.3.11 5.3.12 5.3.13 10 11 11 12 EVACUATION/RELOCATION | |||
.......... 13 ATTACHMENTS AND RECORDS ................... | |||
6.1 6.2 ATTACHM ENTS ............................... | |||
REC O RDS ................................... | |||
Attachment Attachment Attachment e IAttachment Attachment Attachment Attachment Attachment Attachment 1, 2, 3, 4, 5, 6, 7, 8, 9,"Operational Support "Operational Support "Operational Support "Operational Support "Operational Support "Operational Support "Operational Support "Operational Support "Sequence of Events Center Activation List" Center Floor Plan" Center Organizational Chart" Center Dosimetry Log Sheet" Center Instrument Control Log Sheet" Center Request Form" Center Response Team Form" Center Response Team Checklist" Form" Attachment 10, "Operational Support Center Priority Form" 5.4 Health Physics Technicians | |||
................. | |||
Dosimetry Support ...................... | |||
Health Physics Support ................... | |||
Auxiliary Operator (AO) ................... | |||
6.0 ATTACHMENTS 13 13 14 I I PALISADES NucLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 1 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 1.0 PERSONNEL RESPONSIBILITY 1.1 OPERATIONAL SUPPORT CENTER (OSC) DIRECTOR The OSC Director is responsible for overall activation and direction of the OSC in support of the Technical Support Center (TSC), Engineering and Maintenance Support Group, Health Physics (HP) Support Group, and Operational Support Group Chemistry Team. 2.0 PURPOSE To provide guidance for efficient activation and operation of the OSC to adequately support the TSC in an emergency. | |||
==3.0 REFERENCES== | |||
3.1 SOURCE DOCUMENTS 3.1.1 NUREG 0654, Section H, "Emergency Facilities and Equipment" 3.1.2 Site Emergency Plan, Section 7, "Emergency Facilities and Equipment" 3.2 REFERENCE DOCUMENTS 3.2.1 Emergency Implementing Procedure El-1 2.1, "Personnel Accountability" 3.2.2 Emergency Implementing Procedure EI-8, "Onsite Radiological Monitoring" 3.2.3 Emergency Implementing Procedure El-1 4, "Medical Care/Treatment of Contaminated, Injured Personnel" 3.2.4 Emergency Implementing Procedure EI-9, "Offsite Radiological Monitoring" USER ALERT INFORMATION USE PROCEDURE The activities covered by this procedure may be performed from memory. | |||
PALISADES NUCLEAR PLANT EMERGENCY IMPLEMENTING PROCEDURE Proc No EI-4.2 Revision 14 Page 2 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 3.2.5 Emergency Implementing Procedure EI-7.0, "Emergency Post Accident Sampling Decision Process" 3.2.6 Emergency Implementing Procedure EI-12.3, "Search and Rescue Team Responsibilities" 3.2.7 Emergency Implementing Procedure El-1 6.1, "Maintenance of Emergency Equipment" 3.2.8 Emergency Implementing Procedure EI-2.1, "Site Emergency Director" 3.2.9 Emergency Implementing Procedure EI-3, "Communications and Notifications" 3.2.10 Radiological Work Practice 316, "Electronic Dosimetry Operations with MIS Down" INITIAL CONDITIONS AND/OR REQUIREMENTS The OSC shall be activated at the Alert or higher emergency classification. | |||
The OSC may be activated before this time at the option of the Site Emergency Director (SED). PROCEDURE 5.1.1 Facility Intent The OSC provides a control point for onsite and initial offsite (prior to EOF activation) support involving Chemistry, HP, Maintenance and Operations. | |||
Reference Emergency Implementing Procedure EI-3, "Communications and Notifications," Attachment 5, "Emergency Response Facilities Phone List," for the complete phone list.4.0 5.0 5.1 USER ALERT INFORMATION USE PROCEDURE The activities covered by this procedure may be performed from memory.FACILITY DESCRIPTION I I I 1, I PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 3 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.1.2 Physical Location The OSC encompasses Assembly Area V (located in the Service Building Lunchroom) and Assembly Area VI (located in the Main Locker Room across from lunchroom). | |||
Attachment 2 provides a floor plan of the OSC. 5.1.3 The OSC consists of personnel outlined in Section 5.3 of this procedure. | |||
Attachment 3 provides a block diagram of OSC organization. | |||
Auxiliary Operators are not included on Attachment 3; see Section 5.3.13 for specifics. | |||
5.1.4 Equipment OSC emergency equipment shall be as described in Emergency Implementing Procedure El-1 6.1, "Maintenance of Emergency Equipment." Additional equipment may be obtained as habitability of an area is ascertained. | |||
5.2 ACTIVATION 5.2.1 Assembly and Accountability | |||
: a. Upon sounding of the emergency siren, or at the direction of the SED, personnel assigned to Assembly Areas V and VI shall proceed to their assembly area and report to their Assembly Area Leader. b. Initial habitability of the OSC should be verified upon assembly. | |||
If the area dose rate exceeds 100 mrem/hr or air concentration is 40 DACs, immediately notify the OSC Director. | |||
: c. Personnel accountability shall be performed per Emergency Implementing Procedure El-12.1, "Personnel Accountability." | |||
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 4 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.2.2 Physical Arrangement | |||
: a. Establish personnel zones per the layout on Attachment 2 of this procedure, or as directed by the OSC Director. | |||
: b. Obtain OSC emergency equipment from the Fan Room located north of the OSC. Distribute equipment and post status boards per the layout in Attachment 2 of this procedure. | |||
: c. Establish a frisking station for equipment and personnel monitoring in a low background area, < 300 cpm, as close to the entrance of the OSC as possible. | |||
: d. Establish a dosimetry control point near the entrance to the OSC. An equipment staging area should be set up in the OSC facility. | |||
