ENS 52427: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by Mark Hawes)
 
(Created page by program invented by StriderTol)
 
Line 16: Line 16:
| event date = 12/09/2016 EST
| event date = 12/09/2016 EST
| last update date = 12/13/2016
| last update date = 12/13/2016
| title = Part 21 Notification - Defective Safety-Related Relays Supplied By Te Connectivity
| title = Part 21 Notification - Defective Safety-Related Relays Supplied by Te Connectivity
| event text = The following information is a summary of a letter of nonconformance submitted by TE Connectivity:
| event text = The following information is a summary of a letter of nonconformance submitted by TE Connectivity:
Limerick Generating Station reported that four TE Connectivity supplied relays failed power labs analysis. The relays are TE part number 1-1431775, ETR14I3D004. The affected relays appear to be those in date code ranges 1604 and 1612.
Limerick Generating Station reported that four TE Connectivity supplied relays failed power labs analysis. The relays are TE part number 1-1431775, ETR14I3D004. The affected relays appear to be those in date code ranges 1604 and 1612.

Latest revision as of 20:43, 1 March 2018

ENS 52427 +/-
Where
Te Connectivity
Fairview, North Carolina (NRC Region 1)
Organization: Te Connectivity
Reporting
10 CFR 21.21(a)(2), Interim Report for Comply or Defect in Component
Time - Person (Reporting Time:+107.13 h4.464 days <br />0.638 weeks <br />0.147 months <br />)
Opened: Oswaldo Vargas
16:08 Dec 13, 2016
NRC Officer: Howie Crouch
Last Updated: Dec 13, 2016
52427 - NRC Website