Regulatory Guide 4.13: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
(StriderTol Bot change)
 
(7 intermediate revisions by the same user not shown)
Line 1: Line 1:
{{Adams
{{Adams
| number = ML13350A201
| number = ML003739935
| issue date = 11/30/1976
| issue date = 07/31/1977
| title = Performance, Testing, and Procedural Specifications for Thermoluminescence Dosimetry: Environmental Applications
| title = Performance,Testing & Procedural Specifications for Thermoluminescence Dosimetry:Environmental Applications
| author name =  
| author name =  
| author affiliation = NRC/RES
| author affiliation = NRC/RES
Line 10: Line 10:
| license number =  
| license number =  
| contact person =  
| contact person =  
| document report number = RG-4.013
| document report number = RG-4.13 Rev 1
| document type = Regulatory Guide
| document type = Regulatory Guide
| page count = 2
| page count = 4
}}
}}
{{#Wiki_filter:U.S. NUCLEAR REGULATORY  
{{#Wiki_filter:Revision 1 U.S. NUCLEAR REGULATORY COMMISSION                                                                                       July 1977 REGULATORY GUIDE
COMMISSION
                                      OFFICE OF STANDARDS DEVELOPMENT
November 1976 REGULATORY  
                                                                    REGULATORY GUIDE 4.13 PERFORMANCE, TESTING, AND PROCEDURAL SPECIFICATIONS
GUIDE OFFICE OF STANDARDS  
                                                  FOR THERMOLUMINESCENCE DOSIMETRY:
DEVELOPMENT
                                                              ENVIRONMENTAL APPLICATIONS
REGULATORY  
GUIDE 4.13 PERFORMANCE, TESTING, AND PROCEDURAL  
SPECIFICATIONS
FOR THERMOLUMINESCENCE  
DOSIMETRY:
ENVIRONMENTAL  
APPLICATIONS


==A. INTRODUCTION==
==A. INTRODUCTION==
Section 20.105, "Permissible levels of radiation in unrestricted areas." of 10 CFR Part 20. "Standards for Protection Against Radiation." provides limits on levels of radiation in unrestricted areas resulting from possession, use. or transfer or NRC-licensed radioac-tive material.
criteria for TLD systems used for this purpose. It also provides procedures for calibration, field application,                                I*
      Section 20.105, "Permissible levels of radiation in                                   and reporting. It does not apply to TLD systems used unrestricted areas," of 10 CFR Part 20, "Standards                                       for the purpose of determining occupational ex for Protection Against Radiation," provides limits on                                     posure.


Section 20.106, "Radioactivity in ef-fluents to unrestricted areas," of 10 CFR Part 20 prohibits a licensee from releasing to an unrestricted area radioactive materials in concentrations that ex-ceed limits specified in 10 CFR Part 20 except as otherwise authorized in a license issued by the Com-mission. Section 20.201. "Surveys." of 10 CFR Part result of normal operations.
levels of radiation in unrestricted areas resulting from                                                              


including anticipated operational occurrences, and .s 'the result of postulated accidents."hernioluninescence dcs!m'§krp (TlD) is widely used to measure levels o ~fý4X`d-gnnia radiation in the environs of NRC41icenkd nui61iear facilities.
==B. DISCUSSION==
possession, use, or transfer of NRC-licensed radioac tive material. Section 20.201, "Surveys," of 10 CFR                                            Working Group 9 of the Health Physics Society Part 20 further requires that a licensee conduct sur                                      Standards Committee for American National Stan veys as may be necessary to comply with the regula                                        dards Institute (ANSI) Committee N 13 on Radiation tions of 10 CFR Part 20 including, when appropriate,                                      Protection has prepared a standard that specifies the measurement of levels of radiation.                                                  minimum acceptable performance of TLDs used for Paragraph IV.B(2) of Appendix I, "Numerical                                          environmental measurements; outlines methods to Guides for Design Objectives and Limiting Condi                                          test for compliance; and provides procedures for tions for Operation to Meet the Criterion 'As Low As                                      calibration, field application, and reporting. This Is Reasonably Achievable' for Radioactive Material                                        standard was approved by the N13 Committee. It in Light-Water-Cooled Nuclear Power Reactor Ef                                            was subsequently approved and designated N545 fluents," to 10 CFR Part 50, "Licensing of Produc                                          1975, by ANSI on August 20, 1975.1 tion and Utilization Facilities,"                               requires that
,,
                                                                                                  The specification of performance criteria of ther licensees establish appropriate surveillance and                                          moluminescence dosimetry and the verification of the monitoring programs to provide data on measurable                                        actual performance require appropriate statistical levels of radiation and radioactive materials in the en                                  concepts and techniques. Because wide applicability vironment.                                                                                is intended, ANSI N545-1975 as well as the provi sions and clarifications given below in the regulatory General Design Criterion 64, "Monitoring radioactivity releases," of Appendix A, "General                                        position are confined to simple statistical concepts Design Criteria for Nuclear Power Plants," to 10                                          and prescribe no specific statistical techniques. In fact, the implementation of some specifications by CFR Part 50 requires that nuclear power plant                                            rigorous statistical methods may prove difficult for designs provide means for monitoring the plant en virons for radioactivity that may be released as the                                      some users of the guide. Therefore, good approx result of normal operations, including anticipated                                        imate statistical methods are acceptable.