: e. Establish a station for sample analysis in accordance with Emergency Implementing Procedure EI-8, "Onsite Radiological Monitoring," Step 5.2.4b, "OSC Activation." 5.3 OSC PERSONNEL 5.3.1 OSC Director The OSC Director shall: a. Ensure accountability is completed within 30 minutes. | |||
: b. Ensure adequate personnel are available for performance of OSC functions. | |||
: c. Direct physical activation and layout of the OSC using Attachments 1 and 2 of this procedure as guidance. | |||
: d. Apprise OSC personnel of Plant conditions and emergency classification throughout the emergency. | |||
: e. Coordinate efficient and orderly function of the OSC. f. Coordinate priorities for HP coverage of maintenance activities with the Health Physics Supervisor(s). | |||
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 5 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION | |||
: g. Ensure all mandatory actions and Plant priorities are communicated to the OSC staff. h. Assume responsibility for Auxiliary Operators (AOs) after the OSC is declared operational and the Shift Supervisor has released them to the OSC. i. Shall ensure prejob briefings are conducted using Attachment 9, "Operational Support Center Emergency Crew Checklist," for all teams leaving the OSC except HP teams that use Emergency Implementing Procedures EI-8, "Onsite Radiological Monitoring," and EI-9, "Offsite Radiological Monitoring." 5.3.2 Maintenance Supervisor The Maintenance staff may include an I&C Supervisor, Electrical Maintenance Supervisor, and a Mechanical Maintenance Supervisor. | |||
Maintenance Supervisors should: a. Assist the OSC Director in accountability and activation of the OSC. b. Organize and direct the appropriate emergency maintenance teams as per the TSC and OSC Director. | |||
: c. Ensure that all emergency maintenance teams report to the HP Supervisor for a prejob briefing. | |||
: d. If needed, direct I&C Technicians to adjust master PA volume potentiometer in the telephone room (3rd floor Administration Building) with SED approval. | |||
5.3.3 Health Physics Supervisor The HP Supervisor shall: a. Assist the OSC Director in accountability, activation, and subsequent functions of the OSC, as needed. b. Ensure HP prejob briefings and debriefing of returning work teams are conducted. | |||
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 6 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION NOTE: Quick dispatch of Search and Rescue Teams is vital in case missing persons need medical assistance. | |||
: c. Organize and direct Search and Rescue teams in accordance with Emergency Implementing Procedure El-1 2.3, "Search and Rescue Team Responsibilities," as directed by the TSC. d. Organize and direct onsite monitoring teams in accordance with Emergency Implementing Procedure EI-8, "Onsite Radiological Monitoring," as directed by the TSC. e. Organize and direct first aid teams in accordance with Emergency Implementing Procedure EI-14, "Medical Care/Treatment of Contaminated, Injured Personnel." If offsite medical assistance is needed in an Alert or above, request through the TSC HP Support Group that the TSC Communicator make the appropriate calls. f. Organize and direct offsite monitoring teams, prior to EOF activation in accordance with Emergency Implementing Procedure EI-9, "Offsite Radiological Monitoring," as directed by the TSC. Upon EOF activation, establish EOF radio contact with the teams and ensure the following information is relayed to HP Support Group (as applicable): | |||
: 1. Number of teams. 2. Team members, identified. | |||
: 3. Team(s) location. | |||
: 4. Pertinent surveys, results. | |||
: 5. Pertinent samples taken, results. | |||
: 6. Team(s) dose records. | |||
: 7. Meteorological data. g. Supervise dosimetry and equipment control. | |||
: h. Perform Dose Limit Assessments (reference Emergency Implementing Procedure EI-2.1, "Site Emergency Director"). | |||
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 7 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION | |||
: i. Provide HP support for Chemistry/Maintenance/Operations teams. j. Ensure HP status boards are updated. | |||
: k. Direct the Security teams on radiologically acceptable routes onsite. 5.3.4 Chemistry Supervisor The Chemistry Supervisor shall: a. Assist the OSC Director in accountability, activation, and subsequent functions of the OSC, as needed. b. Organize and direct the post accident sampling and analysis teams in accordance with Emergency Implementing Procedure EI-7, "Emergency Post Accident Sampling Decision Process," as directed by the TSC. c. Organize and direct onsite analysis of samples on the Multi-Channel Analyzer (MCA); coordinating with the HP Supervisor in prioritizing sample counting. | |||
5.3.5 OSC/TSC Communicators (Maintenance and Health Physics) The Communicators shall: a. Setup and test communications using telephones/sound-powered phone contained in the OSC Emergency Kit. b. Establish communication with TSC counterpart. | |||
: c. Document incoming requests on Attachment 7, as appropriate. | |||
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 8 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION | |||
: d. The OSC/TSC Maintenance Communicator should: 1. Maintain the OSC status board which lists emergency priorities and equipment out of service. | |||
: 2. Periodically validate that the emergency priorities listed in the TSC and OSC are in agreement. | |||
: 3. Advise TSC Eng/Maintenance of available maintenance resources from the OSC Resources status board. e. The OSC/TSC Health Physics Communicator should: 1. Obtain meteorological data from the TSC. 2. Maintain offsite and onsite team information. | |||
: 3. Advise TSC HP of changes made in the OSC Response Team status board. 4. Advise TSC HP of available OSC HP resources from the OSC Resources status board. 5.3.6 Technical Information Facilitator (TIF) a. Maintain the Sequence of Events board for the Operational Support Center (OSC), and use Attachment 10, as needed. b. Remain on the dedicated group line until relieved by another qualified individual. | |||
