ENS 57034: Difference between revisions

From kanterella
Jump to navigation Jump to search
(StriderTol Bot insert)
 
(StriderTol Bot change)
 
Line 21: Line 21:
The storage location of the active unit is Merritt Island, FL. The failure to comply is an isolated incident affecting one AOS-100A package which is certified and is currently in service. The remaining units are not in service.
The storage location of the active unit is Merritt Island, FL. The failure to comply is an isolated incident affecting one AOS-100A package which is certified and is currently in service. The remaining units are not in service.
AOS has initiated a corrective action plan that will identify the issue, begin the internal investigation process to determine the cause, and identify any additional corrective actions. This investigation is currently in progress.
AOS has initiated a corrective action plan that will identify the issue, begin the internal investigation process to determine the cause, and identify any additional corrective actions. This investigation is currently in progress.
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2024/20240319en.html#en57034
| URL = https://www.nrc.gov/reading-rm/doc-collections/event-status/event/2024/20240320en.html#en57034
}}
}}


{{ENS-Nav}}
{{ENS-Nav}}

Latest revision as of 06:30, 20 March 2024

ENS 57034 +/-
Where
Alpha- Omega Services
Bellflower, California (NRC Region 4)
License number: PXB6.18
Organization: Alpha-Omega Services
Reporting
10 CFR 21.21(d)(3)(i), Failure to Comply or Defect
Time - Person (Reporting Time:+751.25 h31.302 days <br />4.472 weeks <br />1.029 months <br />)
Opened: Troy Hedger
13:15 Mar 18, 2024
NRC Officer: Karen Cotton-Gross
Last Updated: Mar 18, 2024
57034 - NRC Website