Line 6: Line 6:
| number = ML18113A760
| number = ML18113A760
| issue date = 01/02/1979
| issue date = 01/02/1979
| title = Forwards LER 78-045/03L-0,78-046/03L-0 & 78-049/03L-0
| title = LER 78-049/03L-0 on 781219:conduct of PT-39B Revealed 2 Snubbers W/Fluid Levels Less than Target Level.Caused by Leaking Tube Fittings
| author name = BAUCOM T L
| author name = Baucom T
| author affiliation = VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
| author affiliation = VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
| addressee name =  
| addressee name =  
Line 21: Line 21:
| number = ML18113A759
| number = ML18113A759
| issue date = 01/02/1979
| issue date = 01/02/1979
| title = Forwards LER 78-045/03L-0,78-046/03L-0 & 78-049/03L-0
| title = LER 78-046/03L-0 on 781211:during Routine Surveillance, Discovered Failure of Heat Tracing Circuit 25A (Panel 2) Unit 1 Boron Injection Tank Recirculation to Boric Acid Tank.Caused by Boric Acid Attack on Heat Tracing Circuit
| author name = BAUCOM T L
| author name = Baucom T
| author affiliation = VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
| author affiliation = VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
| addressee name =  
| addressee name =  
Line 36: Line 36:
| number = ML18113A758
| number = ML18113A758
| issue date = 01/02/1979
| issue date = 01/02/1979
| title = Forwards LER 78-045/03L-0,78-046/03L-0 & 78-049/03L-0
| title = LER 78-045/03L-0 on 781205:radiation recorder,RR-175,stopped Printing.Caused by Frozen Bushing in Print Mechanism
| author name = BAUCOM T L
| author name = Baucom T
| author affiliation = VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
| author affiliation = VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
| addressee name =  
| addressee name =  
Line 52: Line 52:
| issue date = 01/04/1979
| issue date = 01/04/1979
| title = Forwards LER 78-045/03L-0,78-046/03L-0 & 78-049/03L-0
| title = Forwards LER 78-045/03L-0,78-046/03L-0 & 78-049/03L-0
| author name = STALLINGS C M
| author name = Stallings C
| author affiliation = VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
| author affiliation = VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
| addressee name = OREILLY J P
| addressee name = OREILLY J P

Latest revision as of 15:56, 25 January 2020

Forwards LER 78-045/03L-0,78-046/03L-0 & 78-049/03L-0
Date released: 12/10/2018 Download: ML18113A757


LER 78-049/03L-0 on 781219:conduct of PT-39B Revealed 2 Snubbers W/Fluid Levels Less than Target Level.Caused by Leaking Tube Fittings
ML18113A760
Person / Time
Site: Surry Dominion icon.png
Issue date: 01/02/1979
From: Baucom T
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18113A760 (2)
LER 78-046/03L-0 on 781211:during Routine Surveillance, Discovered Failure of Heat Tracing Circuit 25A (Panel 2) Unit 1 Boron Injection Tank Recirculation to Boric Acid Tank.Caused by Boric Acid Attack on Heat Tracing Circuit
ML18113A759
Person / Time
Site: Surry Dominion icon.png
Issue date: 01/02/1979
From: Baucom T
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18113A759 (2)
LER 78-045/03L-0 on 781205:radiation recorder,RR-175,stopped Printing.Caused by Frozen Bushing in Print Mechanism
ML18113A758
Person / Time
Site: Surry Dominion icon.png
Issue date: 01/02/1979
From: Baucom T
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18113A758 (2)
Forwards LER 78-045/03L-0,78-046/03L-0 & 78-049/03L-0
ML18113A756
Person / Time
Site: Surry Dominion icon.png
Issue date: 01/04/1979
From: Stallings C
VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.)
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML18113A756 (1)