This guide provides miniimuni acceptable performance criteria for TLD.sysirns used for this purpose. It also provides proeederes f-caibration, field application.
operational occurrences, and as the result of postulated accidents.


and reporting,-\'" ;\ ,
* Lines indicate substantive changes from previous issue.


====l. DISCUSSION====
'ANSI N545-1975, "Performance, Testing, and Procedural Thermoluminescence dosimetry (TLD) is widely                                          Specification for Thermoluminescence Dosimetry (Environmental used to measure levels of X and gamma radiation in                                        Applications)" may be obtained from the American National Standards Institute, 1430 Broadway, New York, New York the environs of NRC-licensed nuclear facilities. This                                      10018.
20 further requires that a licensee conduct surveys as, Wikjbg Gioup 9 of the Health Physics Society may be necessary to comply with the regulations of Z',`. nd,4.rdiý1Committee for American National Stan-10 CFR Part 20 including, when appropriate, the ain Committee (ANSI) N13 on Radiation measurement of levels of radiation.


,. .Plection has prepared a standard that specifies acceptable performance of TLDs used for Section IV.B of Appendix I, "Numerical G1.4 s mt'asurements:  
guide provides minimum acceptable performance USNRC REGULATORY GUIDES                                            Comments should be sent to the Secretary of the Commission, US. Nuclear Regu latory Commission, Washington, D.C. 20555. Attention: Docketing and Service Regulatory Guides are issued to describe and make available to the public methods        Branch.
outlines methods to for Design Objectives and Limiting Cor04ti'iohs gy test for compliance:
and provides procedures for Operation to Meet the Criterion
'As A.0ow A Is calibration, field application, and reporting.


This Reasonably Achievable'  
acceptable to the NRC staff of implementing specific parts of the Commission's regulations, to delineate techniques used by the staff in evaluating specific problems  The guides are issued in the following ten broad divisions or postulated accidents, or to provide guidance to applicants. Regulatory Guides                                                      6. Products required.  1. Power Reactors are not substitutes for regulations, and compfiance with them is not                                                                  7. Transportation will be accept- 2. Research and Test Reactors Methods and solutions different from those set out in the guides                                                                      9. Antitrust Review the issuance or continuance  4. Environmental and Siting able if they provide a basis for the findings requisite to
for Radioactivea eri4l in standard was prepared under the direction of the Light-Water-Cooled Nuclear Power Re'tGOP"Ef- Health Physics Society Standards Committee and fluents." to 10 CFR Part 50, "Licensing of Produc- was processed and approved for submittal to ANSI tion and Utilization requires that by the American National Standards Committee on licensees establish appr fi- surveillance and Radiation Protection.
                                                                                              5. Materials and Plant Protection          10. General of a permit or license by the Commission.


NI1. It was subsequently ap-monitoring programs to on measurable proved and designated N545-1975 by the ANSI levels of radiation a io i.e materi,fls in the en- Board of Standards Review on August 20. 1975.1 vironment, General i *iW ion 64, "Monitoring radioactivit e es, of' Appendix A, "General Design Crite or Nuclear Power Plants," to 10 CFR Part 50 uires that nuclear power plant designs provide means for monitoring the plant en-virons for radioactivity that may be released as the The specification of performance criteria of ther-moluminescence dosimetry and the verification of the actual performance require appropriate statistical
Comments and suggestions for improvements in these guides are encouraged at all          Requests for single copies of issued guides (which may be reproduced) or for place times, and guides will be revised, as appropriate, to accommodate comments and            ment on an automatic distribution list for single copies of future guides in specific to reflect new information or experience. This guide was revised as a result of          divisions should be made in writing to the US. Nuclear Regulatory Commission, Washington, D.C.    20555, Attention      Director. Oivision of Document Control substantive comments received from the public and additional staff review,
'ANSI N545-1975, "P'erfornmance.


