{{#Wiki_filter:}}
{{#Wiki_filter:/200 Exelon WayKennett Square, PA 19348www.exeloncorp.comExel~o Generation10 CER 50.71 (e)(4)10 CFR 54.37(b)NEI 99-04September 14, 2015U.S. Nuclear Regulatory CommissionATTN: Document Control DeskWashington, DC 20555-0001Calvert Cliffs Nuclear Power Plant, Units 1 and 2Renewed Facility Operating License Nos. DPR-53 and DPR-69NRC Docket Nos. 50-317 and 50-318
 
==SUBJECT:==
Submittal of Updated Final Safety Analysis Report, Revision 48In accordance with 10 CFR 50.71 (e)(4) and 10 CFR 50.4(b)(6), enclosed is Revision 48 ofthe Updated Final Safety Analysis Report (UFSAR) for Calvert Cliffs Nuclear Power Plant(CCNPP). The enclosed UFSAR revision is being provided to the U.S. Nuclear RegulatoryCommission (NRC) in electronic format on CD-ROM. The electronic version of the UFSARrevision is being submitted in entirety and is a complete document.10 CFR 50.71 (e)(4) stipulates subsequent revisions must be filed annually or 6 months aftereach refueling outage provided the interval between successive updates does not exceed24 months and the revisions must reflect all changes up to a maximum of 6 months prior tothe date of filling. Revision 48 of the UFSAR incorporates applicable changes for therequired updating period. The previous revision (i.e., Revision 47) of the CCNPP wassubmitted on September 19, 2014.Attachment 1 provides a brief summary of the changes incorporated into UFSAR Revision 48.Attachment 2 includes file directory structure information identifying directory path, filename,and size of the individual files on the enclosed CD.In addition, pursuant to the requirements of 10 CFR 54.37(b) and the guidance specified inRegulatory Issue Summary 2007-1 6, Revision 1, "Implementation of the Requirements of10 CFR 54.37(b) for Holders of Renewed Licenses, "the UFSAR update required by10 CFR 50.71 (e) must include any Structures, Systems, or Components (SSCs) newlyidentified that would have been subject to an aging management review or evaluation oftime-limited aging analyses in accordance with 10 CFR 54.21. The UFSAR update mustdescribe how the licensee will manage the effects of aging in order to effectively maintainthe intended function(s) of newly-identified SSCs. An evaluation was completed todetermine whether any newly-identified SSCs existed in support of submitting UFSARRevision 48 for CON PP, Units 1 and 2. As a result of this evaluation, there were no newly-identified SSCs for which aging management reviews or time-limited aging analyses wouldapply.
KU.S. Nuclear Regulatory CommissionSubmittal of CCNPP UFSAR Revision 48NRC Docket Nos. 50-317 and 50-318September 14, 2015Page 2Furthermore, in accordance with the guidance NEI 99-04, "Guidelines for Mana ging NRCCommitment Changes," this submittal addresses commitment changes made since theprevious UFSAR submittal on September 19, 2014. There are no commitment changesbeing reported in conjunction with this submittal.As required by 10OCFR50.71 (e)(2)(i), I certify that to the best of my knowledge, Revision 48of the UFSAR accurately reflects information and analyses submitted to the NRC, orprepared pursuant to NRC requirements as described above.If you have any questions or require further information, please contact Richard Gropp at(610) 765-5557.Resp4ctfully' ,,,jDavid T. GudgerManager, Licensing and Regulatory AffairsExelon Generation Company, LLCAttachments: Attachment 1 -Brief Summary of the ChangesAttachment 2 -Electronic File Directory Structure
 
