(One intermediate revision by the same user not shown)
Line 3: Line 3:
| facility = Paducah Gaseous Diffusion Plant
| facility = Paducah Gaseous Diffusion Plant
| Organization =  
| Organization =  
| license number = Gdp-1
| license number = GDP-1
| region = 2
| region = 2
| state = Kentucky
| state = Kentucky
Line 16: Line 16:
| event date = 11/22/2005 12:05 CST
| event date = 11/22/2005 12:05 CST
| last update date = 04/02/2007
| last update date = 04/02/2007
| title = Improper Criticality Spacing For Waste Drum
| title = Improper Criticality Spacing for Waste Drum
| event text = At 1205 CST, on 11-22-05 the Plant Shift Superintendent was notified that during waste drum remediation activities, a drum was discovered that was in violation of one leg of double contingency.  Drum #39666W has been determined to contain up to (deleted) g (grams) U235 exceeding the allowed (deleted) gram limit for NCS Spacing Exempt drums. This drum was previously located in an NCS (Nuclear Criticality Safety) Spacing Exempt storage area in violation of NCSA WMO-001 requirements. The drum was moved to the C-335 storage area under an approved Remediation Guide which established a safety basis for the movement of drums that had been roped off and posted per earlier direction. This drum is currently stored in a Temporary Fissile Storage Area maintaining a minimum 2 foot edge-to-edge spacing under NCSA WMO-001, which maintains double contingency.
| event text = At 1205 CST, on 11-22-05 the Plant Shift Superintendent was notified that during waste drum remediation activities, a drum was discovered that was in violation of one leg of double contingency.  Drum #39666W has been determined to contain up to (deleted) g (grams) U235 exceeding the allowed (deleted) gram limit for NCS Spacing Exempt drums. This drum was previously located in an NCS (Nuclear Criticality Safety) Spacing Exempt storage area in violation of NCSA WMO-001 requirements. The drum was moved to the C-335 storage area under an approved Remediation Guide which established a safety basis for the movement of drums that had been roped off and posted per earlier direction. This drum is currently stored in a Temporary Fissile Storage Area maintaining a minimum 2 foot edge-to-edge spacing under NCSA WMO-001, which maintains double contingency.
SAFETY SIGNIFICANCE OF EVENTS
SAFETY SIGNIFICANCE OF EVENTS

Latest revision as of 19:32, 24 November 2018

ENS 42165 +/-
Where
Paducah Gaseous Diffusion Plant
Paducah, Kentucky (NRC Region 2)
License number: GDP-1
Reporting
Response
Time - Person (Reporting Time:+-2.18 h-0.0908 days <br />-0.013 weeks <br />-0.00299 months <br />)
Opened: Kevin Beasley
15:54 Nov 22, 2005
NRC Officer: Bill Huffman
Last Updated: Apr 2, 2007
42165 - NRC Website