Testing. and Procedural Spcificalion Fir Th,:rlnoluminesrencrt:
No specific criteria for good approximation are                      e. Section 7.2 of ANSI N545-1975 permits the re prescribed. However, the user should judge whether                    quirements of Section 4 of the standard to be satisfied the sample size is adequately large for the approxima                by reference to prior documents. Test results tion and whether the distribution of the measure                      provided by vendors are examples of such docu ments is sufficiently close to that assumed in the                    ments. Therefore, when requirements of Section 4 of analysis. Problems relating to underlying distribu                    the standard can be met by reference to test results tions can be avoided by the use of nonparametric                      provided by a vendor or other source, additional tests methods. Some of the specifications that are stated in                by a licensee are not needed.
Dou.imetry (Envirdnniciltal Applications)'" moly he (iblaind From the Americain Naliontal Standards Inslilttul.


1430 Bro:dway, New York. New Yoirk t(X)IX.USNRC REGULATORY
terms of standard deviations can be reformulated in nearly equivalent specifications for tolerance limits                    f. The appendixes to ANSI N545-1975 are not a for which simple nonparametric methods are                            part of the ANSI standard or of this regulatory guide, available. Such reformulations are also acceptable.                   which endorses the standard. However, the appen A. Hald2 and W. J. Conover3 are useful reference                      dixes do provide useful information on the topics sources for parametric and nonparametric methods,                    covered.
GUIDES Comments should be sent to the Secretary of the Commission.


U.S. Nuclea, Regulatory Guides are issued to describe and make available to the public ARgulatoty Commission.
respectively.


Washington.
==C. REGULATORY POSITION==
If every TLD is individually calibrated, the popula tion parameters for certain errors can be computed                      The requirements and recommendations for per directly, and statistical inference is not needed for                formance specifications, testing procedures, calibra specifications relating to these errors.                              tion procedures, field procedures, and reporting procedures that are included in ANSI N545-1975 are generally acceptable to the NRC staff as the basis for Comments received on this guide and subsequent                    using thermoluminescence dosimetry for the discussions of these comments have indicated a need                    measurement of X and gamma radiation in the en for the following emphasis on, or clarification of, sec                virons of NRC-licensed facilities subject to the fol tions of the guide and ANSI N545-1975 in order to                      lowing additional provisions and qualifications.


0 C 2055, Attention Docketlrg and Asguatoy Gudearei~sud t decrib An mae anitate o th pul'c Serivice Section methods acceptable to ihe. IRC staff of implementing sppcihic pe'-t.of ine S Se*tion Commission's regulations, to delineate techniques used by the staf.f i eyrelu 1he guide% are issued in the following ten broad divi.iolls sting specific problems or postulated accidents Ot to provide guidrnce to apphi cants. Regulatory Guides ate not substitutes tot regulations, and compliance I Power Reactors 6 Piuducls with them is not required Methods and solutions dliffelrent from those set on't in 2. Research and Test Reactors I Ttanspocietlnn the guides wilt be acceptable if they provide a basis lot the findings teqwus.te to 3 Fuels and Matetials Facilities
avoid misinterpretations:
8 Uccupational Heallh the isr.ance or conlinuance ola permit or license by the Commission
                                                                          1. Section 3, "Performance Specifications," of a. In this guide, the expression environs of NRC                  ANSI N545-1975 should be supplemented by the fol licensedfacilities includes both the term environment                  lowing statement: "Subsection 4.2.4 shall apply also as defined in ANSI N545-1975 and the phrase un                        to the subsections 3.1 and 3.3."
4 EnvlronmentAlend Siling 9 Antitiust Review Comments and suggestions fot improvements in these guides ate encouraged
restricted areas as defined in 10 CFR Part 20.
6 Matetials arid Plant Protection
10 General at all times, and guides will be revised, as appropriate, to accommodate com meits and to reflect new information or eopetience However. comnitnts on Copies of published guides may be obtained by written request indrcatirrg the this guide, io received within abuul two nmonths after its issuance, will be part divisions desired to the U S Nuclear Regulatory Conintlision.


