The following information was obtained from the State of
Texas via email:
On February 5, 2014, the Agency [Texas Department of Health] received notice that on February 3, 2014, the licensee was unable to retract an 84.5 curie iridium-192 source. The camera and guide tube had fallen from a 22 inch pipe while in use. This caused damage to the guide tube near the camera. The source was retrieved according to license conditions. The retrieval employee received 9 millirem from the retrieval. No member of the public was exposed at rates above limit. The damaged equipment was retired from service and will be replaced. The camera was an INC IR-100 with serial number 7231 and the source had serial number 11337C. Additional information will be provided when it is received in accordance with SA-300.
Texas Incident Number: I-9154