==Enclosure:==
CCNPS, Units 1 and 2, UFSAR Revision 48 (CD-ROM)cc: Regional Administrator, Region I, USNRC w/ Enclosure/AttachmentsUSNRC Senior Resident Inspector, CCNPP"USNRC Senior Project Manager NRR, CCNPP"S. T. Gray, State of Maryland"  Brief Summary of the ChangesPage 1 of 1Change NumberBrief Description of ChangeUCR00789UCR0081 6UCR00850...U CR00861 ..UCR00866UCR00867UCR00868UCR00870UCR00872...U.C.R.0.08735UCR00877UCR00883UCR00884U CR00884UCR00886UCR00887UC008UCR00891UCR00892...U.CRO00893.UCR00894UCR00896UCR00898UCR00902UCR.0.091 9UCR00921*Update UFSAR Section 7.5.7 (Seismic Instrumentation) to remove seismic................... tr.....i .ggers 0-Y:.S-001 .an~d o.-YS-0(02 an~d..seismic!* playb~ack! ..............................*Add description for new UFSAR Section 16.3.4 Reactor Pressure Vessel.... iToughnh ess R equirem enlts.: ................... ....... .. ..... ........ .. .Revise UFSAR Section 7.4.5 to describe changes in the Feedwater control............................sys~te~m and..Steam ...Gen~erator..feed Revise UFSAR Sections 7.10.2 and 14.4 related to Excess Load event......Revise description in UFSAR Table 16-2 for Line Item 189............................R evis~e descri.Ptior.n , in U FSA R .Table .254., ...............................................Revise UFSAR Section 11.2.3.1 and Table 11-11 to reflect changes related toarea radiation monitors..........................."Revi se UFJSARnTabl}e 9-20oto adda "note to allow d ifferent pipin g 'materi al andi............Revise UFSAR Table 11-10 to reflect changes in the display for the Main SteamLine radiation monitors.......................... ..R~evise descrip~tio in. n UF.SAR T. abl!e...1.6-2 f.or L~ine..Item .21.6 ..... .................................SAdd description for new UFSAR Section 16.3.1 Containment Tendon PrestressSLoss and update various line items in Table 16-2. ....................... Revise UFSAR S-ection 8.4.44related to the installation of a new Automatic...........................................Ad~d description..f~ornew. UFISAR. Sect~ion... 16..3.2...poisoQn..Sheets in spent..Fuel. Pool.'.Add description for new UFSAR Section 16.3.3 10 CER 50.49 Environmental.. ....:Q ualification P!rogram ....... .... .... ... ......................Revise UF~sAR Table 9-18 concerning maintaining Diesel-Generator Room... ..*temperature.SUpdate UFSAR Sections 3.3, 3.4, 3.5, and 3.7 to include information for Unit 2(Cycle 21 ) fuel batch and burnable poison data, cycle limiting values and excessshutdown margin, quarter core assembly map, relative power densities at...... .................. d ~iff[ e re n t. c o£ n d itio n s .*.......................... ........ ......... .. .. ..... ... .. .... .......... ..... .... .................SUpdate UFSAR Sections 7.5.4 and 7.5.5 related Plant Process Computer..........................i..Revi~s~e.descripltionD in UF).SA.R. Tabl.e 1.6-.2_.0 forline.Item 1!56. .................... ......... ....Revise UFSAR Section 7.4.7.2 description related to Turbine high exhaust..................... .. .e p e a u e trte m p e ra tu re.... .. ...... ........ .............. .. ........ ........trip .... ...... ............Revise UFSAR Sections 14.13, 14.14, and 14.17 for Unit 2 Cycle 21 concerninguse of AREVA fuel.Revise UFSAR Section 8.4 description regarding diesel fuel oil calculation..... ..... ......... ... m e h o * ... ........ .........me th o d ..... .. .. ...... ........... .... .............. ......... .. .. ...Revise UFSAR to add new information in Section 9.3.2.1 (Circulating Water........ ......... ... ... .y ~ e ) ,... .... .. ........Sy s t e m ) ...... ........ .. ............ .. ... .. ...... ...... .... .. ... .......... .... ....... .... ....... .. ............. .............................. Revise UFSAR. Section 5A.3_.5. (Referen~ces). to? correct a date reference ...........SRevise various UFSAR sections and LOEP references to make editorialcorrections.
.ATTACHMENT 2 Page ilof 1Electronic File Directory StructureI :C FA 4 0 1Intro and Summary.pdf ___ 439,7721jUFSAR R48 :002 01 Intro and Summary Fig.pdf ____9,068,1151d:\C UFSR R4 00 02 ite nd Evirnmenpdfg i54ij 3{j~d:\CC UFSAR R48 :003 02 Site and EnvironmentFg.pdf ______ -Sd:\CC UFSAR R48 005 03 Reactor.pdf _____1,021,0751d:\CC UFSAR R48 :006 03 Reactor Fig.pdf i ,5" 118 '278i;d:\CC UFA 4 0 4RSand Associated Sys.pdf i5719id:\CUFAR t R48008 04 RCS and Associated Sys Fig.pdf ... .................. ..1,294,7091td:\CC UFSAR R48 00 5Structures.pdf '5975d:CC USA 48 1010 05 Structures Figpdfdf,762,22d:\CC UFSAR R48 0611 05 Structures App.pdf .____ 526,778 1i d:\CCUFSAR R48 1012 05 Structures App Fig.pdf 1 752,4021d:\CC UFSAR R48 ]015 07 lnstr and Controls.pdf __ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _679,439!d\CUARR48 1016 07 Instr and Controls Fig.pdf 3,142,6181UFSAR R48 __ 017 08 Electrical Sys.pdf ................ ....................................349,60tU4d:CC UFSAR R48 [018 08 Electrical Sys Fig.pdf ___- 2,927,2881Id:\CC UFSAR R48 i019 09 Auxiliary Systems.pdf ____675,9861UFSAR R48 1020 09 Auxiliary Systems Fig.pdf ___ __ 4,610,1731d:\CC UFSAR R48 02 0Steam and Power Conv.pdf ,135,6691id:\CC UFSAR R48 022 10 Steam and Power Cony Fig.pdf i4,382,1371d:\CC UFSAR R48 :023 11 Waste Processing and RP.pdf ___ ____ __ d:\CC UFSAR R48 024 11 Waste Processing and RP Fig.pdf _____3,458,674td:\ccUFSAR R48 ~ 025 12 Conduct of Operations.pdf i13741731rd:\CC UFSAR R48 1026 12 Conduct of Operations Fig.pdf 183,564!'d:\CC UFSAR R48 13 Initial Tests and Operation.pdf _____110,5081!d:\CC UFSAR R48 j028§14 Safety Analysis.pdf ___ 1,280,677Sd:\CC UFSAR R48 1029 14 Safety AnalysisFig.pdf 3,774,1021d:\CC UFSAR R48 030 15Technical Req Manual.pdf _ 71,877d:CUFAR4 031 Li cense Renewal.pdf ___________ __ 401,930~
ENCLOSURECalvert Cliffs Nuclear Power PlantUnits 1 and 2Updated Final Safety Analysis Report, Revision 48Compact Disk (CD)
/200 Exelon WayKennett Square, PA 19348www.exeloncorp.comExel~o Generation10 CER 50.71 (e)(4)10 CFR 54.37(b)NEI 99-04September 14, 2015U.S. Nuclear Regulatory CommissionATTN: Document Control DeskWashington, DC 20555-0001Calvert Cliffs Nuclear Power Plant, Units 1 and 2Renewed Facility Operating License Nos. DPR-53 and DPR-69NRC Docket Nos. 50-317 and 50-318
 