Washingtonr.
2. Instead of Section 3.1 of ANSI N545-1975, the b. In Section 2, "Definitions," of ANSI N545                        following should be used: "The performance of the
1975, the distinction between thermoluminescence                      TLD system shall be determined under laboratory dosimeter (TLD) and thermoluminescence (TL)                            conditions and in a known radiation field with an ex phosphor should be noted. As defined in ANSI N545                      posure equal to that resulting from an exposure rate
1975, a TLD can, and usually does, contain multiple                    of 101MR/hr during the field cycle. Ninety-five per TL phosphors or. otherwise provides for multiple                      cent of the measurements shall fall within 10% of the readings of the exposure. When multiple readings are                  known exposure."
used for the measurement of the response of a TLD,
that response is an average of the individual readings.                  3. Instead of Section 3.3 of ANSI N545-1975, the ANSI N545-1975 refers to these average values rather                  following should be used: "Ninety-five percent of the than to the individual readings.                                      final values (after all appropriate corrections to the measurements are applied, including those for errors c. Regulatory position 3 of this guide and Section                  expected under field conditions) shall differ from the
3.3 of ANSI N545-1975 refer to the overall error in                  correct value by less than 30% of the correct value."
the total field exposure. No method is specified for interpreting field exposures to isolate contributions                    4. Instead of Section 4.3.1 of ANSI N545-1975, attributable to a nuclear facility, and no limit is                  the following should be used: "Uniformity shall be specified on the error associated with estimates of the                determined by giving TLDs from the same batch an exposure attributable to the facility.                                exposure equal to that resulting from an exposure rate of lOtR/hr during the field cycle. The response d. Section 6.3.1 of ANSI N545-1975 specifies field                  obtained shall have a relative standard deviation exposure at a height of 1 meter above the ground;                    (coefficient of variation) of less than 7.5%."
however, Section 6.3.3 permits exposure at other heights.


0 f ticultaly useful in evaluatrng the need for art early revision 205. Attention ODrector.
5. Instead of Section 4.3.2 of ANSI N545-1975,
2A. Hald, Statistical Theory with Engineering Applications, John      the following should be used: "Reproducibility shall Wiley & Sons, Inc., 1952.                                            be determined by giving one TLD repeated exposures
3W.J. Conover, PracticalNonparametric Statistics, John Wiley &        equal to that resulting from an exposure rate of 10
Sons, Inc., 1971.                                                    juR/hr during the field cycle. The responses shall have
                                                                4.13-2


Office of Standards Development concepts and techniqu,.-s.
a relative standard deviation (coefficient of variation)        This guide reflects current NRC staff practice.


Because w!de applicability is intended.
I
of less than 3.0%."                                          Therefore, except in those cases in which the appli cant or licensee proposes an acceptable alternative method, the staff is using and will continue to use the method described herein in evaluating an applicant's


ANSI N545. 1975 as well as the provi-sions and clarifications given below in the regulatory position are confined to simple statistical concepts and prescribe no specific statistical techniques.
==D. IMPLEMENTATION==
 
or licensee's capability for and performance in com plying with specified portions of the Commission's The purpose of this section is to provide informa          regulations until this guide is revised as a result of tion to applicants and licensees regarding the NRC           suggestions from the public or additional staff staff's plans for using this regulatory guide.               review.
In fact. the implem-.-ntation of some specifications by rigorous statistical methods may prove difficult for some users of the guide. Therefore, good approx-imate statistical methods are acceptable.
 
No specific criteria for good approximation are prescribed.
 
However. the user should judge whether the sample site is adequately large for the approxima- tion and w%+-ether the distribution of the measure-m'ents is sutfiiently close to that assumed in the analysis.
 
Pr(.blems relating to underlying distribu-tions can he 'tvoided by the use of nonparametric methods Some .-f the specifications which are stated in terms of standard deviations can be reformulated in nearly equivalent specifications for tolerance limits for %%hich simple nonparametric methods are available.
 
Such reformulations are also acceptable.
 