: c. Assist the OSC Director in maintaining communications with the TSC, Control Room, and EOF. d. Assist the OSC Director with dispatching AOs from the OSC. e. Discuss OSC priorities with the other facility TIFs and notify OSC leadership of impending conflicts. | |||
: f. Notify OSC leadership of important and/or emergency developments. | |||
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 9 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.3.7 Radio Communicator The Radio Communicator shall: a. Setup and test radio communications, using hand-held battery powered radios and mobile radios contained in the OSC Emergency Kit. b. Relay messages to and from the onsite and offsite monitoring teams via hand-held/mobile radio, or other available means. Upon EOF activation, assist the EOF Radio Communicator in turnover of the offsite monitoring teams to the EOF HP Support Team. c. Ensure efficient and timely information flow and documentation of messages by documenting incoming information from onsite/offsite teams for OSC HP Supervisor review and disposition. | |||
: d. Ensure the 10-mile EPZ map is updated with radiological data from Offsite Monitoring Teams. 5.3.8 Emergency Maintenance Teams Emergency Maintenance Teams should: a. Attend prejob briefing(s) prior to performing emergency maintenance. | |||
: b. Perform permanent or temporary emergency repairs as directed by the OSC Maintenance Supervisors. | |||
: c. Report back to HP Supervisor on return to OSC for debriefing. | |||
: d. Follow guidelines of crew checklist (Attachment | |||
: 9) for implementation and task completion. | |||
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 10 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.3.9 Chemistry Technicians Chemistry Technicians shall: a. Assist in initial physical arrangement of the OSC facility per Section 5.2.2 of this procedure. | |||
: b. Perform post accident sampling and analysis in accordance with Emergency Implementing Procedure EI-7, "Emergency Post Accident Sampling Decision Process." c. Perform onsite analysis of samples on the Multi-Channel Analyzer (MCA). 5.3.10 Health Physics Technicians HP Technicians shall: a. Transport available survey instruments, air samplers, and other appropriate equipment to the OSC. b. Assist in physical activation and equipment setup of the OSC per Attachment | |||
: 1. c. Perform onsite monitoring in accordance with Emergency Implementing Procedure EI-8, "Onsite Radiological Monitoring." d. Perform offsite monitoring in accordance with Emergency Implementing Procedure EI-9, "Offsite Radiological Monitoring." e. Perform search and rescue, first aid in accordance with Emergency Implementing Procedures El-1 2.3, "Search and Rescue Team Responsibilities," and EI-14, "Medical Care/Treatment of Contaminated, Injured Personnel." f. Upon return to the OSC, ensure that status boards, OSC-4, "Monitoring Team Data," and OSC-6, "Onsite Monitoring Board (Habitability Areas)," are updated. | |||
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 11 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.3.11 Dosimetry Support Dosimetry Support personnel shall: a. Set up and bring equipment designated in Sections 2c and g, Attachment 1, of this procedure. | |||
Controlled procedures and copies of appropriate attachments are located in the OSC Emergency Kit. b. Assist in initial physical arrangement of the OSC facility per Section 5.2.2 of this procedure. | |||
: c. Maintain dosimetry and equipment control throughout the emergency, utilizing Attachments 4 and 5 as appropriate. | |||
: d. Dose tracking will normally be completed by logging in and out on MIS during an emergency. | |||
Attachment 4 may be used to provide additional documentation, as determined appropriate by the Health Physics Supervisor. | |||
: e. Attachment 4 shall be maintained for each person manually if MIS is down or not available at the assembly area. Electronic Dosimeters (ED) can be used when MIS is down by using Radiological Work Practice 316, "Electronic Dosimetry Operations With MIS Down," instructions on how to operate on ED reader without MIS. 5.3.12 Health Physics Support HP Support shall: a. Assist in initial physical arrangement of the OSC facility per Section 5.2.2 of this procedure. | |||
: b. Keep the status boards updated as information becomes available. | |||
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 12 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION I 5.3.1 3 Auxiliary Operator (AO) a. Report to the Control Room for accountability when the emergency siren is sounded. If an AO is carrying out an assignment thought to be critical, the AO should contact the Control Room for permission to continue. | |||
: b. AOs will be dispatched from the Control Room until the OSC is declared operational. | |||
: c. AOs dispatched from the Control Room should: 1. Proceed to Access Control and obtain an electronic dosimeter. | |||
: 2. Log onto the pre-existing emergency RWP which will be a 6 digit "Year #-9999," ie, 96-9999. | |||
: 3. Enter the RCA and obtain a dose rate meter. 4. Perform assignment. | |||
: 5. Update the Control Room Supervisor (CRS) frequently. | |||
: 6. Notify CRS when assignment is completed. | |||
: 7. If the OSC is NOT operational, an AO can be given another assignment or told to report back to the Control Room. 8. If the OSC has been declared operational, an AO should report to the OSC Director. | |||
: d. AOs being dispatched from the OSC should: 1. Ensure their name is placed on the OSC Resources status board. 2. Sign on the emergency RWP if not already done. 3. Obtain an electronic dosimeter if not already done. | |||