==SUBJECT:==
Submittal of Updated Final Safety Analysis Report, Revision 48In accordance with 10 CFR 50.71 (e)(4) and 10 CFR 50.4(b)(6), enclosed is Revision 48 ofthe Updated Final Safety Analysis Report (UFSAR) for Calvert Cliffs Nuclear Power Plant(CCNPP). The enclosed UFSAR revision is being provided to the U.S. Nuclear RegulatoryCommission (NRC) in electronic format on CD-ROM. The electronic version of the UFSARrevision is being submitted in entirety and is a complete document.10 CFR 50.71 (e)(4) stipulates subsequent revisions must be filed annually or 6 months aftereach refueling outage provided the interval between successive updates does not exceed24 months and the revisions must reflect all changes up to a maximum of 6 months prior tothe date of filling. Revision 48 of the UFSAR incorporates applicable changes for therequired updating period. The previous revision (i.e., Revision 47) of the CCNPP wassubmitted on September 19, 2014.Attachment 1 provides a brief summary of the changes incorporated into UFSAR Revision 48.Attachment 2 includes file directory structure information identifying directory path, filename,and size of the individual files on the enclosed CD.In addition, pursuant to the requirements of 10 CFR 54.37(b) and the guidance specified inRegulatory Issue Summary 2007-1 6, Revision 1, "Implementation of the Requirements of10 CFR 54.37(b) for Holders of Renewed Licenses, "the UFSAR update required by10 CFR 50.71 (e) must include any Structures, Systems, or Components (SSCs) newlyidentified that would have been subject to an aging management review or evaluation oftime-limited aging analyses in accordance with 10 CFR 54.21. The UFSAR update mustdescribe how the licensee will manage the effects of aging in order to effectively maintainthe intended function(s) of newly-identified SSCs. An evaluation was completed todetermine whether any newly-identified SSCs existed in support of submitting UFSARRevision 48 for CON PP, Units 1 and 2. As a result of this evaluation, there were no newly-identified SSCs for which aging management reviews or time-limited aging analyses wouldapply.
KU.S. Nuclear Regulatory CommissionSubmittal of CCNPP UFSAR Revision 48NRC Docket Nos. 50-317 and 50-318September 14, 2015Page 2Furthermore, in accordance with the guidance NEI 99-04, "Guidelines for Mana ging NRCCommitment Changes," this submittal addresses commitment changes made since theprevious UFSAR submittal on September 19, 2014. There are no commitment changesbeing reported in conjunction with this submittal.As required by 10OCFR50.71 (e)(2)(i), I certify that to the best of my knowledge, Revision 48of the UFSAR accurately reflects information and analyses submitted to the NRC, orprepared pursuant to NRC requirements as described above.If you have any questions or require further information, please contact Richard Gropp at(610) 765-5557.Resp4ctfully' ,,,jDavid T. GudgerManager, Licensing and Regulatory AffairsExelon Generation Company, LLCAttachments: Attachment 1 -Brief Summary of the ChangesAttachment 2 -Electronic File Directory Structure
 