A. [Iaid: and WV. J. Conover' are useful reference sources for parametric and nonparametric methods.respectively.
 
If every TLD i; individually calibrated, the popula-tion parameters for certain errors can be computed directly, and statistical inference is not needed for specifications relating to these errors.C. REGULATORY
POSITION The requirements and recommendations for per-formance specifications.
 
testing procedures.
 
calibra-tion procedures, field procedures, and reporting procedures that are included in ANSI N545-1975 are generally acceptable to the NRC staff as the basis for using thermoluminescence dosimetry for the measurement of X and gamma: radiation in the en-virons of NRC-licensed facilitir:.-
subject to the fol-lowing additional provisiu.is
:J qualificati~ms.


1. Section 3. -IPerforma..,e Specifications." of ANSI N 545-1975 should bt' cupplemented by the fol-lowing statement: "Each pt rformance specification shall be verified at the 95% confidence level." A. [laid. Stati.;tical "lhior'v 'ith Eiginierint
4.13-3
..lpplicatimts.


John k\\ e% & sons. Inc.. 1t52.'\%. J. (d'ono.er.
UNITED STATES
 
NUCLEAR REGULATORY COMMISSION
Iracci .\'operait,'tri .ttijis. John Wiley &sn.qo, Inc.. I19T1.2. Instead of Section 3.1 of ANSI N545-1975, the following should be used: "The performance of the TLD system shall be determined under laboratory conditions and in a known radiation field with an ex-posure equal to that resulting from an exposure rate of 10 p R/hr during the field cycle. Ninety-five per-cent of the measurements shall fall within 10% of the known exposure." 3. Instead of Section 3.3 of ANSI N545-1975, the following should be used: "Ninety-five percent of the final value-:- (after all appropriate corrections to the measurements are applied, including those for errors expect.d under field conditions)
    WASHINGTON, D. C. 20555 POSTAGE AND FEES PAID
shall differ from the correct value by less than 30% of the correct value." 4. Instead of Section 4.3.1 of ANSI N545-1975.
      OFFICIAL BUSINESS        U.S. NUCLEAR REGULATORY
 
  PENALTY FOR PRIVATE USE, $300        COMMISSION}}
the folLwing should be used: "Uniformity shall be determined by giving TLDs from the same batch an exposure equal to that resulting from an exposure rate of 10 a R/hr during the field cycle. The response obtained shall have a relative standard deviation (coefficient of variation)
of less than 7.5%." 5. Instead of Section 4.3.2 of ANSI N545-1975, the following should be used: "Reproducibility shall be determined by givinL- one TLD repeated exposures equal to that resulting from an exposure rate of 10 p R/hr during the field cycle. The responses shall have a relative standard deviation (coefficient of variation)
of less than 3.0%."-
 
==D. IMPLEMENTATION==
The purpose of this section is to provide inrorma-tion to applicants and licensees regarding the staffs plans for utilizing this regulatory guide.Except in those cases in which the applicant proposes an acceptable alternative method for com-plying with specified portions of the Commission's regulations, the method described herein will be used in the evaluation of operating license applications docketed after July 15, 1977.If an applicant wishes to use this regulatory guide in developing submittals for applications docketed on or before July 15. 1977, the pertinent portions of the application will be evaluated on the basis of this guide.4.13-2}}


{{RG-Nav}}
{{RG-Nav}}

Latest revision as of 10:27, 28 March 2020

Performance,Testing & Procedural Specifications for Thermoluminescence Dosimetry:Environmental Applications
ML003739935
Person / Time
Issue date: 07/31/1977
From:
Office of Nuclear Regulatory Research
To:
References
RG-4.13 Rev 1
Download: ML003739935 (4)


Revision 1 U.S. NUCLEAR REGULATORY COMMISSION July 1977 REGULATORY GUIDE

OFFICE OF STANDARDS DEVELOPMENT

REGULATORY GUIDE 4.13 PERFORMANCE, TESTING, AND PROCEDURAL SPECIFICATIONS

FOR THERMOLUMINESCENCE DOSIMETRY:

ENVIRONMENTAL APPLICATIONS

A. INTRODUCTION

criteria for TLD systems used for this purpose. It also provides procedures for calibration, field application, I*

Section 20.105, "Permissible levels of radiation in and reporting. It does not apply to TLD systems used unrestricted areas," of 10 CFR Part 20, "Standards for the purpose of determining occupational ex for Protection Against Radiation," provides limits on posure.