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 13 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.4 EVACUATION/RELOCATION If the area dose rate exceeds 100 mrem/hr or air concentration is 40 DACs, the OSC shall relocate to the Mechanical Maintenance Shop or the SED shall designate an alternate location. | |||
Evacuation shall be performed with the concurrence of the SED unless the delay caused by waiting for concurrence would endanger OSC personnel. | |||
The evacuation should be announced over the public address system. If the Mechanical Maintenance Shop is not habitable, the SED shall designate an alternate OSC location. | |||
Equipment relocated upon evacuation shall be designated by the SED (or alternate) per Attachments 1 through 4 of Emergency Implementing Procedure El-1 6.1, "Maintenance of Emergency Equipment" (as appropriate). | |||
6.0 ATTACHMENTS AND RECORDS 6.1 ATTACHMENTS 6.1.1 Attachment 1, "Operational Support Center Activation List" Attachment Attachment Attachment Attachment Sheet" Attachment Attachment Attachment Attachment Attachment 2, 3, 4, 5,"Operational "Operational "Operational "Operational Support Support Support Support Center Center Center Center Floor Plan" Organizational Chart" Dosimetry Log Sheet" Instrument Control Log 6, "Operational Support Center Request Form" 7, "Operational Support Center Response Team Form" 8, "Operational Support Center Response Team Checklist" 9, "Sequence of Events Form" 10, "Operational Support Center Priority Form" 6.1.2 6.1.3 6.1.4 6.1.5 6.1.6 6.1.7 6.1.8 6.1.9 6.1.10 PALISADES NUCLEAR PLANT EMERGENCY IMPLEMENTING PROCEDURE Proc No EI-4.2 Revision 14 Page 14 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION RECORDS Records generated by this procedure shall be filed in accordance with Palisades Administrative Procedure 10.46, "Plant Records." Refer to the record matrix attached to AP 10.46 for information needed to complete Record Indexing Form (Form 104).6.2 I Proc No EI-4.2 Attachment 1 Revision 14 Page 1 of 1 OPERATIONAL SUPPORT CENTER ACTIVATION LIST SECTION 1: ASSEMBLY AND ACCOUNTABILITY | |||
: a. OSC habitable? | |||
Yes_ No_ Classification Time b. Accountability completed. | |||
Time c. Announce Key Players/Positions to OSC personnel. | |||
Time d. Emergency Classification sign posted. e. Command and Control sign posted. SECTION 2: PHYSICAL ARRANGEMENT | |||
: a. Layout per Attachment | |||
: 2. b. Frisking station established. | |||
: c. Dosimetry/Equipment control point established, rad controlled area, dosimetry records (Attachments 4, 5, and 6). d. Status boards in place. e. Sample station established. | |||
: f. Communications with TSC and associated phone lines completed. | |||
: g. Emergency MIS Computer. | |||
OPERATIONAL SUPPORT CENTER FLOOR PLAN Proc No EI-4.2 Attachment 2 Revision 14 Page 1 of 1 vialn Lockaroom Aoesably Ae.o VI mainteanc. | |||
Personnel OSC BOARDS OSC-1 -OSC Resources OSC-2 -Emergency Onsite El Monitoring Map OSC-3 -Response Teams OSC-4 -Monitoring Team Data** OSC-5 -OSC Priorities Board OSC-6 -Onsite Monitoring Board (Habitability Areas) | |||
* OSC-7 Mile EPZ Map** OSC-8 -Sequence of Events Board OSC EMERGENCY KIT C c SA MIS COMPUTER CARTS "; G ARE STORED INSIDE CAGE FAN ROOM I .:. .Z OSC-5 04 oSc #1 If OSC $3 o9C #2 0 '1. 0 0 0 Lunch Room Assoembly Area V*OSC Phones -X 2596 (Chem) -x 2409 (HP) -X 2410 (HP Communicator) -X 2346 (General) -Direct Line to TSC -X 2109 OSC Director -X 2110 TIP -X 764-2730 (FAX) -X 2243 (Maint. Communicator) -OSC to Met Tower Line (HP Radio) -764-9994 Phone Jack under wall phone X2346 These boards are stored in the cage in the Fan Room behind OSC. | |||
OPERATIONAL SUPPORT CENTER ORGANIZATIONAL CHART Proc No EI-4.2 Attachment 3 Revision 14 Page 1 of 1-w/Offslte Teams w/TSC HP*The OSC Director is responsible for maintaining accountability of AOs after the OSC is declared operational and the Shift Supervisor has released them to the OSC. | |||
OPERATIONAL SUPPORT CENTER DOSIMETRY LOG SHEET Proc No EI-4.2 Attachment 4 Revision 14 Page 1 of 1 SSN Department Available Dose Total Dose Received Data Entered into MIS Name Time Out ED Reading Time ED Reading Dose Available Returned Received Dose Time Out ED Reading Time ED Reading Dose Available Returned Received Dose OPERATIONAL SUPPORT CENTER INSTRUMENT CONTROL LOG SHEET Proc No EI-4.2 Attachment 5 Revision 14 Page 1 of 1 Date: Name Instrument Consumers Location Time Contam Operation Instrument Type Energy # I Tagged OOS Out In Out !In OutJ In t I 4. 4 I + I + I +I -t 4 .4 4- * + 4 4 4. 4- 4. 4 4- 1 4- 4.7 1 I 4. 1 I 4 4 4 4- 4 1 1. 1 4. 1 1}} |
Revision as of 18:51, 17 July 2019
ML003710938 | |
Person / Time | |
---|---|
Site: | Palisades |
Issue date: | 04/26/2000 |
From: | Brott N, Watkins D Consumers Energy |
To: | Mcknight J Document Control Desk, Office of Nuclear Security and Incident Response |
References | |
-RFPFR El-4.2, Revision 14 | |
Download: ML003710938 (23) | |
Text
253<Date Entered: Apr 26, 2000 TO: TRANSMITAL NU B R 1433 PROCEDURE NUMBER: EI-4.2 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION TRANSMITTAL:
LISTED BELOW ARE NEW/REVISED PROCEDURES WHICH MUST BE IMMEDIATELY INSERTED INTO OR DISCARDED FROM YOUR PROCEDURE MANUAL. Action Required Section or Description REMOVE AND DESTROY EI-4.2, R/14, ENTIRE PROCEDURE REPLACE WITH EI-4.2, R/14, ENTIRE PROCEDURE EDITORIAL SIGN, DATE, AND RETURN THE ACKNOWLEDGEMENT FORM WITHIN 10 DAYS TO THE PALISADES PLANT DOCUMENT CONTROL.SIGNATURE OR INITIALS DATE Procedure No EI-4.2 Revision 1.4 Issued Date 4/26/00 PALISADES NUCLEAR PLANT EMERGENCY IMPLEMENTING PROCEDURE TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION Protedure Sponsor i4 D-te NKBrott / 4/2/98 Technical Reviewer Date DAWatkins
/ 4/6/98 Qa,,,ýv Date User Reviewer PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page i TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION Table of Contents PERSONNEL RESPONSIBILITY
.......................