==Enclosure:==
CCNPS, Units 1 and 2, UFSAR Revision 48 (CD-ROM)cc: Regional Administrator, Region I, USNRC w/ Enclosure/AttachmentsUSNRC Senior Resident Inspector, CCNPP"USNRC Senior Project Manager NRR, CCNPP"S. T. Gray, State of Maryland"  Brief Summary of the ChangesPage 1 of 1Change NumberBrief Description of ChangeUCR00789UCR0081 6UCR00850...U CR00861 ..UCR00866UCR00867UCR00868UCR00870UCR00872...U.C.R.0.08735UCR00877UCR00883UCR00884U CR00884UCR00886UCR00887UC008UCR00891UCR00892...U.CRO00893.UCR00894UCR00896UCR00898UCR00902UCR.0.091 9UCR00921*Update UFSAR Section 7.5.7 (Seismic Instrumentation) to remove seismic................... tr.....i .ggers 0-Y:.S-001 .an~d o.-YS-0(02 an~d..seismic!* playb~ack! ..............................*Add description for new UFSAR Section 16.3.4 Reactor Pressure Vessel.... iToughnh ess R equirem enlts.: ................... ....... .. ..... ........ .. .Revise UFSAR Section 7.4.5 to describe changes in the Feedwater control............................sys~te~m and..Steam ...Gen~erator..feed Revise UFSAR Sections 7.10.2 and 14.4 related to Excess Load event......Revise description in UFSAR Table 16-2 for Line Item 189............................R evis~e descri.Ptior.n , in U FSA R .Table .254., ...............................................Revise UFSAR Section 11.2.3.1 and Table 11-11 to reflect changes related toarea radiation monitors..........................."Revi se UFJSARnTabl}e 9-20oto adda "note to allow d ifferent pipin g 'materi al andi............Revise UFSAR Table 11-10 to reflect changes in the display for the Main SteamLine radiation monitors.......................... ..R~evise descrip~tio in. n UF.SAR T. abl!e...1.6-2 f.or L~ine..Item .21.6 ..... .................................SAdd description for new UFSAR Section 16.3.1 Containment Tendon PrestressSLoss and update various line items in Table 16-2. ....................... Revise UFSAR S-ection 8.4.44related to the installation of a new Automatic...........................................Ad~d description..f~ornew. UFISAR. Sect~ion... 16..3.2...poisoQn..Sheets in spent..Fuel. Pool.'.Add description for new UFSAR Section 16.3.3 10 CER 50.49 Environmental.. ....:Q ualification P!rogram ....... .... .... ... ......................Revise UF~sAR Table 9-18 concerning maintaining Diesel-Generator Room... ..*temperature.SUpdate UFSAR Sections 3.3, 3.4, 3.5, and 3.7 to include information for Unit 2(Cycle 21 ) fuel batch and burnable poison data, cycle limiting values and excessshutdown margin, quarter core assembly map, relative power densities at...... .................. d ~iff[ e re n t. c o£ n d itio n s .*.......................... ........ ......... .. .. ..... ... .. .... .......... ..... .... .................SUpdate UFSAR Sections 7.5.4 and 7.5.5 related Plant Process Computer..........................i..Revi~s~e.descripltionD in UF).SA.R. Tabl.e 1.6-.2_.0 forline.Item 1!56. .................... ......... ....Revise UFSAR Section 7.4.7.2 description related to Turbine high exhaust..................... .. .e p e a u e trte m p e ra tu re.... .. ...... ........ .............. .. ........ ........trip .... ...... ............Revise UFSAR Sections 14.13, 14.14, and 14.17 for Unit 2 Cycle 21 concerninguse of AREVA fuel.Revise UFSAR Section 8.4 description regarding diesel fuel oil calculation..... ..... ......... ... m e h o * ... ........ .........me th o d ..... .. .. ...... ........... .... .............. ......... .. .. ...Revise UFSAR to add new information in Section 9.3.2.1 (Circulating Water........ ......... ... ... .y ~ e ) ,... .... .. ........Sy s t e m ) ...... ........ .. ............ .. ... .. ...... ...... .... .. ... .......... .... ....... .... ....... .. ............. .............................. Revise UFSAR. Section 5A.3_.5. (Referen~ces). to? correct a date reference ...........SRevise various UFSAR sections and LOEP references to make editorialcorrections.
.ATTACHMENT 2 Page ilof 1Electronic File Directory StructureI :C FA 4 0 1Intro and Summary.pdf ___ 439,7721jUFSAR R48 :002 01 Intro and Summary Fig.pdf ____9,068,1151d:\C UFSR R4 00 02 ite nd Evirnmenpdfg i54ij 3{j~d:\CC UFSAR R48 :003 02 Site and EnvironmentFg.pdf ______ -Sd:\CC UFSAR R48 005 03 Reactor.pdf _____1,021,0751d:\CC UFSAR R48 :006 03 Reactor Fig.pdf i ,5" 118 '278i;d:\CC UFA 4 0 4RSand Associated Sys.pdf i5719id:\CUFAR t R48008 04 RCS and Associated Sys Fig.pdf ... .................. ..1,294,7091td:\CC UFSAR R48 00 5Structures.pdf '5975d:CC USA 48 1010 05 Structures Figpdfdf,762,22d:\CC UFSAR R48 0611 05 Structures App.pdf .____ 526,778 1i d:\CCUFSAR R48 1012 05 Structures App Fig.pdf 1 752,4021d:\CC UFSAR R48 ]015 07 lnstr and Controls.pdf __ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _679,439!d\CUARR48 1016 07 Instr and Controls Fig.pdf 3,142,6181UFSAR R48 __ 017 08 Electrical Sys.pdf ................ ....................................349,60tU4d:CC UFSAR R48 [018 08 Electrical Sys Fig.pdf ___- 2,927,2881Id:\CC UFSAR R48 i019 09 Auxiliary Systems.pdf ____675,9861UFSAR R48 1020 09 Auxiliary Systems Fig.pdf ___ __ 4,610,1731d:\CC UFSAR R48 02 0Steam and Power Conv.pdf ,135,6691id:\CC UFSAR R48 022 10 Steam and Power Cony Fig.pdf i4,382,1371d:\CC UFSAR R48 :023 11 Waste Processing and RP.pdf ___ ____ __ d:\CC UFSAR R48 024 11 Waste Processing and RP Fig.pdf _____3,458,674td:\ccUFSAR R48 ~ 025 12 Conduct of Operations.pdf i13741731rd:\CC UFSAR R48 1026 12 Conduct of Operations Fig.pdf 183,564!'d:\CC UFSAR R48 13 Initial Tests and Operation.pdf _____110,5081!d:\CC UFSAR R48 j028§14 Safety Analysis.pdf ___ 1,280,677Sd:\CC UFSAR R48 1029 14 Safety AnalysisFig.pdf 3,774,1021d:\CC UFSAR R48 030 15Technical Req Manual.pdf _ 71,877d:CUFAR4 031 Li cense Renewal.pdf ___________ __ 401,930~
ENCLOSURECalvert Cliffs Nuclear Power PlantUnits 1 and 2Updated Final Safety Analysis Report, Revision 48Compact Disk (CD)}}