levels of radiation in unrestricted areas resulting from

B. DISCUSSION

possession, use, or transfer of NRC-licensed radioac tive material. Section 20.201, "Surveys," of 10 CFR Working Group 9 of the Health Physics Society Part 20 further requires that a licensee conduct sur Standards Committee for American National Stan veys as may be necessary to comply with the regula dards Institute (ANSI) Committee N 13 on Radiation tions of 10 CFR Part 20 including, when appropriate, Protection has prepared a standard that specifies the measurement of levels of radiation. minimum acceptable performance of TLDs used for Paragraph IV.B(2) of Appendix I, "Numerical environmental measurements; outlines methods to Guides for Design Objectives and Limiting Condi test for compliance; and provides procedures for tions for Operation to Meet the Criterion 'As Low As calibration, field application, and reporting. This Is Reasonably Achievable' for Radioactive Material standard was approved by the N13 Committee. It in Light-Water-Cooled Nuclear Power Reactor Ef was subsequently approved and designated N545 fluents," to 10 CFR Part 50, "Licensing of Produc 1975, by ANSI on August 20, 1975.1 tion and Utilization Facilities," requires that

,,

The specification of performance criteria of ther licensees establish appropriate surveillance and moluminescence dosimetry and the verification of the monitoring programs to provide data on measurable actual performance require appropriate statistical levels of radiation and radioactive materials in the en concepts and techniques. Because wide applicability vironment. is intended, ANSI N545-1975 as well as the provi sions and clarifications given below in the regulatory General Design Criterion 64, "Monitoring radioactivity releases," of Appendix A, "General position are confined to simple statistical concepts Design Criteria for Nuclear Power Plants," to 10 and prescribe no specific statistical techniques. In fact, the implementation of some specifications by CFR Part 50 requires that nuclear power plant rigorous statistical methods may prove difficult for designs provide means for monitoring the plant en virons for radioactivity that may be released as the some users of the guide. Therefore, good approx result of normal operations, including anticipated imate statistical methods are acceptable.

operational occurrences, and as the result of postulated accidents.

  • Lines indicate substantive changes from previous issue.

'ANSI N545-1975, "Performance, Testing, and Procedural Thermoluminescence dosimetry (TLD) is widely Specification for Thermoluminescence Dosimetry (Environmental used to measure levels of X and gamma radiation in Applications)" may be obtained from the American National Standards Institute, 1430 Broadway, New York, New York the environs of NRC-licensed nuclear facilities. This 10018.

guide provides minimum acceptable performance USNRC REGULATORY GUIDES Comments should be sent to the Secretary of the Commission, US. Nuclear Regu latory Commission, Washington, D.C. 20555. Attention: Docketing and Service Regulatory Guides are issued to describe and make available to the public methods Branch.

acceptable to the NRC staff of implementing specific parts of the Commission's regulations, to delineate techniques used by the staff in evaluating specific problems The guides are issued in the following ten broad divisions or postulated accidents, or to provide guidance to applicants. Regulatory Guides 6. Products required. 1. Power Reactors are not substitutes for regulations, and compfiance with them is not 7. Transportation will be accept- 2. Research and Test Reactors Methods and solutions different from those set out in the guides 9. Antitrust Review the issuance or continuance 4. Environmental and Siting able if they provide a basis for the findings requisite to

5. Materials and Plant Protection 10. General of a permit or license by the Commission.

Comments and suggestions for improvements in these guides are encouraged at all Requests for single copies of issued guides (which may be reproduced) or for place times, and guides will be revised, as appropriate, to accommodate comments and ment on an automatic distribution list for single copies of future guides in specific to reflect new information or experience. This guide was revised as a result of divisions should be made in writing to the US. Nuclear Regulatory Commission, Washington, D.C. 20555, Attention Director. Oivision of Document Control substantive comments received from the public and additional staff review,

No specific criteria for good approximation are e. Section 7.2 of ANSI N545-1975 permits the re prescribed. However, the user should judge whether quirements of Section 4 of the standard to be satisfied the sample size is adequately large for the approxima by reference to prior documents. Test results tion and whether the distribution of the measure provided by vendors are examples of such docu ments is sufficiently close to that assumed in the ments. Therefore, when requirements of Section 4 of analysis. Problems relating to underlying distribu the standard can be met by reference to test results tions can be avoided by the use of nonparametric provided by a vendor or other source, additional tests methods. Some of the specifications that are stated in by a licensee are not needed.

terms of standard deviations can be reformulated in nearly equivalent specifications for tolerance limits f. The appendixes to ANSI N545-1975 are not a for which simple nonparametric methods are part of the ANSI standard or of this regulatory guide, available. Such reformulations are also acceptable. which endorses the standard. However, the appen A. Hald2 and W. J. Conover3 are useful reference dixes do provide useful information on the topics sources for parametric and nonparametric methods, covered.

respectively.

