ML19263A849: Difference between revisions

From kanterella
Jump to navigation Jump to search
(Created page by program invented by StriderTol)
 
(Created page by program invented by StriderTol)
 
Line 21: Line 21:
| number = ML19263A858
| number = ML19263A858
| issue date = 12/27/1978
| issue date = 12/27/1978
| title = Forwards LER 78-097/01X-1
| title = LER 78-097/01X-1 on 781215:during Instrument Surveillance Procedure F-ISP 10,the 8 Temp Switches Associated W/ Isolation of HPCI Sys Steam Line Were Set Above Tech Spec Limits.Caused by Use of Wrong Conversion Table
| author name = Childs W
| author name = Childs W
| author affiliation = POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
| author affiliation = POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK

Latest revision as of 10:31, 23 January 2020

Forwards LER 78-097/01X-1
Date released: 10/08/2019 Download: ML19263A849


Forwards LER 78-097/01X-1
ML19267A268
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 12/27/1978
From: Leonard J
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19267A268 (1)
LER 78-097/01X-1 on 781215:during Instrument Surveillance Procedure F-ISP 10,the 8 Temp Switches Associated W/ Isolation of HPCI Sys Steam Line Were Set Above Tech Spec Limits.Caused by Use of Wrong Conversion Table
ML19263A858
Person / Time
Site: FitzPatrick Constellation icon.png
Issue date: 12/27/1978
From: W. Verne Childs
POWER AUTHORITY OF THE STATE OF NEW YORK (NEW YORK
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML19263A858 (2)