Revision as of 05:16, 6 June 2018

Calvert Cliffs, Units 1 & 2, Submittal of Updated Final Safety Analysis Report, Revision 48
ML15279A467
Person / Time
Site:  Constellation icon.png
Issue date: 09/14/2015
From: David Gudger
Exelon Generation Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
Shared Package
ML15279A292 List:
References
NEI 99-04
Download: ML15279A467 (5)


Text

/200 Exelon WayKennett Square, PA 19348www.exeloncorp.comExel~o Generation10 CER 50.71 (e)(4)10 CFR 54.37(b)NEI 99-04September 14, 2015U.S. Nuclear Regulatory CommissionATTN: Document Control DeskWashington, DC 20555-0001Calvert Cliffs Nuclear Power Plant, Units 1 and 2Renewed Facility Operating License Nos. DPR-53 and DPR-69NRC Docket Nos. 50-317 and 50-318

SUBJECT:

Submittal of Updated Final Safety Analysis Report, Revision 48In accordance with 10 CFR 50.71 (e)(4) and 10 CFR 50.4(b)(6), enclosed is Revision 48 ofthe Updated Final Safety Analysis Report (UFSAR) for Calvert Cliffs Nuclear Power Plant(CCNPP). The enclosed UFSAR revision is being provided to the U.S. Nuclear RegulatoryCommission (NRC) in electronic format on CD-ROM. The electronic version of the UFSARrevision is being submitted in entirety and is a complete document.10 CFR 50.71 (e)(4) stipulates subsequent revisions must be filed annually or 6 months aftereach refueling outage provided the interval between successive updates does not exceed24 months and the revisions must reflect all changes up to a maximum of 6 months prior tothe date of filling. Revision 48 of the UFSAR incorporates applicable changes for therequired updating period. The previous revision (i.e., Revision 47) of the CCNPP wassubmitted on September 19, 2014.Attachment 1 provides a brief summary of the changes incorporated into UFSAR Revision 48.Attachment 2 includes file directory structure information identifying directory path, filename,and size of the individual files on the enclosed CD.In addition, pursuant to the requirements of 10 CFR 54.37(b) and the guidance specified inRegulatory Issue Summary 2007-1 6, Revision 1, "Implementation of the Requirements of10 CFR 54.37(b) for Holders of Renewed Licenses, "the UFSAR update required by10 CFR 50.71 (e) must include any Structures, Systems, or Components (SSCs) newlyidentified that would have been subject to an aging management review or evaluation oftime-limited aging analyses in accordance with 10 CFR 54.21. The UFSAR update mustdescribe how the licensee will manage the effects of aging in order to effectively maintainthe intended function(s) of newly-identified SSCs. An evaluation was completed todetermine whether any newly-identified SSCs existed in support of submitting UFSARRevision 48 for CON PP, Units 1 and 2. As a result of this evaluation, there were no newly-identified SSCs for which aging management reviews or time-limited aging analyses wouldapply.

KU.S. Nuclear Regulatory CommissionSubmittal of CCNPP UFSAR Revision 48NRC Docket Nos. 50-317 and 50-318September 14, 2015Page 2Furthermore, in accordance with the guidance NEI 99-04, "Guidelines for Mana ging NRCCommitment Changes," this submittal addresses commitment changes made since theprevious UFSAR submittal on September 19, 2014. There are no commitment changesbeing reported in conjunction with this submittal.As required by 10OCFR50.71 (e)(2)(i), I certify that to the best of my knowledge, Revision 48of the UFSAR accurately reflects information and analyses submitted to the NRC, orprepared pursuant to NRC requirements as described above.If you have any questions or require further information, please contact Richard Gropp at(610) 765-5557.Resp4ctfully' ,,,jDavid T. GudgerManager, Licensing and Regulatory AffairsExelon Generation Company, LLCAttachments: Attachment 1 -Brief Summary of the ChangesAttachment 2 -Electronic File Directory Structure

Enclosure:

CCNPS, Units 1 and 2, UFSAR Revision 48 (CD-ROM)cc: Regional Administrator, Region I, USNRC w/ Enclosure/AttachmentsUSNRC Senior Resident Inspector, CCNPP"USNRC Senior Project Manager NRR, CCNPP"S. T. Gray, State of Maryland" Brief Summary of the ChangesPage 1 of 1Change NumberBrief Description of ChangeUCR00789UCR0081 6UCR00850...U CR00861 ..UCR00866UCR00867UCR00868UCR00870UCR00872...U.C.R.0.08735UCR00877UCR00883UCR00884U CR00884UCR00886UCR00887UC008UCR00891UCR00892...U.CRO00893.UCR00894UCR00896UCR00898UCR00902UCR.0.091 9UCR00921*Update UFSAR Section 7.5.7 (Seismic Instrumentation) to remove seismic................... tr.....i .ggers 0-Y:.S-001 .an~d o.-YS-0(02 an~d..seismic!* playb~ack! ..............................*Add description for new UFSAR Section 16.3.4 Reactor Pressure Vessel.... iToughnh ess R equirem enlts.: ................... ....... .. ..... ........ .. .Revise UFSAR Section 7.4.5 to describe changes in the Feedwater control............................sys~te~m and..Steam ...Gen~erator..feed Revise UFSAR Sections 7.10.2 and 14.4 related to Excess Load event......Revise description in UFSAR Table 16-2 for Line Item 189............................R evis~e descri.Ptior.n , in U FSA R .Table .254., ...............................................Revise UFSAR Section 11.2.3.1 and Table 11-11 to reflect changes related toarea radiation monitors..........................."Revi se UFJSARnTabl}e 9-20oto adda "note to allow d ifferent pipin g 'materi al andi............Revise UFSAR Table 11-10 to reflect changes in the display for the Main SteamLine radiation monitors.......................... ..R~evise descrip~tio in. n UF.SAR T. abl!e...1.6-2 f.or L~ine..Item .21.6 ..... .................................SAdd description for new UFSAR Section 16.3.1 Containment Tendon PrestressSLoss and update various line items in Table 16-2. ....................... Revise UFSAR S-ection 8.4.44related to the installation of a new Automatic...........................................Ad~d description..f~ornew. UFISAR. Sect~ion... 16..3.2...poisoQn..Sheets in spent..Fuel. Pool.'.Add description for new UFSAR Section 16.3.3 10 CER 50.49 Environmental.. ....:Q ualification P!rogram ....... .... .... ... ......................Revise UF~sAR Table 9-18 concerning maintaining Diesel-Generator Room... ..*temperature.SUpdate UFSAR Sections 3.3, 3.4, 3.5, and 3.7 to include information for Unit 2(Cycle 21 ) fuel batch and burnable poison data, cycle limiting values and excessshutdown margin, quarter core assembly map, relative power densities at...... .................. d ~iff[ e re n t. c o£ n d itio n s .*.......................... ........ ......... .. .. ..... ... .. .... .......... ..... .... .................SUpdate UFSAR Sections 7.5.4 and 7.5.5 related Plant Process Computer..........................i..Revi~s~e.descripltionD in UF).SA.R. Tabl.e 1.6-.2_.0 forline.Item 1!56. .................... ......... ....Revise UFSAR Section 7.4.7.2 description related to Turbine high exhaust..................... .. .e p e a u e trte m p e ra tu re.... .. ...... ........ .............. .. ........ ........trip .... ...... ............Revise UFSAR Sections 14.13, 14.14, and 14.17 for Unit 2 Cycle 21 concerninguse of AREVA fuel.Revise UFSAR Section 8.4 description regarding diesel fuel oil calculation..... ..... ......... ... m e h o * ... ........ .........me th o d ..... .. .. ...... ........... .... .............. ......... .. .. ...Revise UFSAR to add new information in Section 9.3.2.1 (Circulating Water........ ......... ... ... .y ~ e ) ,... .... .. ........Sy s t e m ) ...... ........ .. ............ .. ... .. ...... ...... .... .. ... .......... .... ....... .... ....... .. ............. .............................. Revise UFSAR. Section 5A.3_.5. (Referen~ces). to? correct a date reference ...........SRevise various UFSAR sections and LOEP references to make editorialcorrections.

.ATTACHMENT 2 Page ilof 1Electronic File Directory StructureI :C FA 4 0 1Intro and Summary.pdf ___ 439,7721jUFSAR R48 :002 01 Intro and Summary Fig.pdf ____9,068,1151d:\C UFSR R4 00 02 ite nd Evirnmenpdfg i54ij 3{j~d:\CC UFSAR R48 :003 02 Site and EnvironmentFg.pdf ______ -Sd:\CC UFSAR R48 005 03 Reactor.pdf _____1,021,0751d:\CC UFSAR R48 :006 03 Reactor Fig.pdf i ,5" 118 '278i;d:\CC UFA 4 0 4RSand Associated Sys.pdf i5719id:\CUFAR t R48008 04 RCS and Associated Sys Fig.pdf ... .................. ..1,294,7091td:\CC UFSAR R48 00 5Structures.pdf '5975d:CC USA 48 1010 05 Structures Figpdfdf,762,22d:\CC UFSAR R48 0611 05 Structures App.pdf .____ 526,778 1i d:\CCUFSAR R48 1012 05 Structures App Fig.pdf 1 752,4021d:\CC UFSAR R48 ]015 07 lnstr and Controls.pdf __ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _679,439!d\CUARR48 1016 07 Instr and Controls Fig.pdf 3,142,6181UFSAR R48 __ 017 08 Electrical Sys.pdf ................ ....................................349,60tU4d:CC UFSAR R48 [018 08 Electrical Sys Fig.pdf ___- 2,927,2881Id:\CC UFSAR R48 i019 09 Auxiliary Systems.pdf ____675,9861UFSAR R48 1020 09 Auxiliary Systems Fig.pdf ___ __ 4,610,1731d:\CC UFSAR R48 02 0Steam and Power Conv.pdf ,135,6691id:\CC UFSAR R48 022 10 Steam and Power Cony Fig.pdf i4,382,1371d:\CC UFSAR R48 :023 11 Waste Processing and RP.pdf ___ ____ __ d:\CC UFSAR R48 024 11 Waste Processing and RP Fig.pdf _____3,458,674td:\ccUFSAR R48 ~ 025 12 Conduct of Operations.pdf i13741731rd:\CC UFSAR R48 1026 12 Conduct of Operations Fig.pdf 183,564!'d:\CC UFSAR R48 13 Initial Tests and Operation.pdf _____110,5081!d:\CC UFSAR R48 j028§14 Safety Analysis.pdf ___ 1,280,677Sd:\CC UFSAR R48 1029 14 Safety AnalysisFig.pdf 3,774,1021d:\CC UFSAR R48 030 15Technical Req Manual.pdf _ 71,877d:CUFAR4 031 Li cense Renewal.pdf ___________ __ 401,930~