C. REGULATORY POSITION

If every TLD is individually calibrated, the popula tion parameters for certain errors can be computed The requirements and recommendations for per directly, and statistical inference is not needed for formance specifications, testing procedures, calibra specifications relating to these errors. tion procedures, field procedures, and reporting procedures that are included in ANSI N545-1975 are generally acceptable to the NRC staff as the basis for Comments received on this guide and subsequent using thermoluminescence dosimetry for the discussions of these comments have indicated a need measurement of X and gamma radiation in the en for the following emphasis on, or clarification of, sec virons of NRC-licensed facilities subject to the fol tions of the guide and ANSI N545-1975 in order to lowing additional provisions and qualifications.

avoid misinterpretations:

1. Section 3, "Performance Specifications," of a. In this guide, the expression environs of NRC ANSI N545-1975 should be supplemented by the fol licensedfacilities includes both the term environment lowing statement: "Subsection 4.2.4 shall apply also as defined in ANSI N545-1975 and the phrase un to the subsections 3.1 and 3.3."

restricted areas as defined in 10 CFR Part 20.

2. Instead of Section 3.1 of ANSI N545-1975, the b. In Section 2, "Definitions," of ANSI N545 following should be used: "The performance of the

1975, the distinction between thermoluminescence TLD system shall be determined under laboratory dosimeter (TLD) and thermoluminescence (TL) conditions and in a known radiation field with an ex phosphor should be noted. As defined in ANSI N545 posure equal to that resulting from an exposure rate

1975, a TLD can, and usually does, contain multiple of 101MR/hr during the field cycle. Ninety-five per TL phosphors or. otherwise provides for multiple cent of the measurements shall fall within 10% of the readings of the exposure. When multiple readings are known exposure."

used for the measurement of the response of a TLD,

that response is an average of the individual readings. 3. Instead of Section 3.3 of ANSI N545-1975, the ANSI N545-1975 refers to these average values rather following should be used: "Ninety-five percent of the than to the individual readings. final values (after all appropriate corrections to the measurements are applied, including those for errors c. Regulatory position 3 of this guide and Section expected under field conditions) shall differ from the

3.3 of ANSI N545-1975 refer to the overall error in correct value by less than 30% of the correct value."

the total field exposure. No method is specified for interpreting field exposures to isolate contributions 4. Instead of Section 4.3.1 of ANSI N545-1975, attributable to a nuclear facility, and no limit is the following should be used: "Uniformity shall be specified on the error associated with estimates of the determined by giving TLDs from the same batch an exposure attributable to the facility. exposure equal to that resulting from an exposure rate of lOtR/hr during the field cycle. The response d. Section 6.3.1 of ANSI N545-1975 specifies field obtained shall have a relative standard deviation exposure at a height of 1 meter above the ground; (coefficient of variation) of less than 7.5%."

however, Section 6.3.3 permits exposure at other heights.

5. Instead of Section 4.3.2 of ANSI N545-1975,

2A. Hald, Statistical Theory with Engineering Applications, John the following should be used: "Reproducibility shall Wiley & Sons, Inc., 1952. be determined by giving one TLD repeated exposures

3W.J. Conover, PracticalNonparametric Statistics, John Wiley & equal to that resulting from an exposure rate of 10

Sons, Inc., 1971. juR/hr during the field cycle. The responses shall have

4.13-2

a relative standard deviation (coefficient of variation) This guide reflects current NRC staff practice.

I

of less than 3.0%." Therefore, except in those cases in which the appli cant or licensee proposes an acceptable alternative method, the staff is using and will continue to use the method described herein in evaluating an applicant's

D. IMPLEMENTATION

or licensee's capability for and performance in com plying with specified portions of the Commission's The purpose of this section is to provide informa regulations until this guide is revised as a result of tion to applicants and licensees regarding the NRC suggestions from the public or additional staff staff's plans for using this regulatory guide. review.

4.13-3

UNITED STATES

NUCLEAR REGULATORY COMMISSION

WASHINGTON, D. C. 20555 POSTAGE AND FEES PAID

OFFICIAL BUSINESS U.S. NUCLEAR REGULATORY

PENALTY FOR PRIVATE USE, $300 COMMISSION