ML23059A051: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 18: Line 18:


=Text=
=Text=
{{#Wiki_filter:KPS Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 February 28, 2023 Pierre Saverot - Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 Docket No.:   Docket No. 71-9325 (HI-STAR 180 Model)
{{#Wiki_filter:KPS Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797- 0900 Fax (856) 797-0909
 
February 28, 2023
 
Pierre Saverot -Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards
 
ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555- 0001
 
Docket No.: Docket No. 71-9325 (HI-STAR 180 Model)


==Subject:==
==Subject:==
Withdrawal of License Amendment Request 9325-5 for Model No. HI-STAR 180 Transport Package
Withdrawal of License Amendment Request 9325-5for Model No. HI -STAR 180 Transport Package


==Reference:==
==Reference:==
Line 27: Line 35:


==Dear Mr. Saverot,==
==Dear Mr. Saverot,==
By {{letter dated|date=December 20, 2022|text=letter dated December 20, 2022}} [1], Holtec submitted License Amendment Request (LAR) 9325-5 for HI-STAR 180 Certificate of Compliance (CoC) Number 9325. Holtec no longer has a business need for this amendment, so to avoid wasting the USNRCs valuable resources, Holtec hereby requests that all review activities for this submittal be terminated in their entirety and the EPID Number be closed.


By {{letter dated|date=December 20, 2022|text=letter dated December 20, 2022}} [1], Holtec submitted License Amendment Request (LAR) 9325-5 for HI-STAR 180 Certificate of Compliance (CoC) Number 9325. Holtec no longer has a business need for this amendment, so to avoid wasting the USNRCs valuable resources, Holtec hereby requests that all review activities for this submittal be terminated in their entirety and the EPID Number be closed.
Holtec understands that the staff had some concerns on the structural evaluations submitted and we are following our corrective action process to evaluate and address any issues regardless of the withdraw of this application.
Holtec understands that the staff had some concerns on the structural evaluations submitted and we are following our corrective action process to evaluate and address any issues regardless of the withdraw of this application.
We thank the staff for the time spent reviewing the application and their diligence in providing valuable feedback.
We thank the staff for the time spent reviewing the application and their diligence in providing valuable feedback.
If you have any further questions, then please contact me at 856-797-0900, ext. 3951.
If you have any further questions, then please contact me at 856-797-0900, ext. 3951.
Doc. I.D.: 1553047-NRC Page 1 of 2


KPS Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Sincerely, Kimberly Manzione Director of Licensing Holtec International cc: Christopher OMullane (Holtec) via email Doc. I.D.: 1553047-NRC Page 2 of 2}}
Doc. I.D.: 1553047-NRC Page 1 of 2 KPS Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797- 0900 Fax (856) 797-0909
 
Sincerely,
 
Kimberly Manzione Director of Licensing Holtec International
 
cc: Christopher OMullane (Holtec) via email
 
Doc. I.D.: 1553047-NRC Page 2 of 2}}

Latest revision as of 06:24, 15 November 2024

International, Withdrawal of License Amendment Request 9325-5 for Model No. HI-STAR 180 Transport Package
ML23059A051
Person / Time
Site: 07109325
Issue date: 02/28/2023
From: Manzione K
Holtec
To: Pierre Saverot
Office of Nuclear Material Safety and Safeguards, Document Control Desk
References
1553047-NRC
Download: ML23059A051 (1)


Text

KPS Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797- 0900 Fax (856) 797-0909

February 28, 2023

Pierre Saverot -Project Manager Storage and Transportation Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards

ATTN: Document Control Desk U.S. Nuclear Regulatory Commission Washington, DC 20555- 0001

Docket No.: Docket No. 71-9325 (HI-STAR 180 Model)

Subject:

Withdrawal of License Amendment Request 9325-5for Model No. HI -STAR 180 Transport Package

Reference:

[1] Submittal of License Amendment Request 9325-5 for Model No. HI-STAR 180 Transport Package, Holtec Letter 1553046-NRC from Christopher OMullane (Holtec) to Pierre Saverot (USNRC), dated December 20, 2022; ADAMS Accession No. ML22354A142.

Dear Mr. Saverot,

By letter dated December 20, 2022 [1], Holtec submitted License Amendment Request (LAR) 9325-5 for HI-STAR 180 Certificate of Compliance (CoC) Number 9325. Holtec no longer has a business need for this amendment, so to avoid wasting the USNRCs valuable resources, Holtec hereby requests that all review activities for this submittal be terminated in their entirety and the EPID Number be closed.

Holtec understands that the staff had some concerns on the structural evaluations submitted and we are following our corrective action process to evaluate and address any issues regardless of the withdraw of this application.

We thank the staff for the time spent reviewing the application and their diligence in providing valuable feedback.

If you have any further questions, then please contact me at 856-797-0900, ext. 3951.

Doc. I.D.: 1553047-NRC Page 1 of 2 KPS Technology Campus, 1 Holtec Blvd, Camden, NJ 08104 Telephone (856) 797- 0900 Fax (856) 797-0909

Sincerely,

Kimberly Manzione Director of Licensing Holtec International

cc: Christopher OMullane (Holtec) via email

Doc. I.D.: 1553047-NRC Page 2 of 2