ENCLOSURECalvert Cliffs Nuclear Power PlantUnits 1 and 2Updated Final Safety Analysis Report, Revision 48Compact Disk (CD)

/200 Exelon WayKennett Square, PA 19348www.exeloncorp.comExel~o Generation10 CER 50.71 (e)(4)10 CFR 54.37(b)NEI 99-04September 14, 2015U.S. Nuclear Regulatory CommissionATTN: Document Control DeskWashington, DC 20555-0001Calvert Cliffs Nuclear Power Plant, Units 1 and 2Renewed Facility Operating License Nos. DPR-53 and DPR-69NRC Docket Nos. 50-317 and 50-318

SUBJECT:

Submittal of Updated Final Safety Analysis Report, Revision 48In accordance with 10 CFR 50.71 (e)(4) and 10 CFR 50.4(b)(6), enclosed is Revision 48 ofthe Updated Final Safety Analysis Report (UFSAR) for Calvert Cliffs Nuclear Power Plant(CCNPP). The enclosed UFSAR revision is being provided to the U.S. Nuclear RegulatoryCommission (NRC) in electronic format on CD-ROM. The electronic version of the UFSARrevision is being submitted in entirety and is a complete document.10 CFR 50.71 (e)(4) stipulates subsequent revisions must be filed annually or 6 months aftereach refueling outage provided the interval between successive updates does not exceed24 months and the revisions must reflect all changes up to a maximum of 6 months prior tothe date of filling. Revision 48 of the UFSAR incorporates applicable changes for therequired updating period. The previous revision (i.e., Revision 47) of the CCNPP wassubmitted on September 19, 2014.Attachment 1 provides a brief summary of the changes incorporated into UFSAR Revision 48.Attachment 2 includes file directory structure information identifying directory path, filename,and size of the individual files on the enclosed CD.In addition, pursuant to the requirements of 10 CFR 54.37(b) and the guidance specified inRegulatory Issue Summary 2007-1 6, Revision 1, "Implementation of the Requirements of10 CFR 54.37(b) for Holders of Renewed Licenses, "the UFSAR update required by10 CFR 50.71 (e) must include any Structures, Systems, or Components (SSCs) newlyidentified that would have been subject to an aging management review or evaluation oftime-limited aging analyses in accordance with 10 CFR 54.21. The UFSAR update mustdescribe how the licensee will manage the effects of aging in order to effectively maintainthe intended function(s) of newly-identified SSCs. An evaluation was completed todetermine whether any newly-identified SSCs existed in support of submitting UFSARRevision 48 for CON PP, Units 1 and 2. As a result of this evaluation, there were no newly-identified SSCs for which aging management reviews or time-limited aging analyses wouldapply.

KU.S. Nuclear Regulatory CommissionSubmittal of CCNPP UFSAR Revision 48NRC Docket Nos. 50-317 and 50-318September 14, 2015Page 2Furthermore, in accordance with the guidance NEI 99-04, "Guidelines for Mana ging NRCCommitment Changes," this submittal addresses commitment changes made since theprevious UFSAR submittal on September 19, 2014. There are no commitment changesbeing reported in conjunction with this submittal.As required by 10OCFR50.71 (e)(2)(i), I certify that to the best of my knowledge, Revision 48of the UFSAR accurately reflects information and analyses submitted to the NRC, orprepared pursuant to NRC requirements as described above.If you have any questions or require further information, please contact Richard Gropp at(610) 765-5557.Resp4ctfully' ,,,jDavid T. GudgerManager, Licensing and Regulatory AffairsExelon Generation Company, LLCAttachments: Attachment 1 -Brief Summary of the ChangesAttachment 2 -Electronic File Directory Structure

Enclosure:

