ML17250A501: Difference between revisions
Jump to navigation
Jump to search
StriderTol (talk | contribs) (Created page by program invented by StriderTol) |
StriderTol (talk | contribs) (StriderTol Bot change) |
||
Line 6: | Line 6: | ||
| number = ML17261A220 | | number = ML17261A220 | ||
| issue date = 08/05/1980 | | issue date = 08/05/1980 | ||
| title = | | title = Revised LER 79-023/01X-1:on 791207,during Inservice Insp, Liquid Penetrant Examination of Pressurizer nozzle-to-safe- End Weld Showed Linear Indications.Caused by Inadequate Delta Ferrite Content & Geometric Discontinuity | ||
| author name = Curtis A | | author name = Curtis A | ||
| author affiliation = ROCHESTER GAS & ELECTRIC CORP. | | author affiliation = ROCHESTER GAS & ELECTRIC CORP. |
Latest revision as of 03:36, 8 March 2020
Date released: 04/30/2018 | Download: ML17250A501 |
---|---|
ML17261A220 | |
Person / Time | |
---|---|
Site: | Ginna |
Issue date: | 08/05/1980 |
From: | Curtis A ROCHESTER GAS & ELECTRIC CORP. |
To: | NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
References | |
Download: ML17261A220 (8) | |
ML17250A500 | |
Person / Time | |
---|---|
Site: | Ginna |
Issue date: | 08/05/1980 |
From: | White L ROCHESTER GAS & ELECTRIC CORP. |
To: | GRIER B H NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
References | |
Download: ML17250A500 (2) | |