ENS 46435: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 11/10/2010 00:24 EST
| event date = 11/10/2010 00:24 EST
| last update date = 11/23/2010
| last update date = 11/23/2010
| title = Telephone Notification In Lieu Of Written Ler - Invalid Actuation Of Motor Driven Auxiliary Feedwater Pump
| title = Telephone Notification in Lieu of Written Ler - Invalid Actuation of Motor Driven Auxiliary Feedwater Pump
| event text = Event:  Invalid actuation of the 'B' Motor Driven Auxiliary Feedwater (MDAFW) pump.
| event text = Event:  Invalid actuation of the 'B' Motor Driven Auxiliary Feedwater (MDAFW) pump.
Report Type:  This 60-day telephone notification is being made under 10CFR50.73(a)(2)(iv)(A) and 10CFR50.73(a)(1).
Report Type:  This 60-day telephone notification is being made under 10CFR50.73(a)(2)(iv)(A) and 10CFR50.73(a)(1).

Latest revision as of 22:08, 1 March 2018

ENS 46435 +/-
Where
Harris Duke Energy icon.png
North Carolina (NRC Region 2)
Reporting
10 CFR 50.73(a)(1), Submit an LER, Invalid Actuation
Time - Person (Reporting Time:+322.18 h13.424 days <br />1.918 weeks <br />0.441 months <br />)
Opened: Kimberly Bass
15:35 Nov 23, 2010
NRC Officer: Donald Norwood
Last Updated: Nov 23, 2010
46435 - NRC Website
Loading map...