1.1 OPERATIONAL SUPPORT CENTER (OSC) DIRECTOR PU RPO SE .....................................
REFERENCES
,...................................
3.1 SOURCE DOCUMENTS
.....................
3.2 REFERENCE DOCUMENTS
...................
INITIAL CONDITIONS AND/OR REQUIREMENTS
..........
PROCEDURE
...................................
5.1 FACILITY DESCRIPTION
.....................
5.1.1 Facility Intent .....................
5.1.2 Physical Location ..................
5.1.3 r ga i t n ......................
5.1.4 Equipment
.......................
ACTIVATION
.................
5.2.1 Assembly and Accountability 5.2.2 Physical Arrangement
.... OSC PERSONNEL
..............
5.3.1 OSC Directo ..........
5.3.2 Maintenance Supervisor
... 5.3.3 Health Physics Supervisor 5.3.4 Chemistry Supervisor
..... 5.3.5 OSC/TSC Communicators (M Physics) ............
Technical Information Facilita Radio Communicator
..... Emergency Maintenance Tear Chemistry Technicians
....5.3.6 5.3.7 5.3.8 5.3.9 aintenance tor (TIF) .. ...=..and Health 1.0 2.0 3.0 4.0 5.0.I .I .I .I .1 .1 .2 .2 .2 .2 .3 .3 *3 .3 .3 .4 .4 .4 .5 *5 .7 .7 *8 .9 .9 10 5.2 5.3 Q 0 PALISADES NUCLEAR PLANT EMERGENCY IMPLEMENTING PROCEDURE Proc No EI-4.2 Revision 14 Page ii TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION Table of Contents 5.3.10 5.3.11 5.3.12 5.3.13 10 11 11 12 EVACUATION/RELOCATION
.......... 13 ATTACHMENTS AND RECORDS ...................
6.1 6.2 ATTACHM ENTS ...............................
REC O RDS ...................................
Attachment Attachment Attachment e IAttachment Attachment Attachment Attachment Attachment Attachment 1, 2, 3, 4, 5, 6, 7, 8, 9,"Operational Support "Operational Support "Operational Support "Operational Support "Operational Support "Operational Support "Operational Support "Operational Support "Sequence of Events Center Activation List" Center Floor Plan" Center Organizational Chart" Center Dosimetry Log Sheet" Center Instrument Control Log Sheet" Center Request Form" Center Response Team Form" Center Response Team Checklist" Form" Attachment 10, "Operational Support Center Priority Form" 5.4 Health Physics Technicians
.................
Dosimetry Support ......................
Health Physics Support ...................
Auxiliary Operator (AO) ...................
6.0 ATTACHMENTS 13 13 14 I I PALISADES NucLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 1 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 1.0 PERSONNEL RESPONSIBILITY 1.1 OPERATIONAL SUPPORT CENTER (OSC) DIRECTOR The OSC Director is responsible for overall activation and direction of the OSC in support of the Technical Support Center (TSC), Engineering and Maintenance Support Group, Health Physics (HP) Support Group, and Operational Support Group Chemistry Team. 2.0 PURPOSE To provide guidance for efficient activation and operation of the OSC to adequately support the TSC in an emergency.
3.0 REFERENCES
3.1 SOURCE DOCUMENTS 3.1.1 NUREG 0654, Section H, "Emergency Facilities and Equipment" 3.1.2 Site Emergency Plan, Section 7, "Emergency Facilities and Equipment" 3.2 REFERENCE DOCUMENTS 3.2.1 Emergency Implementing Procedure El-1 2.1, "Personnel Accountability" 3.2.2 Emergency Implementing Procedure EI-8, "Onsite Radiological Monitoring" 3.2.3 Emergency Implementing Procedure El-1 4, "Medical Care/Treatment of Contaminated, Injured Personnel" 3.2.4 Emergency Implementing Procedure EI-9, "Offsite Radiological Monitoring" USER ALERT INFORMATION USE PROCEDURE The activities covered by this procedure may be performed from memory.
PALISADES NUCLEAR PLANT EMERGENCY IMPLEMENTING PROCEDURE Proc No EI-4.2 Revision 14 Page 2 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 3.2.5 Emergency Implementing Procedure EI-7.0, "Emergency Post Accident Sampling Decision Process" 3.2.6 Emergency Implementing Procedure EI-12.3, "Search and Rescue Team Responsibilities" 3.2.7 Emergency Implementing Procedure El-1 6.1, "Maintenance of Emergency Equipment" 3.2.8 Emergency Implementing Procedure EI-2.1, "Site Emergency Director" 3.2.9 Emergency Implementing Procedure EI-3, "Communications and Notifications" 3.2.10 Radiological Work Practice 316, "Electronic Dosimetry Operations with MIS Down" INITIAL CONDITIONS AND/OR REQUIREMENTS The OSC shall be activated at the Alert or higher emergency classification.
The OSC may be activated before this time at the option of the Site Emergency Director (SED). PROCEDURE 5.1.1 Facility Intent The OSC provides a control point for onsite and initial offsite (prior to EOF activation) support involving Chemistry, HP, Maintenance and Operations.
