ML17250A501

From kanterella
Jump to navigation Jump to search
Forwards Revised LER 79-023/01X-1
Date released: 04/30/2018 Download: ML17250A501


Revised LER 79-023/01X-1:on 791207,during Inservice Insp, Liquid Penetrant Examination of Pressurizer nozzle-to-safe- End Weld Showed Linear Indications.Caused by Inadequate Delta Ferrite Content & Geometric Discontinuity
ML17261A220
Person / Time
Site: Ginna 
Issue date: 08/05/1980
From: Curtis A
ROCHESTER GAS & ELECTRIC CORP.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML17261A220 (8)
Forwards Revised LER 79-023/01X-1
ML17250A500
Person / Time
Site: Ginna 
Issue date: 08/05/1980
From: White L
ROCHESTER GAS & ELECTRIC CORP.
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML17250A500 (2)