| title = Shine Medical Technologies V. 0 - Chapter 08 - Figure 8a2.2-001
| title = Shine Medical Technologies V. 0 - Chapter 08 - Figure 8a2.2-001
| author name = Bynum R V
| author name = Bynum R
| author affiliation = Shine Medical Technologies, Inc
| author affiliation = Shine Medical Technologies, Inc
| addressee name =  
| addressee name =  
Line 14: Line 14:
| page count = 1
| page count = 1
}}
}}
=Text=
{{#Wiki_filter:Chapter 8 - Electrical Power Systems Emergency Electrical Power Systems SHINE Medical Technologies Rev. 0 Figure 8a2.2 One-Line Diagram - Uninterruptible Electrical Power Supply System 250V DC DISTRIBUTION PANEL A, CLASS 1E UPS A CLASS 1E 250V DC CLASS 1E BATTERY A CLASS 1E BATTERY CHARGER A 480V-208Y/120V 3Ø, 4W, 60 Hz
+/- 0.5%
VOLTAGE REGULATING TRANSFORMER A BUS A VOLTAGE REGULATING XFMR ASSEMBLY A CLASS 1E 250V DC DISTRIBUTION PANEL B, CLASS 1E UPS B CLASS 1E NON-CLASS 1E LEGEND:
NON-CLASS 1E TO CLASS 1E ISOLATOR 250V DC CLASS 1E BATTERY B CLASS 1E BATTERY CHARGER B 208Y/120V AC UPS CLASS 1E BUS B VOLTAGE REGULATING XFMR ASSEMBLY B CLASS 1E DISCHARGE TEST FACILITY 480V AC SDG BUS DISCHARGE TEST FACILITY 480V AC SDG BUS NON-CLASS 1E INVERTER AC THYRISTOR SWITCH MANUAL BYPASS INVERTER AC THYRISTOR SWITCH MANUAL BYPASS FACILITY ONE-LINE DIAGRAM DRAWING NUMBER LATER 480V-208Y/120V 3Ø, 4W, 60 Hz
+/- 0.5%
VOLTAGE REGULATING TRANSFORMER B}}

Latest revision as of 14:21, 10 January 2025

Shine Medical Technologies V. 0 - Chapter 08 - Figure 8a2.2-001
ML15043A366
Person / Time
Site: SHINE Medical Technologies
Issue date: 02/06/2015
From: Bynum R
Shine Medical Technologies
To:
Office of Nuclear Reactor Regulation
Lynch S
References
SHINE, SHINE.SUBMISSION.8, SHN.PSAR.P, SHN.PSAR.P.3
Download: ML15043A366 (1)


Text

Chapter 8 - Electrical Power Systems Emergency Electrical Power Systems SHINE Medical Technologies Rev. 0 Figure 8a2.2 One-Line Diagram - Uninterruptible Electrical Power Supply System 250V DC DISTRIBUTION PANEL A, CLASS 1E UPS A CLASS 1E 250V DC CLASS 1E BATTERY A CLASS 1E BATTERY CHARGER A 480V-208Y/120V 3Ø, 4W, 60 Hz

+/- 0.5%

VOLTAGE REGULATING TRANSFORMER A BUS A VOLTAGE REGULATING XFMR ASSEMBLY A CLASS 1E 250V DC DISTRIBUTION PANEL B, CLASS 1E UPS B CLASS 1E NON-CLASS 1E LEGEND:

NON-CLASS 1E TO CLASS 1E ISOLATOR 250V DC CLASS 1E BATTERY B CLASS 1E BATTERY CHARGER B 208Y/120V AC UPS CLASS 1E BUS B VOLTAGE REGULATING XFMR ASSEMBLY B CLASS 1E DISCHARGE TEST FACILITY 480V AC SDG BUS DISCHARGE TEST FACILITY 480V AC SDG BUS NON-CLASS 1E INVERTER AC THYRISTOR SWITCH MANUAL BYPASS INVERTER AC THYRISTOR SWITCH MANUAL BYPASS FACILITY ONE-LINE DIAGRAM DRAWING NUMBER LATER 480V-208Y/120V 3Ø, 4W, 60 Hz

+/- 0.5%

VOLTAGE REGULATING TRANSFORMER B