Reference Emergency Implementing Procedure EI-3, "Communications and Notifications," Attachment 5, "Emergency Response Facilities Phone List," for the complete phone list.4.0 5.0 5.1 USER ALERT INFORMATION USE PROCEDURE The activities covered by this procedure may be performed from memory.FACILITY DESCRIPTION I I I 1, I PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 3 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.1.2 Physical Location The OSC encompasses Assembly Area V (located in the Service Building Lunchroom) and Assembly Area VI (located in the Main Locker Room across from lunchroom).
Attachment 2 provides a floor plan of the OSC. 5.1.3 The OSC consists of personnel outlined in Section 5.3 of this procedure.
Attachment 3 provides a block diagram of OSC organization.
Auxiliary Operators are not included on Attachment 3; see Section 5.3.13 for specifics.
5.1.4 Equipment OSC emergency equipment shall be as described in Emergency Implementing Procedure El-1 6.1, "Maintenance of Emergency Equipment." Additional equipment may be obtained as habitability of an area is ascertained.
5.2 ACTIVATION 5.2.1 Assembly and Accountability
- a. Upon sounding of the emergency siren, or at the direction of the SED, personnel assigned to Assembly Areas V and VI shall proceed to their assembly area and report to their Assembly Area Leader. b. Initial habitability of the OSC should be verified upon assembly.
If the area dose rate exceeds 100 mrem/hr or air concentration is 40 DACs, immediately notify the OSC Director.
- c. Personnel accountability shall be performed per Emergency Implementing Procedure El-12.1, "Personnel Accountability."
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 4 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.2.2 Physical Arrangement
- a. Establish personnel zones per the layout on Attachment 2 of this procedure, or as directed by the OSC Director.
- b. Obtain OSC emergency equipment from the Fan Room located north of the OSC. Distribute equipment and post status boards per the layout in Attachment 2 of this procedure.
- c. Establish a frisking station for equipment and personnel monitoring in a low background area, < 300 cpm, as close to the entrance of the OSC as possible.
- d. Establish a dosimetry control point near the entrance to the OSC. An equipment staging area should be set up in the OSC facility.
- e. Establish a station for sample analysis in accordance with Emergency Implementing Procedure EI-8, "Onsite Radiological Monitoring," Step 5.2.4b, "OSC Activation." 5.3 OSC PERSONNEL 5.3.1 OSC Director The OSC Director shall: a. Ensure accountability is completed within 30 minutes.
- b. Ensure adequate personnel are available for performance of OSC functions.
- c. Direct physical activation and layout of the OSC using Attachments 1 and 2 of this procedure as guidance.
- d. Apprise OSC personnel of Plant conditions and emergency classification throughout the emergency.
- e. Coordinate efficient and orderly function of the OSC. f. Coordinate priorities for HP coverage of maintenance activities with the Health Physics Supervisor(s).
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 5 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION
- g. Ensure all mandatory actions and Plant priorities are communicated to the OSC staff. h. Assume responsibility for Auxiliary Operators (AOs) after the OSC is declared operational and the Shift Supervisor has released them to the OSC. i. Shall ensure prejob briefings are conducted using Attachment 9, "Operational Support Center Emergency Crew Checklist," for all teams leaving the OSC except HP teams that use Emergency Implementing Procedures EI-8, "Onsite Radiological Monitoring," and EI-9, "Offsite Radiological Monitoring." 5.3.2 Maintenance Supervisor The Maintenance staff may include an I&C Supervisor, Electrical Maintenance Supervisor, and a Mechanical Maintenance Supervisor.
Maintenance Supervisors should: a. Assist the OSC Director in accountability and activation of the OSC. b. Organize and direct the appropriate emergency maintenance teams as per the TSC and OSC Director.
- c. Ensure that all emergency maintenance teams report to the HP Supervisor for a prejob briefing.
- d. If needed, direct I&C Technicians to adjust master PA volume potentiometer in the telephone room (3rd floor Administration Building) with SED approval.
5.3.3 Health Physics Supervisor The HP Supervisor shall: a. Assist the OSC Director in accountability, activation, and subsequent functions of the OSC, as needed. b. Ensure HP prejob briefings and debriefing of returning work teams are conducted.
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 6 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION NOTE: Quick dispatch of Search and Rescue Teams is vital in case missing persons need medical assistance.
- c. Organize and direct Search and Rescue teams in accordance with Emergency Implementing Procedure El-1 2.3, "Search and Rescue Team Responsibilities," as directed by the TSC. d. Organize and direct onsite monitoring teams in accordance with Emergency Implementing Procedure EI-8, "Onsite Radiological Monitoring," as directed by the TSC. e. Organize and direct first aid teams in accordance with Emergency Implementing Procedure EI-14, "Medical Care/Treatment of Contaminated, Injured Personnel." If offsite medical assistance is needed in an Alert or above, request through the TSC HP Support Group that the TSC Communicator make the appropriate calls. f. Organize and direct offsite monitoring teams, prior to EOF activation in accordance with Emergency Implementing Procedure EI-9, "Offsite Radiological Monitoring," as directed by the TSC. Upon EOF activation, establish EOF radio contact with the teams and ensure the following information is relayed to HP Support Group (as applicable):
- 1. Number of teams. 2. Team members, identified.
- 3. Team(s) location.
- 4. Pertinent surveys, results.
- 5. Pertinent samples taken, results.
- 6. Team(s) dose records.
- 7. Meteorological data. g. Supervise dosimetry and equipment control.
- h. Perform Dose Limit Assessments (reference Emergency Implementing Procedure EI-2.1, "Site Emergency Director").
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 7 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION
- i. Provide HP support for Chemistry/Maintenance/Operations teams. j. Ensure HP status boards are updated.
- k. Direct the Security teams on radiologically acceptable routes onsite. 5.3.4 Chemistry Supervisor The Chemistry Supervisor shall: a. Assist the OSC Director in accountability, activation, and subsequent functions of the OSC, as needed. b. Organize and direct the post accident sampling and analysis teams in accordance with Emergency Implementing Procedure EI-7, "Emergency Post Accident Sampling Decision Process," as directed by the TSC. c. Organize and direct onsite analysis of samples on the Multi-Channel Analyzer (MCA); coordinating with the HP Supervisor in prioritizing sample counting.
