| title = | | title = LER 98-006-00:on 980507,determined That Plant Was Outside Design Basis Due to SI Discharge Check Valve Reverse Flow. Check Valve Was Disassembled,Examined & Reassembled, Whereupon Valve Met Acceptance Criteria | ||
| author name = Marks D | | author name = Marks D | ||
| author affiliation = ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR | | author affiliation = ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR |
Latest revision as of 10:56, 7 March 2020
Date released: 07/31/2018 | Download: ML17313A412 |
---|---|
ML17313A413 | |
Person / Time | |
---|---|
Site: | Palo Verde ![]() |
Issue date: | 06/05/1998 |
From: | Marks D ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR |
To: | |
References | |
Download: ML17313A413 (16) | |
ML17313A411 | |
Person / Time | |
---|---|
Site: | Palo Verde ![]() |
Issue date: | 06/05/1998 |
From: | Ide W ARIZONA PUBLIC SERVICE CO. (FORMERLY ARIZONA NUCLEAR |
To: | NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM) |
References | |