CCNPS, Units 1 and 2, UFSAR Revision 48 (CD-ROM)cc: Regional Administrator, Region I, USNRC w/ Enclosure/AttachmentsUSNRC Senior Resident Inspector, CCNPP"USNRC Senior Project Manager NRR, CCNPP"S. T. Gray, State of Maryland" Brief Summary of the ChangesPage 1 of 1Change NumberBrief Description of ChangeUCR00789UCR0081 6UCR00850...U CR00861 ..UCR00866UCR00867UCR00868UCR00870UCR00872...U.C.R.0.08735UCR00877UCR00883UCR00884U CR00884UCR00886UCR00887UC008UCR00891UCR00892...U.CRO00893.UCR00894UCR00896UCR00898UCR00902UCR.0.091 9UCR00921*Update UFSAR Section 7.5.7 (Seismic Instrumentation) to remove seismic................... tr.....i .ggers 0-Y:.S-001 .an~d o.-YS-0(02 an~d..seismic!* playb~ack! ..............................*Add description for new UFSAR Section 16.3.4 Reactor Pressure Vessel.... iToughnh ess R equirem enlts.: ................... ....... .. ..... ........ .. .Revise UFSAR Section 7.4.5 to describe changes in the Feedwater control............................sys~te~m and..Steam ...Gen~erator..feed Revise UFSAR Sections 7.10.2 and 14.4 related to Excess Load event......Revise description in UFSAR Table 16-2 for Line Item 189............................R evis~e descri.Ptior.n , in U FSA R .Table .254., ...............................................Revise UFSAR Section 11.2.3.1 and Table 11-11 to reflect changes related toarea radiation monitors..........................."Revi se UFJSARnTabl}e 9-20oto adda "note to allow d ifferent pipin g 'materi al andi............Revise UFSAR Table 11-10 to reflect changes in the display for the Main SteamLine radiation monitors.......................... ..R~evise descrip~tio in. n UF.SAR T. abl!e...1.6-2 f.or L~ine..Item .21.6 ..... .................................SAdd description for new UFSAR Section 16.3.1 Containment Tendon PrestressSLoss and update various line items in Table 16-2. ....................... Revise UFSAR S-ection 8.4.44related to the installation of a new Automatic...........................................Ad~d description..f~ornew. UFISAR. Sect~ion... 16..3.2...poisoQn..Sheets in spent..Fuel. Pool.'.Add description for new UFSAR Section 16.3.3 10 CER 50.49 Environmental.. ....:Q ualification P!rogram ....... .... .... ... ......................Revise UF~sAR Table 9-18 concerning maintaining Diesel-Generator Room... ..*temperature.SUpdate UFSAR Sections 3.3, 3.4, 3.5, and 3.7 to include information for Unit 2(Cycle 21 ) fuel batch and burnable poison data, cycle limiting values and excessshutdown margin, quarter core assembly map, relative power densities at...... .................. d ~iff[ e re n t. c o£ n d itio n s .*.......................... ........ ......... .. .. ..... ... .. .... .......... ..... .... .................SUpdate UFSAR Sections 7.5.4 and 7.5.5 related Plant Process Computer..........................i..Revi~s~e.descripltionD in UF).SA.R. Tabl.e 1.6-.2_.0 forline.Item 1!56. .................... ......... ....Revise UFSAR Section 7.4.7.2 description related to Turbine high exhaust..................... .. .e p e a u e trte m p e ra tu re.... .. ...... ........ .............. .. ........ ........trip .... ...... ............Revise UFSAR Sections 14.13, 14.14, and 14.17 for Unit 2 Cycle 21 concerninguse of AREVA fuel.Revise UFSAR Section 8.4 description regarding diesel fuel oil calculation..... ..... ......... ... m e h o * ... ........ .........me th o d ..... .. .. ...... ........... .... .............. ......... .. .. ...Revise UFSAR to add new information in Section 9.3.2.1 (Circulating Water........ ......... ... ... .y ~ e ) ,... .... .. ........Sy s t e m ) ...... ........ .. ............ .. ... .. ...... ...... .... .. ... .......... .... ....... .... ....... .. ............. .............................. Revise UFSAR. Section 5A.3_.5. (Referen~ces). to? correct a date reference ...........SRevise various UFSAR sections and LOEP references to make editorialcorrections.

.ATTACHMENT 2 Page ilof 1Electronic File Directory StructureI :C FA 4 0 1Intro and Summary.pdf ___ 439,7721jUFSAR R48 :002 01 Intro and Summary Fig.pdf ____9,068,1151d:\C UFSR R4 00 02 ite nd Evirnmenpdfg i54ij 3{j~d:\CC UFSAR R48 :003 02 Site and EnvironmentFg.pdf ______ -Sd:\CC UFSAR R48 005 03 Reactor.pdf _____1,021,0751d:\CC UFSAR R48 :006 03 Reactor Fig.pdf i ,5" 118 '278i;d:\CC UFA 4 0 4RSand Associated Sys.pdf i5719id:\CUFAR t R48008 04 RCS and Associated Sys Fig.pdf ... .................. ..1,294,7091td:\CC UFSAR R48 00 5Structures.pdf '5975d:CC USA 48 1010 05 Structures Figpdfdf,762,22d:\CC UFSAR R48 0611 05 Structures App.pdf .____ 526,778 1i d:\CCUFSAR R48 1012 05 Structures App Fig.pdf 1 752,4021d:\CC UFSAR R48 ]015 07 lnstr and Controls.pdf __ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _679,439!d\CUARR48 1016 07 Instr and Controls Fig.pdf 3,142,6181UFSAR R48 __ 017 08 Electrical Sys.pdf ................ ....................................349,60tU4d:CC UFSAR R48 [018 08 Electrical Sys Fig.pdf ___- 2,927,2881Id:\CC UFSAR R48 i019 09 Auxiliary Systems.pdf ____675,9861UFSAR R48 1020 09 Auxiliary Systems Fig.pdf ___ __ 4,610,1731d:\CC UFSAR R48 02 0Steam and Power Conv.pdf ,135,6691id:\CC UFSAR R48 022 10 Steam and Power Cony Fig.pdf i4,382,1371d:\CC UFSAR R48 :023 11 Waste Processing and RP.pdf ___ ____ __ d:\CC UFSAR R48 024 11 Waste Processing and RP Fig.pdf _____3,458,674td:\ccUFSAR R48 ~ 025 12 Conduct of Operations.pdf i13741731rd:\CC UFSAR R48 1026 12 Conduct of Operations Fig.pdf 183,564!'d:\CC UFSAR R48 13 Initial Tests and Operation.pdf _____110,5081!d:\CC UFSAR R48 j028§14 Safety Analysis.pdf ___ 1,280,677Sd:\CC UFSAR R48 1029 14 Safety AnalysisFig.pdf 3,774,1021d:\CC UFSAR R48 030 15Technical Req Manual.pdf _ 71,877d:CUFAR4 031 Li cense Renewal.pdf ___________ __ 401,930~

ENCLOSURECalvert Cliffs Nuclear Power PlantUnits 1 and 2Updated Final Safety Analysis Report, Revision 48Compact Disk (CD)