5.3.5 OSC/TSC Communicators (Maintenance and Health Physics) The Communicators shall: a. Setup and test communications using telephones/sound-powered phone contained in the OSC Emergency Kit. b. Establish communication with TSC counterpart.
- c. Document incoming requests on Attachment 7, as appropriate.
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 8 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION
- d. The OSC/TSC Maintenance Communicator should: 1. Maintain the OSC status board which lists emergency priorities and equipment out of service.
- 3. Advise TSC Eng/Maintenance of available maintenance resources from the OSC Resources status board. e. The OSC/TSC Health Physics Communicator should: 1. Obtain meteorological data from the TSC. 2. Maintain offsite and onsite team information.
- 3. Advise TSC HP of changes made in the OSC Response Team status board. 4. Advise TSC HP of available OSC HP resources from the OSC Resources status board. 5.3.6 Technical Information Facilitator (TIF) a. Maintain the Sequence of Events board for the Operational Support Center (OSC), and use Attachment 10, as needed. b. Remain on the dedicated group line until relieved by another qualified individual.
- c. Assist the OSC Director in maintaining communications with the TSC, Control Room, and EOF. d. Assist the OSC Director with dispatching AOs from the OSC. e. Discuss OSC priorities with the other facility TIFs and notify OSC leadership of impending conflicts.
- f. Notify OSC leadership of important and/or emergency developments.
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 9 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.3.7 Radio Communicator The Radio Communicator shall: a. Setup and test radio communications, using hand-held battery powered radios and mobile radios contained in the OSC Emergency Kit. b. Relay messages to and from the onsite and offsite monitoring teams via hand-held/mobile radio, or other available means. Upon EOF activation, assist the EOF Radio Communicator in turnover of the offsite monitoring teams to the EOF HP Support Team. c. Ensure efficient and timely information flow and documentation of messages by documenting incoming information from onsite/offsite teams for OSC HP Supervisor review and disposition.
- d. Ensure the 10-mile EPZ map is updated with radiological data from Offsite Monitoring Teams. 5.3.8 Emergency Maintenance Teams Emergency Maintenance Teams should: a. Attend prejob briefing(s) prior to performing emergency maintenance.
- b. Perform permanent or temporary emergency repairs as directed by the OSC Maintenance Supervisors.
- d. Follow guidelines of crew checklist (Attachment
- 9) for implementation and task completion.
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 10 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.3.9 Chemistry Technicians Chemistry Technicians shall: a. Assist in initial physical arrangement of the OSC facility per Section 5.2.2 of this procedure.
- b. Perform post accident sampling and analysis in accordance with Emergency Implementing Procedure EI-7, "Emergency Post Accident Sampling Decision Process." c. Perform onsite analysis of samples on the Multi-Channel Analyzer (MCA). 5.3.10 Health Physics Technicians HP Technicians shall: a. Transport available survey instruments, air samplers, and other appropriate equipment to the OSC. b. Assist in physical activation and equipment setup of the OSC per Attachment
- 1. c. Perform onsite monitoring in accordance with Emergency Implementing Procedure EI-8, "Onsite Radiological Monitoring." d. Perform offsite monitoring in accordance with Emergency Implementing Procedure EI-9, "Offsite Radiological Monitoring." e. Perform search and rescue, first aid in accordance with Emergency Implementing Procedures El-1 2.3, "Search and Rescue Team Responsibilities," and EI-14, "Medical Care/Treatment of Contaminated, Injured Personnel." f. Upon return to the OSC, ensure that status boards, OSC-4, "Monitoring Team Data," and OSC-6, "Onsite Monitoring Board (Habitability Areas)," are updated.
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 11 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.3.11 Dosimetry Support Dosimetry Support personnel shall: a. Set up and bring equipment designated in Sections 2c and g, Attachment 1, of this procedure.
Controlled procedures and copies of appropriate attachments are located in the OSC Emergency Kit. b. Assist in initial physical arrangement of the OSC facility per Section 5.2.2 of this procedure.
- c. Maintain dosimetry and equipment control throughout the emergency, utilizing Attachments 4 and 5 as appropriate.
- d. Dose tracking will normally be completed by logging in and out on MIS during an emergency.
Attachment 4 may be used to provide additional documentation, as determined appropriate by the Health Physics Supervisor.
- e. Attachment 4 shall be maintained for each person manually if MIS is down or not available at the assembly area. Electronic Dosimeters (ED) can be used when MIS is down by using Radiological Work Practice 316, "Electronic Dosimetry Operations With MIS Down," instructions on how to operate on ED reader without MIS. 5.3.12 Health Physics Support HP Support shall: a. Assist in initial physical arrangement of the OSC facility per Section 5.2.2 of this procedure.
- b. Keep the status boards updated as information becomes available.
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 12 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION I 5.3.1 3 Auxiliary Operator (AO) a. Report to the Control Room for accountability when the emergency siren is sounded. If an AO is carrying out an assignment thought to be critical, the AO should contact the Control Room for permission to continue.
- c. AOs dispatched from the Control Room should: 1. Proceed to Access Control and obtain an electronic dosimeter.
- 2. Log onto the pre-existing emergency RWP which will be a 6 digit "Year #-9999," ie, 96-9999.
- 3. Enter the RCA and obtain a dose rate meter. 4. Perform assignment.
- 5. Update the Control Room Supervisor (CRS) frequently.
- 6. Notify CRS when assignment is completed.
- 7. If the OSC is NOT operational, an AO can be given another assignment or told to report back to the Control Room. 8. If the OSC has been declared operational, an AO should report to the OSC Director.
