| title = Shine Medical Technologies V. 0 - Chapter 08 - Figure 8a2.2-001 | | title = Shine Medical Technologies V. 0 - Chapter 08 - Figure 8a2.2-001 | ||
| author name = Bynum R | | author name = Bynum R | ||
| author affiliation = Shine Medical Technologies, Inc | | author affiliation = Shine Medical Technologies, Inc | ||
| addressee name = | | addressee name = | ||
| Line 14: | Line 14: | ||
| page count = 1 | | page count = 1 | ||
}} | }} | ||
=Text= | |||
{{#Wiki_filter:Chapter 8 - Electrical Power Systems Emergency Electrical Power Systems SHINE Medical Technologies Rev. 0 Figure 8a2.2 One-Line Diagram - Uninterruptible Electrical Power Supply System 250V DC DISTRIBUTION PANEL A, CLASS 1E UPS A CLASS 1E 250V DC CLASS 1E BATTERY A CLASS 1E BATTERY CHARGER A 480V-208Y/120V 3Ø, 4W, 60 Hz | |||
+/- 0.5% | |||
VOLTAGE REGULATING TRANSFORMER A BUS A VOLTAGE REGULATING XFMR ASSEMBLY A CLASS 1E 250V DC DISTRIBUTION PANEL B, CLASS 1E UPS B CLASS 1E NON-CLASS 1E LEGEND: | |||
NON-CLASS 1E TO CLASS 1E ISOLATOR 250V DC CLASS 1E BATTERY B CLASS 1E BATTERY CHARGER B 208Y/120V AC UPS CLASS 1E BUS B VOLTAGE REGULATING XFMR ASSEMBLY B CLASS 1E DISCHARGE TEST FACILITY 480V AC SDG BUS DISCHARGE TEST FACILITY 480V AC SDG BUS NON-CLASS 1E INVERTER AC THYRISTOR SWITCH MANUAL BYPASS INVERTER AC THYRISTOR SWITCH MANUAL BYPASS FACILITY ONE-LINE DIAGRAM DRAWING NUMBER LATER 480V-208Y/120V 3Ø, 4W, 60 Hz | |||
+/- 0.5% | |||
VOLTAGE REGULATING TRANSFORMER B}} | |||
Latest revision as of 14:21, 10 January 2025
| ML15043A366 | |
| Person / Time | |
|---|---|
| Site: | SHINE Medical Technologies |
| Issue date: | 02/06/2015 |
| From: | Bynum R Shine Medical Technologies |
| To: | Office of Nuclear Reactor Regulation |
| Lynch S | |
| References | |
| SHINE, SHINE.SUBMISSION.8, SHN.PSAR.P, SHN.PSAR.P.3 | |
| Download: ML15043A366 (1) | |
Text
Chapter 8 - Electrical Power Systems Emergency Electrical Power Systems SHINE Medical Technologies Rev. 0 Figure 8a2.2 One-Line Diagram - Uninterruptible Electrical Power Supply System 250V DC DISTRIBUTION PANEL A, CLASS 1E UPS A CLASS 1E 250V DC CLASS 1E BATTERY A CLASS 1E BATTERY CHARGER A 480V-208Y/120V 3Ø, 4W, 60 Hz
+/- 0.5%
VOLTAGE REGULATING TRANSFORMER A BUS A VOLTAGE REGULATING XFMR ASSEMBLY A CLASS 1E 250V DC DISTRIBUTION PANEL B, CLASS 1E UPS B CLASS 1E NON-CLASS 1E LEGEND:
NON-CLASS 1E TO CLASS 1E ISOLATOR 250V DC CLASS 1E BATTERY B CLASS 1E BATTERY CHARGER B 208Y/120V AC UPS CLASS 1E BUS B VOLTAGE REGULATING XFMR ASSEMBLY B CLASS 1E DISCHARGE TEST FACILITY 480V AC SDG BUS DISCHARGE TEST FACILITY 480V AC SDG BUS NON-CLASS 1E INVERTER AC THYRISTOR SWITCH MANUAL BYPASS INVERTER AC THYRISTOR SWITCH MANUAL BYPASS FACILITY ONE-LINE DIAGRAM DRAWING NUMBER LATER 480V-208Y/120V 3Ø, 4W, 60 Hz
+/- 0.5%
VOLTAGE REGULATING TRANSFORMER B