| title = Degradation | | title = Degradation of the Reactor Coolant System (Rcs) Pressure Boundary | ||
| event text = During inspection of the hot leg nozzles on RCP loop #2 in accordance with the Alloy 600 Program Plan during Refuel 12, evidence of leakage was identified on nozzle RC-IPT-0106B. This constitutes degradation of the RCS pressure boundary. Corrective action is being evaluated. | | event text = During inspection of the hot leg nozzles on RCP loop #2 in accordance with the Alloy 600 Program Plan during Refuel 12, evidence of leakage was identified on nozzle RC-IPT-0106B. This constitutes degradation of the RCS pressure boundary. Corrective action is being evaluated. | ||
RC-IPT-0106B is a pressure transmitter that taps off of reactor coolant system hot leg (loop) # 2 . The location of the Pressure transmitter is found in Waterford Unit 3, FSAR Chapter 5.1, Flow Diagram Reactor Coolant System, Figure 5.1-3. The license said that the picture indicates a small amount of boric acid crystals in the area of the leakage. Licensee did not know if the leakage is from a weld, pin hole leak, etc. | RC-IPT-0106B is a pressure transmitter that taps off of reactor coolant system hot leg (loop) # 2 . The location of the Pressure transmitter is found in Waterford Unit 3, FSAR Chapter 5.1, Flow Diagram Reactor Coolant System, Figure 5.1-3. The license said that the picture indicates a small amount of boric acid crystals in the area of the leakage. Licensee did not know if the leakage is from a weld, pin hole leak, etc. |
Latest revision as of 21:24, 1 March 2018
Where | |
---|---|
Waterford Louisiana (NRC Region 4) | |
Reporting | |
10 CFR 50.72(b)(3)(ii)(A), Seriously Degraded | |
LER: | 05000382/LER-2003-003 |
Time - Person (Reporting Time:+3.88 h0.162 days <br />0.0231 weeks <br />0.00531 months <br />) | |
Opened: | Oscar Pipkins 07:53 Oct 25, 2003 |
NRC Officer: | John Mackinnon |
Last Updated: | Oct 25, 2003 |