ENS 49793: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 02/03/2014 CST
| event date = 02/03/2014 CST
| last update date = 02/05/2014
| last update date = 02/05/2014
| title = Texas Agreement State Report - Unable To Retract Radiography Camera Source
| title = Texas Agreement State Report - Unable to Retract Radiography Camera Source
| event text = The following information was obtained from the State of Texas via email:
| event text = The following information was obtained from the State of Texas via email:
On February 5, 2014, the Agency [Texas Department of Health] received notice that on February 3, 2014, the licensee was unable to retract an 84.5 curie iridium-192 source. The camera and guide tube had fallen from a 22 inch pipe while in use. This caused damage to the guide tube near the camera. The source was retrieved according to license conditions. The retrieval employee received 9 millirem from the retrieval. No member of the public was exposed at rates above limit. The damaged equipment was retired from service and will be replaced. The camera was an INC IR-100 with serial number 7231 and the source had serial number 11337C. Additional information will be provided when it is received in accordance with SA-300.
On February 5, 2014, the Agency [Texas Department of Health] received notice that on February 3, 2014, the licensee was unable to retract an 84.5 curie iridium-192 source. The camera and guide tube had fallen from a 22 inch pipe while in use. This caused damage to the guide tube near the camera. The source was retrieved according to license conditions. The retrieval employee received 9 millirem from the retrieval. No member of the public was exposed at rates above limit. The damaged equipment was retired from service and will be replaced. The camera was an INC IR-100 with serial number 7231 and the source had serial number 11337C. Additional information will be provided when it is received in accordance with SA-300.

Latest revision as of 21:51, 1 March 2018

ENS 49793 +/-
Where
Fugro Consultants Lp
Houston, Texas (NRC Region 4)
License number: 04322
Organization: Texas Department Of Health
Reporting
Agreement State
Time - Person (Reporting Time:+55.87 h2.328 days <br />0.333 weeks <br />0.0765 months <br />)
Opened: Gentry Hearn
13:52 Feb 5, 2014
NRC Officer: Howie Crouch
Last Updated: Feb 5, 2014
49793 - NRC Website