- d. AOs being dispatched from the OSC should: 1. Ensure their name is placed on the OSC Resources status board. 2. Sign on the emergency RWP if not already done. 3. Obtain an electronic dosimeter if not already done.
PALISADES NUCLEAR PLANT Proc No EI-4.2 EMERGENCY IMPLEMENTING PROCEDURE Revision 14 Page 13 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION 5.4 EVACUATION/RELOCATION If the area dose rate exceeds 100 mrem/hr or air concentration is 40 DACs, the OSC shall relocate to the Mechanical Maintenance Shop or the SED shall designate an alternate location.
Evacuation shall be performed with the concurrence of the SED unless the delay caused by waiting for concurrence would endanger OSC personnel.
The evacuation should be announced over the public address system. If the Mechanical Maintenance Shop is not habitable, the SED shall designate an alternate OSC location.
Equipment relocated upon evacuation shall be designated by the SED (or alternate) per Attachments 1 through 4 of Emergency Implementing Procedure El-1 6.1, "Maintenance of Emergency Equipment" (as appropriate).
6.0 ATTACHMENTS AND RECORDS 6.1 ATTACHMENTS 6.1.1 Attachment 1, "Operational Support Center Activation List" Attachment Attachment Attachment Attachment Sheet" Attachment Attachment Attachment Attachment Attachment 2, 3, 4, 5,"Operational "Operational "Operational "Operational Support Support Support Support Center Center Center Center Floor Plan" Organizational Chart" Dosimetry Log Sheet" Instrument Control Log 6, "Operational Support Center Request Form" 7, "Operational Support Center Response Team Form" 8, "Operational Support Center Response Team Checklist" 9, "Sequence of Events Form" 10, "Operational Support Center Priority Form" 6.1.2 6.1.3 6.1.4 6.1.5 6.1.6 6.1.7 6.1.8 6.1.9 6.1.10 PALISADES NUCLEAR PLANT EMERGENCY IMPLEMENTING PROCEDURE Proc No EI-4.2 Revision 14 Page 14 of 14 TITLE: OPERATIONAL SUPPORT CENTER ACTIVATION RECORDS Records generated by this procedure shall be filed in accordance with Palisades Administrative Procedure 10.46, "Plant Records." Refer to the record matrix attached to AP 10.46 for information needed to complete Record Indexing Form (Form 104).6.2 I Proc No EI-4.2 Attachment 1 Revision 14 Page 1 of 1 OPERATIONAL SUPPORT CENTER ACTIVATION LIST SECTION 1: ASSEMBLY AND ACCOUNTABILITY
- a. OSC habitable?
Yes_ No_ Classification Time b. Accountability completed.
Time c. Announce Key Players/Positions to OSC personnel.
Time d. Emergency Classification sign posted. e. Command and Control sign posted. SECTION 2: PHYSICAL ARRANGEMENT
- a. Layout per Attachment
- 2. b. Frisking station established.
- c. Dosimetry/Equipment control point established, rad controlled area, dosimetry records (Attachments 4, 5, and 6). d. Status boards in place. e. Sample station established.
- f. Communications with TSC and associated phone lines completed.
- g. Emergency MIS Computer.
OPERATIONAL SUPPORT CENTER FLOOR PLAN Proc No EI-4.2 Attachment 2 Revision 14 Page 1 of 1 vialn Lockaroom Aoesably Ae.o VI mainteanc.
Personnel OSC BOARDS OSC-1 -OSC Resources OSC-2 -Emergency Onsite El Monitoring Map OSC-3 -Response Teams OSC-4 -Monitoring Team Data** OSC-5 -OSC Priorities Board OSC-6 -Onsite Monitoring Board (Habitability Areas)
- OSC-7 Mile EPZ Map** OSC-8 -Sequence of Events Board OSC EMERGENCY KIT C c SA MIS COMPUTER CARTS "; G ARE STORED INSIDE CAGE FAN ROOM I .:. .Z OSC-5 04 oSc #1 If OSC $3 o9C #2 0 '1. 0 0 0 Lunch Room Assoembly Area V*OSC Phones -X 2596 (Chem) -x 2409 (HP) -X 2410 (HP Communicator) -X 2346 (General) -Direct Line to TSC -X 2109 OSC Director -X 2110 TIP -X 764-2730 (FAX) -X 2243 (Maint. Communicator) -OSC to Met Tower Line (HP Radio) -764-9994 Phone Jack under wall phone X2346 These boards are stored in the cage in the Fan Room behind OSC.
OPERATIONAL SUPPORT CENTER ORGANIZATIONAL CHART Proc No EI-4.2 Attachment 3 Revision 14 Page 1 of 1-w/Offslte Teams w/TSC HP*The OSC Director is responsible for maintaining accountability of AOs after the OSC is declared operational and the Shift Supervisor has released them to the OSC.
OPERATIONAL SUPPORT CENTER DOSIMETRY LOG SHEET Proc No EI-4.2 Attachment 4 Revision 14 Page 1 of 1 SSN Department Available Dose Total Dose Received Data Entered into MIS Name Time Out ED Reading Time ED Reading Dose Available Returned Received Dose Time Out ED Reading Time ED Reading Dose Available Returned Received Dose OPERATIONAL SUPPORT CENTER INSTRUMENT CONTROL LOG SHEET Proc No EI-4.2 Attachment 5 Revision 14 Page 1 of 1 Date: Name Instrument Consumers Location Time Contam Operation Instrument Type Energy # I Tagged OOS Out In Out !In OutJ In t I 4. 4 I + I + I +I -t 4 .4 4- * + 4 4 4. 4- 4. 4 4- 1 4- 4.7 1 I 4. 1 I 4 4 4 4- 4 1 1. 1 4. 1 1